• Title/Summary/Keyword: 물세척

Search Result 448, Processing Time 0.173 seconds

Treatment of Korean Medical Herb Extracts Affects the Quality Characteristics of Vegetables (대황 및 황련추출물 처리에 따른 시설채소산물의 품질특성 변화)

  • 박우포;조성환
    • Food Science and Preservation
    • /
    • v.6 no.3
    • /
    • pp.276-280
    • /
    • 1999
  • To maintain the quality characteristics of vegetables, produce was dipped in Korean medical herb extracts (KMHE) such as Rheum palmatum L. or Coptis chinensis Franch with different concentration. Dipping in 500 ppm KMHE solution was suitable for the reduction or microbial load on cucumber, and 100 ppm KMHE solution was appropriate for others. Dipping time was suitable for produce about 10 minutes, and the temperature of dining solution had a limited effect cm the microbial load reduction. Antimicrobial activity of Coptis chinensis Franch and Rheum palmatum L. was maintained for cucumber and zucchini wrapped with polyvinylchloride film during storage at 10$^{\circ}C$.

  • PDF

THE COMPARISON OF DIFFERENT CANAL IRRIGATION METHODS TO PREVENT REACTION PRECIPITATE BETWEEN SODIUM HYPOCHLORITE AND CHLORHEXIDINE (차아염소산나트륨과 클로르헥시딘의 반응침전물 형성방지를 위한 여러 가지 근관세척 방법의 비교)

  • Choi, Moon-Sun;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.80-87
    • /
    • 2010
  • The purpose of this study was to compare the different canal irrigation methods to prevent the formation of precipitate between sodium hypochlorite (NaOCl) and chlorhexidine (CHX). Extracted 50 human single-rooted teeth were used. The root canals were instrumented using NiTi rotary file (Profile .04/#40) with 2.5% NaOCl and 17% EDTA as irrigants. Teeth were randomly divided into four experimental groups and one control group as follows; Control group: 2.5% NaOCl only, Group 1: 2.5% NaOCl + 2% CHX, Group 2: 2.5% NaOCl + paper points + 2% CHX, Group 3: 2.5% NaOCl + preparation with one large sized-file + 2% CHX, Group 4: 2.5% NaOCl +95% alcohol+ 2% CHX. The teeth were split in bucco-lingual aspect and the specimens were observed using Field Emission Scanning Electron Microscope. The percentages of remaining debris and patent dentinal tubules were determined. Statistical analysis was performed with one-way analysis of variance (ANOVA). Energy Dispersive x-ray Spectroscopy was used for analyzing the occluded materials in dentinal tubule for elementary analysis. There were no significant differences in percentage of remaining debris and patent tubules between all experimental groups at all levels (p > .05). In elementary analysis, the most occluded materials in dentinal tubule were dentin debris. NaOCl/CHX precipitate was detected in one tooth specimen of Group 1. In conclusion, there were no significant precipitate on root canal, but suspected material was detected on Group 1. The irrigation system used in this study could be prevent the precipitate formation.

농약에 의한 과채류오염 지나친 편견이다.

  • 이해근
    • The Bimonthly Magazine for Agrochemicals and Plant Protection
    • /
    • v.7 no.3
    • /
    • pp.11-22
    • /
    • 1986
  • 잔류농약의 대부분은 표면에 잔류하기 때문에 단순한 물세척으로도 마라톤의 경우 고추와 포도에서 각각 75$\%$ 및 90$\%$가 제거되고 주방용 세제를 이용하면 각각 92$\%$ 및 98$\%$가 제거된다

  • PDF

Change of Harmful Micnoorganisms in Pickling Process of Salted Cabbage According to Salting and Washing Conditions (배추김치의 절임공정 조건에 따른 위해미생물 변화)

