• Title/Summary/Keyword: 미사일 시뮬레이션

Search Result 72, Processing Time 0.017 seconds

Improvement of Computational Complexity of Device-to-Device (D2D) Resource Allocation Algorithm in LTE-Advanced Networks (LTE-Advanced 환경에서 D2D 자원 할당 알고리즘의 계산 복잡도 개선)

  • Lee, Han Na;Kim, Hyang-Mi;Kim, SangKyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.4
    • /
    • pp.762-768
    • /
    • 2015
  • D2D communication as an underlaying LTE-Advanced network has proven to be efficient in improving the network performance and decreasing the traffic load of eNodeB(enhanced NodeB). However large amount of interference can be caused by sharing the resources between the cellular users and D2D pairs. So, a resource allocation for D2D communication to coordinate the interference is necessary. Related works for resource allocation that D2D can reuse the resources of more than one cellular user with best CQI(Channel Quality Indicator) have been proposed. D2D communications may still cause interference to the primary cellular network when radio resource are shared between them. To avoid this problem, we propose a radio resource allocation algorithm with low computational complexity for D2D communication in OFDM-based wireless cellular networks. Unlike the previous works, the proposed algorithm utilizes unused ones of the whole resource. The unused resource allocate to on D2D pair can be shared only with other D2D pairs. In other words, if the distance between the D2D pairs is sufficient, we allowed more than two D2D pairs to share the same resources. The simulation results have proven that the proposed algorithm has up to 11 times lower computational complexity than the compared one according to the number of D2D.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.