• Title/Summary/Keyword: 미끄럼

Search Result 666, Processing Time 0.023 seconds

A Study on the Self-Propulsion CFD Analysis for a Catamaran with Asymmetrical Inside and Outside Hull Form (안팎 형상이 비대칭인 쌍동선의 자항성능 CFD 해석에 관한 연구)

  • Jonghyeon Lee;Dong-Woo Park
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.1
    • /
    • pp.108-117
    • /
    • 2024
  • In this study, simulations based on computational fluid dynamics were performed for self-propulsion performance prediction of a catamaran that has asymmetrical inside and outside hull form and numerous knuckle lines. In the simulations, the Moving Reference Frame (MRF) or Sliding Mesh (SDM) techniques were used, and the rotation angle of the propeller per time step was different to identify the difference using the analysis technique and condition. The propeller rotation angle used in the MRF technique was 1˚ and those used in the SDM technique were 1˚, 5˚, or 10˚. The torque of the propeller was similar in both the techniques; however, the thrust and resistance of the hull were computed lower when the SDM technique was applied than when the MRF technique was applied, and higher as the rotation angle of the propeller per time step in the SDM technique was smaller in the simulations for several revolutions of the propeller to estimate the self-propulsion condition. The revolutions, thrust, and torque of the propeller in the self-propulsion condition obtained using linear interpolation and the delivered power, wake fraction, thrust deduction factor, and revolutions of the propeller obtained using the full-scale prediction method showed the same trend for both the techniques; however, most of the self-propulsion efficiency showed the opposite trend for these techniques. The accuracy of the propeller wake was low in the simulations when the MRF technique was applied, and slight difference existed in the expression of the wake according to the rotation angle of the propeller per time step when the SDM technique was applied.

Properties of Temperature Reduction of Cooling Asphalt Pavements Using High-Reflectivity Paints (고반사 도료를 사용한 차열성 아스팔트 도로포장의 온도저감특성)

  • Hong, Chang Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.317-327
    • /
    • 2013
  • Air pollution and artificial heat of urban areas have caused the urban heat island in which asphalt pavements absorb solar heat during the daytime and release the heat at night. Hence, in order to improve the environment of urban areas, it is necessary to examine cooling pavements that can reduce heat on road pavements in urban areas. The application of temperature insulation paints on road pavements require to reduce black brightness for visibility, to increase the reflection rate of infrared light and minimize the reflection rate of visible light. In the study, one part of Acrylic-emulsion was used as a main binder, and the changes in black brightness and the changes of addition ratio (0%, 15%, 30%) of hollow ceramics, as well as kinds of paints (carbon black pigment, mixed mineral pigment) were selected as the main experimental factors. The performance of temperature reduction of cooling pavements was analyzed through the reflection rate of spectrum, the reflection rate of solar heat, and the lamp test. Abrasion resistance, UV accelerated weather resistance, and sliding resistance were tested in real situations. In addition, the performance of heat reduction of testing pavements covered with high-reflection paints was analyzed by using an infrared camera. As the test results, when using mixed mineral paints and hollow ceramic of 30%, the reflection rate of spectrum was 43% in the area of near-infrared ray and 17% in the area of visible light at black brightness of $L^*$=42.89 and the reflection rate of solar heat was 27.5%. Total color difference was ${\Delta}E$=0.27 in the test of UV Accelerated Weather Resistance, indicating almost no changes in color. BPN was more than 53 when scattering #2 and #4 silica sand of more than $0.12kg/m^2$. In Taber's abrasion resistance test, abrasion loss was up to 86.4mg at 500 rotations. The performance of heat reduction was evaluated using an infrared camera at the test section applying high-reflection paints to asphalt pavements, in which the results showed that the temperature was reduced by $12.7^{\circ}C$ on CI-30-40 cooling pavements ($L^*$=38.76) and by $14.2^{\circ}C$ on CI-30-60 cooling pavements ($L^*$=57.12).

Teachers' Importance Perception on Elderly Housing Contents in the Housing Chapter of Middle School Technology and Home Economics Textbook (주생활단원의 노인주거 내용에 대한 교사의 중요도 인식 - 중학교 3학년 기술 가정 교과서를 중심으로 -)

