• Title/Summary/Keyword: 물 냉각기

Search Result 182, Processing Time 0.035 seconds

A Study on Direct Cooling and Washing Machine for Energy Saving-Type Dyeing Machine (에너지 절감형 염색기용 직접냉각수세장치에 대한 연구)

  • Han, Seung-Chul;Kim, Jin-Ho;Kim, Je-Hoon;Lee, Sung-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.485-491
    • /
    • 2012
  • Due to increase in production of the domestic textile industry, energy consumption in textile industry is still growing. Traditional dyeing machine has high temperature and pressure. Accordingly, it uses an indirect cooling system that utilize a heat exchanger to cool after the dyeing. However, this indirect cooling system consumes a great deal of water, takes prolonged periods of time to process and, most importantly, because of the condensing of the dye at the cooling stage requires further energy in reduction cleaning and washing process. Therefore, in this paper, we propose a direct cooling washing machine that replaces the traditional indirect cooling system to provide coolant into the dyeing machine. The newly proposed direct cooling washing machine will still use parts of the traditional dying but will be able to skip the cooling as well as the reduction cleaning and washing process, resulting in less processing time and lower energy consumption. Also, we made a prototype. The prototype was applied to dyeing machine to test the direct cooling washing machine's ability and dyeing property. Additionally, we compared indirect cooling washing machine with direct cooling washing machine about ability, material and energy saving assessment.

Optimization of the Scraper Speed and Improvement of the Refrigerant Path for the Evaporator of the Soft Ice Cream Machine (소프트 아이스크림 제조기 증발기의 스크레이퍼 회전수 최적화 및 냉매 유로 개선)

  • Baek, Seung-Hyuk;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.8-14
    • /
    • 2017
  • Improvements in the standard of living and lifestyle have led to increased sales of frozen milk products, such as soft ice cream or slush. These frozen milk products are commonly made in a small refrigeration machine. In a soft ice cream machine, the freezer is composed of a concentric cylinder, where the refrigerant flows in the annul us and the ice cream is made in the cylinder by a rotating scraper. In this study, an optimization and performance evaluation were conducted on a soft ice cream machine having a freezer volume of 2.8 liters. The optimization was focused on the scraper rotation speed and the refrigerant path of the freezer. The measurements included the temperature, pressure and consumed power. At the optimized speed of 124 rpm, ice cream was produced in 6 minutes and 2 seconds, and the COP was 0.90. Through a flow visualization study using air-water, the refrigerant path was improved. The improved design reduced the ice cream making time significantly. The present results may be used for the optimization of other refrigeration cycles, including those of frozen food products.

Cooling Performance Analysis of Regeneratively Cooled Combustion Chamber (재생냉각 연소실의 냉각성능 해석)

  • Cho, Won-Kook;Seol, Woo-Seok;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.67-72
    • /
    • 2004
  • A regenerative cooling system has been designed through empirical 1-D analysis for a liquid rocket engine of 30-ton-level thrust. The hot-gas-side wall temperature from 1-D analysis shows 100K difference compared to 3D CFD analysis. Two variations of design with same cooling performance are suggested for different maximum channel widths i.e., 4mm and 2mm. The coolant pressure drop of the latter design is higher by 20%. The maximum liner temperature is about 700K when TBC and the thermal resistance of carbon deposit are considered. So film cooling is recommended to increase the cooling capacity as the present cooling capacity is insufficient

Concept Development and Review of Current Technical Issues for SFR Steam Generator (소듐냉각 고속로용 증기발생기 기술분석 및 개념개발)

  • Nam, Ho-Yun;Kim, Jong-Bum;Lee, Jae-Han;Park, Chang-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.9
    • /
    • pp.1083-1090
    • /
    • 2011
  • A steam generator poses many difficulties during the development of a sodium-cooled fast reactor because of the sodium-water-reaction problems. Until now, several types of steam generators have been developed, but the specifications of these generators differed in each country. Moreover, even if a country had developed a steam generator, it was not used in the subsequent reactor because the current techniques were not stabilized to select the proper steam generator. As a common development, the Benson steam cycle with few welding locations and high economical efficiency may be adopted. Moreover, the design is dwelled on the convenience of inspection, detection, control, and maintenance for the wear caused by sodiumwater reactions. The specifications of the designed steam generators were reviewed and the current technical problems for steam generators were analyzed. Concepts were proposed to overcome the current technical problems for steam generators.