  • Kim, Jin-Hee;Lee, Yu-Keun;Yang, Ji-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.417-423
    • /
    • 2011
  • Salted Cabbage products purchased from different companies at 4 different districts in South Korea were detected in this study. Cabbage and salt are the main materials for kimchi manufacture. The results of general bacteria contaminated in the samples were $1.4{\times}10^5$, $6.4{\times}10^5$, $1.7{\times}10^7$, $3.6{\times}10^7$ CFU/g in cabbage and $2.7{\times}10^3$ CFU/g in salt, respectively. The results of coliforms were detected as $2.4{\times}10^4$ CFU/g, and there was no Escherichia coli in any sample. Staphylococcus aureus was detected in cabbage as $9.9{\times}10^2$, $8.0{\times}10^1$, and $3.0{\times}10^3$ CFU/g, Bacillus cereus was also found in cabbage as $4.1{\times}10^3$ and $1.0{\times}10^1$ CFU/g. The results of Campylobacter jejuni and Vibrio paraheamolyticus were $2.4{\times}10^6$ and $1.0{\times}10^4$ CFU/g in cabbage, respectively. $1.0{\times}10^3$ CFU/g for Yersinia enterocolitica was determined in salt. In case of Listeria monocytogenes, the results were $1.5{\times}10^1$, $1.1{\times}10^2$, and $4.5{\times}10^1$ CFU/g in cabbage. Total batcteria ranged from $1.4{\times}10^1$ to $4.4{\times}10^5$ CFU/g were detected in salting solution, from $1.5{\times}10^4$ to $1.2{\times}10^8$ CFU/g in dehydrated salted-cabbage, from $9.4{\times}10^4{\sim}1.3{\times}10^8$ CFU/g in minced salted-cabbage. The results of E. coli in samples from different companies were different from one to anther. The results of the contamination of S. aureus and B. cereus showed positive in salting solution and dehydrated salted-cabbage at a portion of companies. V. paraheamolyticus was detected in salting solution. The contamination of Y. enterocolitica ranged from $9.5{\times}10^2$ to $1.8{\times}10^3$ CFU/g in salting solution, from $1.7{\times}10^1$ to $2.7{\times}10^2$ CFU/g in dehydrated salted-cabbage, from $1.2{\times}10^2$ to $1.3{\times}10^8$ CFU/g in minced salted-cabbage. The contamination of L. monocytogenes ranged from $8.0{\times}10^2$ to $1.7{\times}10^4$ CFU/g in salting solution, from $2.8{\times}10^2$ to $1.2{\times}10^4$ CFU/g in dehydrated salted-cabbage. During the manufacture processing of Kim chi, microorganisms were detected in cabbages salted in different concentrations of salt solution at 8%, 10%, 12% and 15% for 5-20 hours. As the results, $3.5{\times}10^5-1.7{\times}10^6$, $3.4{\times}10^5-2.5{\times}10^6$, $5.4{\times}10^5-2.3{\times}10^6$, $4.0{\times}10^5-2.3{\times}10^6$ CFU/g were detected for E. coli in samples at different treatment conditions. $1.9{\times}10^4-4.1{\times}10^4$, $4.1{\times}10^3-2.8{\times}10^4$, $1.5{\times}10^3-7.8{\times}10^3$, $2.2{\times}10^4-6.6{\times}10^4$ CFU/g were detected for S. aureus in samples at different treatment conditions. Salmonella typhimurium was detected in salted cabbage with various salt concentration after salting for 5 hrs, the result ranged from $2.5{\times}10^5$ to $3.8{\times}10^6$ CFU/g, and change of microorganism was the smallest in salted cabbage under the concentration of salting solution at 10% for 15 hours. The cabbage salted in 10% salting solution for 15 hours were washed with water for 2 and 3 times, with chlorine for 3 times, and with acetic acid for 3 times. E. coli was detected in the samples washed with water for 2 and 3 times, washed with chlorine for 3 times. The contamination of S. aureus was $3.0{\times}10^5$ CFU/g in the samples washed with water for 2 times, $5.6{\times}10^3$ CFU/g in the samples washed with acetic acid for 3 times, $3.6{\times}10^5$ CFU/g in the samples washed with water for 3 times and same amount in the samples washed with chlorine for 3 times. According to the results, the contamination of S. aureus was $5.6{\times}10^3$ CFU/g lower in samples washed with chlorine and acetic acid than that in samples washed with water. In case of S. typhimurium, it has been detected in samples washed with water and chlorine, $3.0{\times}10^1$ CFU/g as the lowest concentration among all the samples was measured in the samples washed with acetic acid for 3 times.