  • June, Kyung-Sook
    • Journal of Korean Home Economics Education Association
    • /
    • v.21 no.3
    • /
    • pp.1-28
    • /
    • 2009
  • The purpose of this research was to provide the information needed for improving the elderly housing education and the elderly housing contents of Technology and Home Economics textbook. Thus, the elderly housing contents of current Technology and Home Economics textbook were categorized. Then, a total of 233 teachers were surveyed to examine their importance perception on the elderly housing contents. Elderly housing contents were grouped into S categories, each of which was named 'safety and safety management', 'room plan for the elderly', 'shrinking stage in family life cycle and dependency stage in housing life cycle','a house for 3-generation extended family', and 'universal design'. Teachers' importance perception was generally high for 'safety and safety management' and especially for 'safety and safety management' of bathroom(protection against slippery floor, safety bar, the appropriate position and height of shower, bathtub, and wash stand) ; the basic guidelines of 'room plan for the elderly'(emergency call, closely located bathroom, flat and non-slippery floor) ; the general guidelines during shrinking stage in family life cycle and dependency stage in housing life cycle'(protection equipments against safety accident, emergency call, flat and non-slippery floor) ; independent life among 3-generation extended family members(bathroom for the elderly, space plan for independent life among extended family members) ; the basic design guidelines of universal design(safety bar in bathroom, flat floor) and the guidelines of universal design which were especially helpful for wheelchair users(enough empty space in front of door and in corridor, wide door and corridor). Recommendations for the elderly housing education and the elderly housing contents of Technology and Home Economics textbook were that 'emergency call','safety bar in bathroom' and 'flat and non-slippery floor' were the most basic guidelines for elderly housing; that 'enough empty space in front of door and in corridor', 'wide door and corridor', 'low and wide steps', 'ramp for wheelchair users' and 'D-type or lever-type door handle' were most recommendable guidelines for universal design; that 'need for elderly housing', 'types of elderly housing', 'alternatives and choices of dependency stage in housing life cycle' and 'house plans for shrinking stage in family life cycle' were required guidelines for increasing elderly-only family.

  • PDF

Acoustic Characteristics of Gas-related Structures in the Upper Sedimentary Layer of the Ulleung Basin, East Sea (동해 울릉분지 퇴적층 상부에 존재하는 가스관련 퇴적구조의 음향 특성연구)

  • Park, Hyun-Tak;Yoo, Dong-Geun;Han, Hyuk-Soo;Lee, Jeong-Min;Park, Soo-Chul
    • Economic and Environmental Geology
    • /
    • v.45 no.5
    • /
    • pp.513-523
    • /
    • 2012
  • The upper sedimentary layer of the Ulleung Basin in the East Sea shows stacked mass-flow deposits such as slide/slump deposits in the upper slope, debris-flow deposits in the middle and lower slope, and turbidites in the basin plain. Shallow gases or gas hydrates are also reported in many area of the Ulleung Basin, which are very important in terms of marine resources, environmental changes, and geohazard. This paper aims at studying acoustic characteristics and distribution pattern of gas-related structures such as acoustic column, enhanced reflector, dome structure, pockmark, and gas seepage in the upper sedimentary layer, by analysing high-resolution chirp profiles. Acoustic column shows a transparent pillar shape in the sedimentary layer and mainly occurs in the basin plain. Enhanced reflector is characterized by an increased amplitude and laterally extended to several tens up kilometers. Dome structure is characterized by an upward convex feature at the seabed, and mainly occurs in the lower slope. The pockmark shows a small crater-like feature and usually occurs in the middle and lower slope. Gas seepage is commonly found in the middle slope of the southern Ulleung Basin. These gas-related structures seem to be mainly caused by gas migration and escape in the sedimentary layer. The distribution pattern of the gas-related structures indicates that formation of these structures in the Ulleung Basin is controlled not only by sedimentary facies in upper sedimentary layer but also by gas-solubility changes depending on water depth. Especially, it is interpreted that the chaotic and discontinuous sedimentary structures of debris-flow deposits cause the facilitation of gas migration, whereas the continuous sedimentary layers of turbidites restrict the vertical migration of gases.

Comparative analysis of status of safety accidents and importance-performance analysis (IPA) about precautions of safety accidents by employment type of industry foodservices in Jeonbuk area (전북지역 산업체급식소 조리종사자의 고용형태에 따른 안전사고 실태 및 안전사고 예방관리에 대한 중요도와 수행도 분석)

  • So, Hee;Rho, Jeong Ok
    • Journal of Nutrition and Health
    • /
    • v.50 no.4
    • /
    • pp.402-414
    • /
    • 2017
  • Purpose: The purpose of the study was to evaluate the status of safety accidents and importance-performance analysis (IPA) between regular and non-regular employees in industry foodservices. Methods: The participants were regular employees (n = 119) and non-regular employees (n = 163) in industry foodservices in the Jeonbuk area. Demographic characteristics, status of safety accidents, safety education, and importance and performance status were assessed using a self-administered questionnaire. Results: Approximately 66.4% of regular employees and 53.4% of non-regular employees experienced safety accidents (p < 0.05). Types of safety accidents of regular and non-regular employees were mostly burns, and causes were mostly from their own negligence. Approximately 98.3% of regular employees and 95.1% of non-regular employees experienced safety education. Approximately 88.9% of regular employees and 96.8% of non-regular employees received safety education from dietitians. Approximately 41.9% of regular employees and 50.0% of non-regular employees had difficulty applying the contents of safety education due to lack of time during work. As a result of IPA, regular and non-regular employees were aware of the importance of the following and performed them well: 'Clean the floor of the work place', 'Arrange in the work area', 'Wear safety shoes', 'Check for heater cord', and 'Safety cooking when using oil'. On the other hand, they were not aware of the importance of the following and performed them insufficiently: 'Check for the MSDS', 'Aware of chemical signs', 'Wear protection gloves etc.', 'Do stretching exercise', and 'Using ancillary tools'. Conclusion: Therefore, it is necessary to improve the consciousness of dietitians for effective application of safety education contents, development of contents, especially MSDS, and related things.

