• Title/Summary/Keyword: 미세 유체관

Search Result 28, Processing Time 0.024 seconds

Microfluidic Preparation of Monodisperse Multiple Emulsion using Hydrodynamic Control (미세채널에서 수력학적 조절을 통한 단분산성 다중 액적 생성)

  • Kang, Sung-Min;Choi, Chang-Hyung;Hwang, Sora;Jung, Jae-Min;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.733-737
    • /
    • 2012
  • This study reports the microfluidic preparation of monodisperse multiple emulsions using hydrodynamic control. To generate multiple emulsions, we fabricate a microfluidic capillary device based on co-flowing stream without any surface modification of microchannels. Based on the system, we can successfully generate multiple emulsions (W/O/W) using water containing 0.5 wt% Tween 20, n-hexadecane with 5 wt% Span 80, and 10 wt% poly (vinyl alcohol) (PVA) aqueous solution, respectively. Furthermore, we control the number of inner droplets by modulation of flow rate of inner fluid at fixed flow rate of middle and outer fluid. The multiple emulsions having precisely controlled inner droplets' size and number can be applicable for multiple chemical reactions as an isolated microreactor.

An Experimental Study on Pressure Drop and Heat Transfer Coefficient of Laminar Ag Nanofluid Flow in Mini-Tubes (은 나노유체의 미세관내 층류 유동의 압력강하 및 열전달계수에 관한 실험적 연구)

  • Kwon, Jeong-Tae;Nahm, Taek-Hun;Kim, Tae-Wan;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3525-3532
    • /
    • 2009
  • This study presents the heat transfer and pressure drop characteristics of Ag nanofluid in mini-tubes(outer diameters of 1/8inch, 3/16inch). Experiments were performed for Reynolds numbers ranged from 500 to 2,500 and nanofluid concentrations of 0.1 and 0.3vol.%. The pressure drop of nanofluid flow increased by max. 21% compared with that of distilled water. The heat transfer coefficients of the nanofluid of 0.1 vol.% enhanced 3~42% for 1/8inch tube, and 3~69% for 3/16inch tube. Also, the heat transfer coefficients of the nanofluid of 0.3 vol.% enhanced 35~65% for 1/8inch tube, and 62~125% for 3/16inch tube. From the results Ag nanofluid can be a better candidate as a coolant than distilled water when using in mechanical and/or electronic systems.

Rheological Study on the die Swell of a Suspension (현탁액의 Die Swell 현상에 대한 유변학적 연구)

  • 김동표
    • The Korean Journal of Rheology
    • /
    • v.3 no.2
    • /
    • pp.117-123
    • /
    • 1991
  • 현탁액에 대한 기본적인 유변학적 특성을 조사하기 위해 입자의 부피분율에 따른 점도의 변화를 측정하였고 현탁액의 Die Swell 현상에 대해 실험적으로 규명하였다. 뉴톤성 특성을 조사하기 위해 입자의 부피 분율에 따른 점도의 변화를 측정하였고 현탁액의 Die Swell 현상에 대해 실험적으로 규명하였다. 뉴톤성 특성을 갖는 Silicone 오일을 현탁 매질 로 사용하였고 미세한 유리 구슬이 filler로써 사용되었다. 현탁액의 점도는 Couette 점도계 와 모세관 점도계를 사용하였다. 관의 입구와 출구에 대한 보정을 위해서 Bagley의 방법을 이용하였으며 중력으로 인한 Swell의 감소효과를 제거하기 위해서 분사 유체와 유사한 밀 도를 지니며 분사 유체와 섞이지 않는 유체를 담은 부력용기가 사용되었다. Die Swell 현상 은 사진을 찍고 이를 정밀한 확대경을 통해 관찰함으로써 수치적으로 값을 얻었다.

  • PDF

Numerical Study on Flow and Heat Transfer Enhancement during Flow Boiling in Parallel Microchannels (병렬 미세관 흐름비등의 유동특성 및 열전달 향상에 대한 수치적 연구)

  • Jeon, Jin-Ho;Lee, Woo-Rim;Suh, Young-Ho;Son, Gi-Hun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.472-473
    • /
    • 2008
  • Flow boiling in parallel microchannels has received attention as an effective heat sink mechanism for power-densities encountered in microelectronic equipment. the bubble dynamics coupled with boiling heat transfer in microchannels is still not well understood due to the technological difficulties in obtaining detailed measurements of microscale two-phase flows. In this study, complete numerical simulation is performed to further clarify the dynamics of flow boiling in microchannels. The level set method for tracking the liquid-vapor interface is modified to include the effects of phase change and contact angle. The method is further extended to treat the no-slip and contact angle conditions on the immersed solid. Also, the reverse flow observed during flow boiling in parallel microchannels has been investigated. Based on the numerical results, the effects of channel shape and inlet area restriction on the bubble growth, reverse flow and heat transfer are quantified.

