온실난방을 위한 히트펌프의 성능에 관한 연구 (A Study on the Greenhouse Heating Performance of Heat Pump System)

  • 윤용철;서원명;이석건
    • 한국농공학회지
    • /
    • 제40권3호
    • /
    • pp.94-102
    • /
    • 1998
  • This experiment was carried out to study on the effect of greenhouse heating by water-to-water heat pump system employing heating water tank(ground water) as the heat source. Followings are the results obtained from this study ; 1. The heat amount absorbed from evaporator and the heat amount rejected from condenser were approximately 9, 000~ 12, 000kcal/h and 13, 000~ 17, OOOkcal/h, respectively. 2. The heat efficiencies of evaporator and condenser used in this experiment were approximately 79% and 83%, respectively. 3. The maximum heating load estimated for the experimental greenhouse was about 18, 000 ~ 25, OOOkcal/h, which was found to be about 28 ~ 32% higher than the heating capacity of the heat pump system adopted for this experiment. 4. The coefficients of performance(COP) for the heat pump and the total heat pump system were approximately 2.9~3.5 and 1.5~2.4, respectively. 5. The coefficient of performance(COP) calculated from the Mollier Diagram was about 3.2 ~ 3.4, which was reasonably close to the COP estimated on the basis of measured values. 6. The temperature of experimental greenhouse heated by the heat pump system could be maintained about 12~15 。C higher than that of a control greenhouse.

  • PDF

물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구 (Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System)

  • 홍부표;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

정수장 내 축열조 설치 원수열원 히트펌프의 성능분석 (Studies on Raw-Water Source Heat Pump Equipped with Thermal Storage Tank in Water Treatment Facility)

  • 오선희;윤린;조용
    • 대한기계학회논문집B
    • /
    • 제37권5호
    • /
    • pp.467-472
    • /
    • 2013
  • 정수장 내 축열조 설치 원수열원 히트펌프시스템의 동적 특성을 TRNSYS 프로그램을 이용하여 모델링 하였다. 원수열원 히트펌프의 실증평가를 위해 성남정수장 내 축열조가 설치된 히트펌프 실험결과를 이용하여 검증하였고, 본 설비는 2010년 11월부터 운전되고 있다. 모델링 결과 원수열원 히트펌프의 평균 COP는 냉 난방 시 각각 4.97과 3.17을 나타냈다. 축열조 용량은 $5m^3$에서 $20m^3$로 변화시킬 때, 축열조 용량 $10m^3$ 에서 가장 높은 COP와 소비전력이 나타났다. 설치지역으로 서울, 인천, 강릉, 그리고 광주를 고려하였고, 지역에 따른 COP와 소비전력은 큰 변화가 없었으나 소비전력량에 있어서 난방 시에 위도가 높은 서울의 소비전력량이 가장 높으며, 냉방 시에 가장 낮게 나타났다. 본 시스템을 동일한 용량의 물-공기방식의 히트펌프와 비교할 때 평균 25%정도 낮은 소비전력량을 나타냈다.

수냉형 직렬방식 2중효용 흡수식 냉방기의 열해석과 최적 설계 (Thermal Analysis and Optimum Design of Water-Cooled, Series-Flow Type, Double-Effect Absorption Heat Pump)

  • 오명도;김영률;김선창;김영인
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.332-341
    • /
    • 1992
  • An absorption heat pump cycle has been modeled and simulated to analyze the system performance of water-cooled, series-flow, double-effect absorption heat pump, which can be applied to a direct gas fired cooling system with the medium range of cooling capacity (15RT level). Effect of absorption cooling system parameters, such as concentration difference, inlet temperature of cooling water, 1st generator temperature, leaving temperature differences of condenser and evaporator and efficiency of solution heat exchanger, has been investigated in the view of system cooling performance.