Thermal Environments of Children's Parks during Heat Wave Period (폭염 시 어린이공원의 온열환경)

  • Ryu, Nam-Hyong;Lee, Chun-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.6
    • /
    • pp.84-97
    • /
    • 2016
  • This study was to investigate the user's thermal environments of the children's parks according to pavements and sunscreen types during periods of heat waves. The measurements were conducted at the sand pits, rubber chip pavement, shelters, and green shade ground of the two children's parks located in Jinju, Korea(Chilam: $N\;35^{\circ}11^{\prime}1.4{^{\prime}^{\prim}}$, $E\;128^{\circ}5^{\prime}31.7{^{\prime}^{\prime}}$, elevation 38m, Gaho: $N\;35^{\circ}09^{\prime}56.8{^{\prime}^{\prime}}$, $E\;128^{\circ}6^{\prime}41.1{^{\prime}^{\prime}}$, elevation 24m) over three days during 11-13, August, 2016. The highest ambient air temperatures at the Jinju Meteorological Office during the three measurement days were $35.9{\sim}36.8^{\circ}C$, which corresponded with the extremely hot weather. A series of experiments measured air temperature, relative humidity, wind velocity, black globe temperature, and long-wave and short-wave radiation of the six directions 0.6 m above ground level. The wet bulb globe temperature(WBGT) and the universal thermal climatic index(UTCI) were used to evaluate thermal stress. Surface temperature images of the play equipment were also taken using infrared thermography. Surface temperatures of the play equipment and grounds were used to evaluate burn risk through contact with playground materials. The results showed the following. The maximum air temperatures averaged over 1-hour period for three days were $36.6{\sim}39.4^{\circ}C$. The sun shades reduced those temperatures by up to $2.8^{\circ}C$(green shade) and $1.0^{\circ}C/2.3^{\circ}C$(shelters). The minimum relative humidity values averaged over 1-hour period for three days were 44~50%. The sun shades increased those humidity values by up to 6%(green shade) and 4%/6%(shelters). The risk of heat related illness at the measurement sites of the children's parks were extreme and high in the daytime hours. The maximum WBGT values averaged over a 30-minute period for three days were $31.2{\sim}33.6^{\circ}C$. The sun shades reduced those WBGT values by up to $2.4^{\circ}C$(green shade) and $0.5^{\circ}C/2.1^{\circ}C$(shelters) compared to sandpits, but would not block the risk of heat related illness in the daytime hours. The category of heat stress at the measurement sites of the children's parks were extreme and very strong in the daytime hours. The maximum UTCI values averaged over a 30-minute period for three days were $39.9{\sim}48.1^{\circ}C$. The sun shades reduced those UTCI values by up to $7.8^{\circ}C$(green shade) and $4.1^{\circ}C/8.2^{\circ}C$(shelters) compared to sandpits, but could not lower heat stress category from extreme and very strong to strong and moderate in the daytime hours. According to the burn threshold criteria when skin was in contact with playground materials, the maximum surface temperature of the stainless steels($70.8^{\circ}C$) surpassed three seconds $60^{\circ}C$ threshold for uncoated steel, that of the rubber chip($76.5^{\circ}C$) surpassed five seconds $74^{\circ}C$ threshold for the plastic, that of the plastic slide($68.5^{\circ}C$) and seats($71.0^{\circ}C$) surpassed the one min $60^{\circ}C$ threshold for plastic, respectively. The surface temperatures of shaded play equipment were lower approximately $20^{\circ}C$ than those of play equipment exposed to the sun. Therefore, sun shades can block the risk of burns in daytime hours. Because of the extreme and high risk of heat related illness and extreme and high heat stress at the children's parks during periods of heat waves, parents and administrators must protect children from the use of playgrounds. The risk of burn when contact with play equipments and grounds at the children's parks during periods of heat waves, was very high. The sun shades are essential to block the risk of burn from play equipments and grounds at the children's parks during heat waves.