Design Concept and Technology Development of a Double-Wall-Tube Steam Generator (이중벽관 증기발생기의 설계개념 기술개발)

  • Nam, Ho-Yun;Choi, Byoung-Hae;Kim, Jong-Bum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1217-1225
    • /
    • 2010
  • The possibility of a sodium-water reaction occurring in a conventional single-wall-tube steam generator in an SFR is a major problem. To improve the reliability of a steam generator, a double-wall-tube steam generator that can reduce the possibility of the occurrence of a sodium-water reaction is being developed. Current developments are focusing on improving the heat-transfer capability of a double-wall tube; further, the development of a leak-detection method to detect the occurrence of a sodium-water reaction during the reactor operation is also underway. In this study, new concepts, which will solve the above-mentioned problems, have been developed. Accordingly, a double-wall tube has been designed, fabricated, and mechanically tested for the purpose.

Overview of In-Vessel Retention Concept With Application to an Advanced Pressurized Water Reactor-Design (용기내부보존 개념의 조감 : 신형가압경수로원전-설계적용의 관점에서)

  • 김성호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.592-599
    • /
    • 1997
  • 중대사고관리 전략의 하나로서 피동형-설계에 적용되고 있는 용기내부보존(IVR)기념 - 이 논문에서는 실제적으로 원자로 압력용기벽 외부냉각(ERVC)방법을 사용한다 -이 규제측면에서는 용융물의 냉각가능성 쟁점의 해결이라는 문맥에서 조감되었다; 기술측면에서는 IVR개념의 신빙성 및 유융성이 언급되었다. 덧붙여서, 이 ERVC방법들이 개량형-설계에 적용되기 위하여 요구되는 점들이 규제측면과 기술측면에서 각각 검토되었다. 이 검토결과의 바탕위에서 용융물 냉각가능성/급냉가능성의 쟁점과 관련하여 전력연구원(KEPRI) 신형원전개발센타(CARD)에서 개발중인 한국차세대원전(KNGR)-설계에서 선택될 수 있는 대안적 전략들이 제안되었다: (1) 전략1A: 젖은공동방법의 신빙성에 기반을 두는 것; (2) 전략1B: 젖은공동방법/격납건물건전성에 기반을 두는 것; (3) 전략2A : ERVC방법의 신빙성에 기만을 두는 것, (4)전략2B: ERVC방법/격납 건물건전성의 균형된 접근법에 기반을 두는 것. 마지막으로, 신형-설계적용의 관점에서 각각 규제측면과 기술측면에서 본 현황파악 및 대책마련의 권고사항이 제시되었다.

  • PDF

Low Pressure Firing Tests of 75-tonf-Class Channel Cooling Thrust Chamber (75톤급 채널냉각 연소기 저압연소시험)

  • Lim, Byoung-Jik;Han, Yeoung-Min;Kim, Jong-Gyu;Seo, Seong-Hyeon;Ahn, Kyu-Bok;Kim, Mun-Ki;Lee, Kwang-Jin;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.71-74
    • /
    • 2010
  • Using the technology demonstration model of 75-tonf-class combustor which is expected to be used to the rocket engine of a korean space launch vehicle, 2 times of firing tests were carried out. Firing tests were done at 50% of the nominal flow rate because of incapability of the test facility and limit of the test bed strength. Through the low pressure firing tests of 75-tonf-class channel cooling thrust chamber, reliability and stability at the ignition and combustion phases were confirmed. Additionally it was foreseen that the 75-tonf-class thrust chamber would satisfy the performance requirements.

