• Title/Summary/Keyword: 미세결합

Search Result 714, Processing Time 0.026 seconds

LIGA-reflow Micro-lens Pattern 적용 도광판의 미세사출성형

  • 황철진;허영무;하수용;이규현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.134-134
    • /
    • 2004
  • LCD-BLU의 고효율 광특성을 유도하기 위한 도광판의 초미세패턴 형상가공기술, 미세사출성형기술과 미세형상패턴 광학해석기술 및 전광특성 측정 및 보완기술이 요구된다. 이러한 기술들을 바탕으로 LCD-BLU의 고단가의 주요요인인 기능성 광학 sheet(prism sheet 등)를 연차적으로 제거 및 도광판에 기능을 결합하는 기술개발이 본 연구의 목적이다.(중략)

  • PDF

Effects of Electron-beam. Patterns on Microstructures of Silicon for Photovoltaic Applications (전자빔패턴에 따른 태양전지용 실리콘의 미세구조)

  • Choi, Sun-Ho;Jang, Bo-Yun;Kim, Joon-Soo;Ahn, Young-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.224-224
    • /
    • 2010
  • 야금학적 정련은 태양전지 소재인 실리콘의 저가화를 통한 태양전지의 단가를 낮추는데 유망한 공정이다. 이중에서도 실리콘의 전자빔정련은 고순도의 실리콘 정련에 효과적인 기술이다. 본 연구에서는 전자빔용융법을 이용하여 실리콘 정련을 수행하였으며, 제조된 실리콘의 미세구조 및 분순물농도를 측정하였다. 고진공의 챔버 하부에 수냉동도가니가 위치해있고, 상부에 100 kW출력의 전자총이 설치되었다. 실리콘은 분쇄 및 세척과 같은 전처리 없이 수냉동도가니에 250g 이 장입되었다. 전자빔때턴은 소프트웨어를 통한 헌혈, 나선형의 경로(path)와 원형의 형상(Shape)이 결합하여 원형패턴과 나선형패턴의 형상으로 실리콘에 조사되었다. 전자빔의 출력을 15 kW로 실리콘을 용융하였고 분당 0.5 kW의 속도로 서냉하였다. 제조된 실리콘은 지름 100 mm, 높이 25 mm의 버튼형상이었으며, 횡방향으로 절단하여 미세구조와 불순물거동을 분석하였다. 미세구조는 광학현미경 (OM) 과 전자현미경 (SEM)을 통하여 관찰하였고 불순물거동은 유도결합플라즈마 분광분석기(ICP-AES) 을 통하여 분석하였다. 장입된 실리콘의 초기순도는 99.5 %이고, 전자빔정련 공정 후 99.996 %까지 향상되었다. 전자빔패턴을 이용한 고순도 실리콘의 정련은 태양전지 소재 개발에 유망한 기술로 활용될 것이다.

  • PDF

EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS (Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향)

  • Oh, Eun-Hwa;Choi, Kyoung-Kyu;Kim, Jong-Ryul;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.148-161
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of chlorhexidine (CHX) on microtensile bond strength (${\mu}TBS$) of dentin bonding systems. Dentin collagenolytic and gelatinolytic activities can be suppressed by protease inhibitors, indicating that MMPs (Matrix metalloproteinases) inhibition could be beneficial in the preservation of hybrid layers. Chlorhexidine (CHX) is known as an inhibitor of MMPs activity in vitro. The experiment was proceeded as follows: At first, flat occlusal surfaces were prepared on mid-coronal dentin of extracted third molars. GI (Glass Ionomer) group was treated with dentin conditioner, and then, applied with 2 % CHX. Both SM (Scotchbond Multipurpose) and SB (Single Bond) group were applied with CHX after acid-etched with 37% phosphoric acid. TS (Clearfil Tri-S) group was applied with CHX, and then, with adhesives. Hybrid composite Z-250 and resin-modified glass ionomer Fuji-II LC was built up on experimental dentin surfaces. Half of them were subjected to 10,000 thermocycle, while the others were tested immediately. With the resulting data, statistically two-way ANOVA was performed to assess the ${\mu}TBS$ before and after thermo cycling and the effect of CHX. All statistical tests were carried out at the 95 % level of confidence. The failure mode of the testing samples was observed under a scanning electron microscopy (SEM). Within limited results, the results of this study were as follows; 1. In all experimental groups applied with 2 % chlorhexidine, the microtensile bond strength increased, and thermo cycling decreased the micro tensile bond strength (P > 0.05). 2. Compared to the thermocycling groups without chlorhexidine, those with both thermocycling and chlorhexidine showed higher microtensile bond strength, and there was significant difference especially in GI and TS groups. 3. SEM analysis of failure mode distribution revealed the adhesive failure at hybrid layer in most of the specimen. and the shift of the failure site from bottom to top of the hybrid layer with chlorhexidine groups. 2 % chlorhexidine application after acid-etching proved to preserve the durability of the hybrid layer and microtensile bond strength of dentin bonding systems.