  • PDF

Development of Mobile Robot Systems for Automatic Diagnosis of Boiler Tubes in Fossil Power Plants and Large Size Pipelines (화력발전소 보일러 튜브 및 대형 유체수송관 자동 진단을 위한 이동로봇 시스템 개발)

  • Park, Sang-Deok;Jeong, Hee-Don;Lim, Zhong-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.3
    • /
    • pp.254-260
    • /
    • 2002
  • In this study, two types of mobile robotic systems using NDT (Non-destructive testing) method are developed for automatic diagnosis of the boiler tubes and large size pipelines. The developed mobile robots crawl the outer surface of the tubes or pipelines and detect in-pipe defects such as pinholes, cracks and thickness reduction by corrosion and/or erosion using EMAT (Electro-magnetic Acoustic Transducer). Automation of fault detection by means of mobile robotic systems for these large-scale structures helps to prevent significant troubles without danger of human beings under harmful environment.

fs-laser Ablation and Optoperforation Threshold for PDMS Thin Film on $\mu$-channel (미세 유체 상 PDMS 고분자 필름의 펨토초 레이저 어블레이션 및 천공 임계치 연구)

  • Woo, Suk-Yi;Sidhu, M.S.;Yoon, Tae-Oh;Jeoung, Sae-Chae;Park, Il-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.29-33
    • /
    • 2010
  • We have investigated fs-laser ablation as well as optoperforation threshold of PDMS (Polydimethylsiloxane) thin lid cover on ${\mu}$-channel with changing the flow medium from water to hemoglobin. The ablation threshold is found to be independent of both PDMS thin film thickness and flow medium, but the optoperforation threshold is dependent on the films thickness. The observation that the ablation process is well described with simple two-temperature model supposed that the cover lid PDMS of $\mu$-channel be processed with minimized thermal effects by fs-laser with low laser fluence.

Analysis of Heat Transfer Performance for Mini-Channel Tube Bundles in Cross flow using CFD (전산유체역학을 이용한 직교류 미세관 관군의 전열 성능 해석)

  • Nam, Ki-Won;Min, Jun-Kee;Jeong, Ji-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.491-499
    • /
    • 2010
  • Heat transfer performance of tube bundles have long been investigated since they were widely used. Most of previous experimental and numerical works for tube bundles were performed with tube diameter in the range of 25~51mm and Reynolds number of $8.000{\leq}Re{\leq}30.000$. Recently, tube bundles with small diameter tube collects interests since the mini-channel tube provides higher compactness. The present work aims to investigate the applicability of previous correlations available in the open literature to the tube bundles with small diameter of 1.5mm and $3.000{\leq}Re{\leq}7.000$. A commercial CFD package was used to analyze the thermal-hydraulic performance of them. The results show that the Zukauskas correlation developed for larger diameter tube and higher Reynolds number are still in good agreement with them within the discrepancy of 4.7%. The analyses also show that the Nuselt number increases with a decrease in the longitudinal pitch.

Analysis of Capillary Flow in Open-Top Rectangular Microchannel (상판이 없는 직사각형 단면의 미세채널에서 모세관 유동 분석)

  • Park, Eun-Jung;Cho, Ji-Yong;Kim, Jeong-Chul;Hur, Dae-Sung;Chung, Chan-Il;Kim, Jung-Kyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.77-82
    • /
    • 2010
  • Our study aims to understand the flow of liquid in an open-top rectangular microchannel that can be used in micro total analysis systems ($\mu$-TAS) because it has advantages in terms of light transmission and energy efficiency. We measured the liquid velocity using particle tracking technique and conducted a simulation with computational fluid dynamics by altering the area of channel cross section and channel length for the capillary-driven flow in the open-top rectangular microchannel. When liquid water drops to an entrance of the fabricated microchannel with a height of 20 μm and a width of 20 ${\mu}m$, it flows along the microchannel by only capillary force. In the wetting behavior of the liquid, important parameters of this flow are channel size, contact angle and liquid properties such as surface tension and viscosity, which are used to control the flow of liquid in the microchannel.

Chip-based microcapillary HPLC for proteomic analysis (칩 기반 미세관 HPLC를 이용한 단백체 분석)

  • Kim, Bo-Ra;Park, Jong-Moon;Lee, Hoo-Keun
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.407-413
    • /
    • 2011
  • Over the last decade sophisticated and powerful microcapillary HPLC for proteomic analysis have been developed increasingly and interfaced with high resolution tandem mass spectrometers. Separation prior to mass spectrometric (MS) analysis removes impurities, and concentrates analytes in the narrow elution peaks, resulting in increased sensitivity of MS analysis. This review will focus on the recent advances of on-line highperformance separation techniques based on microfluidic chips for complex proteomic analysis.