  • PDF

A Simulation Method for Predicting the Performance and the NOx Level of Gas Turbine System (가스터빈 시스템의 성능 및 NOx 배출 예측을 위한 모사방법)

  • Lee, Han-Goo;Kang, Seung-Jong;Lee, Chan
    • Journal of Energy Engineering
    • /
    • v.3 no.1
    • /
    • pp.28-35
    • /
    • 1994
  • 가스터빈 사이클의 성능 및 NOx 배출물 생성량 예측을 위한 모사 프로그램을 개발하였다. 압축기 및 터빈은 등엔트로피 과정으로, 연소기는 Thermal NOx 생성을 수반하는 연소모형으로서 가정하였다. 또한 터빈 냉각을 위한 추출공기량과 냉각방식이 성능에 미치는 적절한 상관 관계식을 도입하여 평가하였다. 본 성능평가 모델을 이용하여 예측된 결과와 실험결과간의 비교를 통하여 모델의 타당성을 검증하였고, 증기 분사량, 터빈 냉각변수 및 압축비 변화에 따른 예측결과를 통하여 가스터빈 시스템 최적 운전 및 설계기준을 제시하였다.

  • PDF

A Study on Particulate Behavior of Nickel Ferrite (니켈 페라이트의 입자 거동 연구)

  • Ku, Hee-Kwon;Park, Byung-Gi;Kim, Jong-Yung;Jeong, Eun-Sun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.365-367
    • /
    • 2008
  • 원자로 냉각계통의 압력경계를 구성하고 있는 재료들의 부식은 재료 표면에 형성되는 산화막, 금속재료의 구성성분이 용해되어 생성된 가용성 화학종 및 산화물 입자 형태의 부식생성물들을 발생시킨다. 금속합금의 부식에 의한 가용성 화학종 및 입자들의 방출은 원자로 냉각계통에서 노심과 증기발생기를 순환하면서 연료피복관 위에 침전되어 여러 가지 문제를 야기한다. 크러드는 구조재료의 부식에 기인하여 발생한 부식생성물들이 냉각수에 부유하여 떠다니거나 피복관 표면에 침적하여 형성되며 주로 니켈과 철 산화물로 구성되어 있다. 원자로 냉각계통에서 크러드를 최소화하기 위하여 수화학 조건들을 제어하지만 장주기 고연소도 노심에서 AOA 현상을 일으키는 주된 원인이 되고 있다. 피복관 위에 침적되는 크러드는 붕소의 잠복위치를 제공할 뿐만 아니라 냉각수의 압력강하를 증가시키고 피복관의 부식 및 파손 원인을 제공하며 방사선 준위가 증가하도록 한다. 따라서 본 연구에서는 반응속도론적 관점에서 원자로 정지시의 용출 크러드 특성에 대한 연구를 수행하였다.

  • PDF

Control of Hot Spots in Plug Flow Reactors Using Constant-temperature Coolant (등온 냉각액을 활용한 plug flow reactor 내의 과열점 제어를 위한 제어모델 개발)

  • Rhyu, Jinwook;Kim, Yeonsoo;Lee, Jong Min
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.77-84
    • /
    • 2021
  • To control hot spot in a plug flow reactor (PFR) is important for the yield and purity of products and safety. In this paper, coolant temperature is set as a state variable, and radial distributions of heat and mass are considered to model the PFR more realistic than without considering radial distributions. The model consists of three state variables, reactant concentration, reactant temperature, and the coolant temperature. The flow rate of the isothermal coolant is a manipulated variable. This paper shows that the controller considering the radial distributions of heat and mass is more effective than the controller without them. Assuming that u3,0 is 0.7, the suggested control equation was robust when St is bigger than 1.3, and Ac/A is smaller than 2.0. Under this condition, the hot spot temperature changed within the relative error of one percent when the temperature of input altered within the range of five percent.