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

ENAMEL ADHESION OF LIGHT-AND CHEMICAL-CURED COMPOSITES COUPLED BY TWO STEP SELF-ETCH ADHESIVES (2단계 자가 산부식 접착제와 결합된 광중합과 화학중합 복합레진의 법랑질 접착)

  • Han, Sae-Hee;Kim, Eun-Soung;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.169-179
    • /
    • 2007
  • This study was to compare the microshear bond strength $({\mu}SBS)$ of light- and chemically cured composites to enamel coupled with four 2-step self-etch adhesives and also to evaluate the incompatibility between 2-step self-etch adhesives and chemically cured composite resin. Crown segments of extracted human molars were cut mesiodistally, and a 1 mm thickness of specimen was made. They were assigned to four groups by adhesives used: SE group (Clearfil SE Bond) AdheSE group (AdheSE), Tyrian group (Tyrian SPE/One-Step Plus), and Contax group (Contax) Each adhesive was applied to a cut enamel surface as per the manufacturer's instruction. Light-cured (Filtek Z250) or chemically cured composite (Luxacore Smartmix Dual) was bonded to the enamel of each specimen using a Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n=20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at 95% level. Also the interface of enamel and composite was evaluated under FE-SEM. The results of this study were as follows ; 1. The ${\mu}SBS$ of the SE Bond group to the enamel was significantly higher than that of the AdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin (p < 0.05). 2. There was not a significant difference among the hdheSE group, the Tyrian group, and the Contax group in both the light-cured and the chemically cured composite resin. 3. The ${\mu}SBS$ of the light-cured composite resin was significantly higher than that of the chemically cured composite resin when same adhesive was applied to the enamel (p < 0.05). 4. The interface of enamel and all 2-step self-etch adhesives showed close adaptation, and so the incompatibility of the chemically cured composite resin did not show.

Direct Interaction of KIF5s and Actin-Based Transport Motor, Myo9s (KIF5s와 직접 결합하는 액틴 결합 운동단백질 Myo9s의 규명)

  • Seog, Dae-Hyun
    • Journal of Life Science
    • /
    • v.21 no.8
    • /
    • pp.1076-1082
    • /
    • 2011
  • Microtubule-based kinesin motor proteins are used for long-range vesicular transport. KIF5s (KIF5A, KIF5B and KIF5C) mediate the transport of various membranous vesicles along microtubules, but the mechanism behind how they recognize and bind to a specific cargo has not yet been completely elucidated. To identify the interaction protein for KIF5B, yeast two-hybrid screening was performed and a specific interaction with the unconventional myosin Myo9b, an actin-based vesicle transport motor, was found. The GTPase-activating protein (GAP) domain of Myo9s was essential for interaction with KIF5B in the yeast two-hybrid assay. Myo9b bound to the carboxyl-terminal region of KIF5B and to other KIF5 members. In addition, glutathione S-transferase (GST) pull-downs showed that Myo9s specifically interact to the complete Kinesin-I complex. An antibody to KIF5B specifically co-immunoprecipitated KIF5B associated with Myo9s from mouse brain extracts. These results suggest that kinesin-I motor protein interacts directly with actin-based motor proteins in the cell.

