• 제목/요약/키워드: 미세 누출

검색결과 243건 처리시간 0.017초

접착제 도포후 오염된 표면의 처리방법에 따른 복합레진의 전단결합강도와 미세누출 (SHEAR BOND STRENGTH AND MICROLEAKAGE OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF CONTAMINATED SURFACE AFTER APPLYING A BONDING AGENT)

  • 박주식;이석종;문주훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.647-656
    • /
    • 1999
  • The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.

  • PDF

수산화칼슘-유지놀 화합물의 물성 (PROPERTIES OF CALCIUM HYDROXIDE-EUGENOL COMPOUND)

  • 박준철;권태경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.408-415
    • /
    • 1999
  • 수산화칼슘은 높은 항균성으로 인해 최근에 근관소독제로 사용이 추천되고 있는 약제이다. 본 연구자는 근관내에 수산화칼슘을 투약한 후에 산화아연유지놀계 시멘트로 근관 충전을 하는 경우 근관시멘트의 물성의 변화를 경험할 수 있었다. 본 연구의 목적은 수산화칼슘을 근관내에 투약 후 근관충전재로 산화아연유지놀계 시멘트를 사용하는 경우 발생하는 근관시멘트의 물성변화를 알아보기 위함이다. 이를 위하여 수산화칼슘-유지놀 화합물의 불성 중 용해도, 흡수성, 피막도 및 변연폐쇄성을 기성 산화아연유지놀계 근관 시멘트인 Tubli-seal$^{(R)}$과 비교하여 연구하였다. 용해도와 흡수생의 측정을 위하여 ADAS No. 57에 따라 지름 20mm 두께 15mm인 시편을 제작하여 $37^{\circ}C$ 50ml의 증류수에 7일간 침잠후 무게의 변화를 측정하였고, 피막도 측정을 위하여 ADAS No. 57에 따라 두 유리판 사이에 실험물질을 위치시키고 15 Kg의 하중을 가한 후에 두께의 증가를 측정하였다. 마지막으로 변연폐쇄성 측정을 위해서는 우치 상아질 면과 아크릴 봉 사이에 실험물질을 위치시킨 후 3일 동안 Pelican ink에 침잠시킨 후 색소의 침투 면적을 계산하여 다음과 같은 결과를 얻었다. ${\cdot}$ 수산화칼슘-유지놀 화합물의 흡수성은 59.72${\pm}$17.75%로 측정되어 3.15${\pm}$0.76%로 측정된 Tubli-seal$^{(R)}$에 비해 유의하게 높게 나타났다(p<0.05). ${\cdot}$ 수산화칼슘-유지놀 화합물의 용해도가 20.98${\pm}$2.94%로 측정되어 2.52${\pm}$0.49%로 측정된 Tubli-seal$^{(R)}$에 비해 유의하게 높게 나타났다(p<0.05). ${\cdot}$ 수산화칼슘-유지놀 화합물의 피막도가 0.36${\pm}$0.03 mm로 측정되어 0.12${\pm}$0.01mm로 측정된 Tubli-seal$^{(R)}$에 비해 유의하게 높게 나타났다(p<0.05). ${\cdot}$ 수산화칼슘-유지놀 화합물의 미세누출은 3일 동안의 색소 침투면적이 57.63${\pm}$25.85%로 측정되어 28.05${\pm}$23.46%로 측정 된 Tubli-seal$^{(R)}$에 비해 유의하게 높게 나타났다(p<0.05).

  • PDF

기압과 기온변화가 자발성 기흉 발생에 미치는 영향 (Influence of Change of Atmospheric Pressure and Temperature on the Occurrence of Spontaneous Pneumothorax)

  • 이건;임창영;이헌재
    • Journal of Chest Surgery
    • /
    • 제40권2호
    • /
    • pp.122-127
    • /
    • 2007
  • 배경: 자발성 기흉은 임상에서 흔히 접하는 호흡계 질환으로, 기낭의 파열로 인해 누출된 공기가 흉강에 축적되는 질환이다. 기흉의 원인이 되는 기낭의 형태와 미세구조는 잘 알려져 있으나 기낭이 파열되는 원인에 대해서는 명확히 밝혀지지 않았다. 그 동안 기상요소인 기압 및 기온이 자발성 기흉의 발생에 미치는 영향을 밝히기 위해 많은 연구가 이루어졌으나 아직까지 명확히 밝혀진 바는 없다. 본 연구는 기압과 기온의 변화가 자발성 기흉의 발생에 미치는 영향을 알아보기 위해 실시하였다. 대상 및 방법: 2003년 1월부터 2004년 12월까지 본원에 입원하여 치료를 받은 환자 109명에서 발생한 자발성 기흉 128예를 연구대상으로 했다. 연구기간을 기흉이 발생한 날들과 발생하지 않은 날들로 분류하여, 기상청 자료 중 각각의 날에 해당하는 기압요소(평균기압, 최고기압, 최저기압, 기압일교차)와 기온요소(평균기온, 최고기온, 최저기온, 기온일교차)를 구하였다. 기흉이 발생한 날로부터 발생 전 5일까지, 기흉이 발생하지 않은 날도 그 전 5일까지 하루씩 전날로부터의 기압과 기온의 변화폭을 구하여, 독립변수인 기압과 기온변화가 종속변수인 기흉 발생여부에 미치는 영향을 분석하였다. 결과: 연구기간의 16.0%에 해당하는 117일 동안 자발성 기흉이 발생하였다. 기흉이 발생한 당일 및 그 전4일까지는 기압요소의 변화폭이 기흉이 발생하지 않은 날 및 그 전 4일까지와 특별한 차이가 없었으나, 기흉 발생 4일 전은, 기흉이 발생하지 않은 날 4일 전보다 전날 대비 평균기압이 높고(+0.934 vs. -0.191 hPa, RR 1.042, Cl $1.003{\sim}1.082$, p=0.033), 기압하강폭(전일 최고기압-당일 최저기압)은 적었다. (3.280 vs. 4.791 hPa, RR 1.051, Cl $1.013{\sim}l.090$, p=0.009). 기온요소는 기흉 발생 2일전이, 기흉이 발생하지 않은 날 2일 전보다 전날 대비 평균기온이 낮고(-0.576 vs.+$0.099^{\circ}C$, RR 0.886, 95% Cl $0.817{\sim}0.962$, p=0.004) 기온상승폭(당일 최고기온-전일 최저기온)도 적었다(7.231 vs. $8.079^{\circ}C$, RR 0.943, Cl $0.896{\sim}0.993$, p=0.027). 그러나 기흉 발생 당일은 기흉이 발생하지 않은 날 당일보다 전일 대비 평균 기온이 높고(0.533 vs. $-0.103^{\circ}C$, RR 1.141, Cl $1.038{\sim}l.255$, p=0.006), 기온상승폭도 컸다(9.209 vs. $7.754^{\circ}C$, RR 1.123, Cl $1.061{\sim}1.190$, p=0.000). 결론: 본 연구의 결과를 통해 저자들은 기압이 상승한 뒤 기온이 상승했다. 하강하는 약 4일간의 기상변화가 자발성 기흉 발생에 영향을 미친다고 추론할 수 있었다. 향후 본 연구에서 추론된 기상변화와 기흉 발생과의 인과관계를 확인하고 좀 더 구체화하기 위한 연구가 필요할 것이다.