Effect of Surface Treatments of on the Microtensile Bond Strength of Resin Composite to Composite after aging Conditions (시효처리 후의 컴포지트에 대한 레진 컴포지트의 미세 인장 결합강도에 표면처리가 미치는 효과)

  • Yoo, Min-Jin;Her, Mi-Ja;Kim, Hee-Lyang;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.339-347
    • /
    • 2010
  • Enhancement of bond strength between new and old composite usually requires increasing the surface roughness to promote mechanical interlocking. This study evaluated the effect of different surface treatments on repair bond strength of resin composite after aging condition. Air abrasion with Al2O3, chairside silicacoating, and silanization provided higher resin-resin bond strength values compared to control group and HF group. Air abrasion is necessary to repair a resin restoration and additional application of silane seems to have good effects on bond strength.

Spatio-Temporal 3D Joint Noise Reduction Filter (시공간 3차원 결합 잡음제거 필터)

  • 홍성훈;홍성용
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.2
    • /
    • pp.147-157
    • /
    • 2002
  • Noise in image sequences is visually offensive and may mask important image detail. In addition to degradation of visual quality, the noise pattern increases the entropy of the image, and thus hinders effective compression. This paper proposes a spatial and a temporal joint filters to reduce the noise by jointly connecting two adaptive noise reducers with different characteristics, and we also propose an IIR-type 3D noise reduction litter scheme connecting the spatial and the temporal joint filters. The proposed 3D IIR filter not only strongly removes noise in uniform image regions while preserving edges and details but also effectively suppresses temporal flicker caused by noise. Experimental results show that the proposed scheme improves subjective quality as well as objective quality as compared with the various noise filtering techniques.

  • PDF

Growth Mechanisms of Graphite Spherulites in the Nodular Cast Iron and the High-pressure-treated Ni-C alloy (구상흑연 주철과 고압처리된 Ni-C 합금에서 구상화 흑연의 성장 기구)

  • Park, Jong-Ku;Ahn, Jae-Pyoung;Kim, Gyeungho;Kim, Soo-Chul
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.200-207
    • /
    • 2000
  • The growth mechanisms of graphite spherulite both in the nodular cast iron and the high pressuretreated Ni-C alloy were investigated by SEM, HRTEM and EELS. The internal microstructure and lattice image of graphite spherulite extracted from Ni-C alloy were compared with those of graphite spherulite extracted from the nodular cast iron. The ratios of $sp^2$ and $sp^3$ bonding in the respective graphite spherulite measured by EELS, are compared each other. The graphite spherulite of Ni-C alloy had little internal defects and much $sp^3$ carbon species compared to that of the nodular cast iron. Present difference in microstructural features and bonding characters indicated that the graphite spheruites in the high pressuretreated Ni-C alloy grew by different mechanism compared with those in the nodular cast iron.

  • PDF

THE EFFECT OF DIFFERENT CURING MODES ON COMPOSITE RESIN/DENTIN BOND STRENGTH IN CLASS ICAVITIES (1급 와동에서 상아질과 복합레진의 결합강도에 대한 중합방법의 효과)

  • Baek, Shin-Young;Cho, Young-Gon;Song, Byeong-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.428-434
    • /
    • 2008
  • The purpose of this study was to compare the microtensile bond strength in Class I cavities associated with different light curing modes of same light energy density. Occlusal enamel was removed to expose a flat dentin surface and twenty box-shaped Class I cavities were prepared in dentin. Single Bond (3M Dental product) was applied and Z 250 was inserted using bulk technique. The composite was light-cured using one of four techniques, pulse delay (PD group), soft-start (SS group), pulse cure (PC group) and standard continuous cure (CC group). The light-curing unit capable of adjusting time and intensity (VIP, Bisco Dental product) was selected and the light energy density for all curing modes was fixed at $16J/cm^2$. After storage for 24 hours, specimens were sectioned into beams with a rectangular cross-sectional area of approximately $1mm^2$ Microtensile bond strength $({\mu}TBS)$ test was per- formed using a univel·sal testing machine (EZ Test, Shimadzu Co.). The results were analyzed using oneway ANOVA and Tukey's test at significance level 0.05. The ${\mu}TBS$ of PD group and SS group was higher than that of PC group and CC group. Within the limitations of this in vitro study, modification of curing modes such as pulse delay and soft start polymerization can improve resin/dentin bond strength in Class I cavities by controlling polymerization velocity of composite resin.