Concentrating Effect of Heavy Metals from Heavy Metal Contaminated Soil by Magnetic Separation (중금속오염 토양의 자기분리에 의한 오염농축효과)

  • Kim, Jee-Eun;Kim, Jeong-Jin;Kim, Young-Hun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.311-320
    • /
    • 2014
  • A magnetic separation study was conducted for a soil sampled from a landfill site where steel slag had been dumped for a long time. Heavy metal concentrating effect was evaluated by analyzing heavy metal content of magnetically separated soil and passed through soil. The effect was compared between soil after soil-washing process and original landfill soil and the effect was also tested between wet condition-magnetic separation and dry condition-magnetic separation. Separated ratio was relatively higher in non-soil washed sample. The water content has no significant effect on the separation rate. The concentrating effect of Fe, Pb, Cu, and Cd were 3.2, 2.1, 12.1, 2.5, 1.5 and 17.4, 7.0, 15.7, 9.6, 7.0 respectively for non-soil washed sample and soil washed sample. We can expect a bigger volume reduction effect from soil-washed samples. The volume reduction effect was obtained from the separation in dry condition. However, when the separation ratio is too high the volume reduction effect decreases. The magnetic separation leads to a volume reduction and concentration of heavy metals into a portion of soil in case of paramagnetic particles contained soil.

Effect of Interfacial Properties on the Detergency in Dishwashing Agent Composition (식기용 세정제 조성에 있어서 계면물성이 세정력에 미치는 영향)

  • Oh, Hyun-Joo;Lim, Hyo-Seon;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.193-199
    • /
    • 2020
  • The effects of the composition of the dishwashing detergent on interfaces of the oil (O) and the aqueous (W) solution in addition to the cleaning effects of interfacial properties were investigated. Also, the cleaning power of the oil contaminated on the surface of the dish according to each composition and the residuals of the contaminants and the cleaning agent after the washing rinses were evaluated. The removal of contaminated oil on the solid (S) surface in the composition of the cleaning agents used in this study was strongly related to the interfacial properties between the W/O/S, and was particularly dependent on the forward and backward dynamic contact angles. When both contact angles were low at the same time, the permeability of the cleaning solution was so high that the contaminated oil showed a high removal effect. The smaller the interfacial tension of O/W was, the better emulsification of the contaminated oil, the higher the interfacial tension, and the poorer emulsification were achieved. However, the emulsification effect did not significantly affect the cleaning power. In particular, in the case of the cleaner having low interfacial tension, the cleaning material remained on the surface of the solid after washing.

Initial Operating Condition of Membrane Bioreactor with PVDF Hollow Fiber and Permeate Reuse (PVDF 중공사막을 이용한 막생물반응기의 초기 운전조건 설정 및 여과수 재활용)

  • Shin, Choon-Hwan;Kang, Dong-Hyo;Park, Hae-Sik;Cho, Hyun-Kil
    • Clean Technology
    • /
    • v.16 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • In this paper, 4 bundle modules of PVDF hollow fiber membrane from Woori Tech company (Korea) were manufactured in a treatment capacity of 10 ton/day. A membrane bioreactor (MBR) pilot plant was installed at Sooyoung Wastewater Treatment Plant in Busan. An alternating aeration process was selected to avoid the concentration profile of suspended solid (SS) in the MBR. For stable operation, raw wastewater with mixed liquor suspended solid (MLSS) of about 1,000 ppm, which was in-flowed from the aeration tank of the wastewater treatment plant, was fed and filtered through the pilot plant. Subsequently the pilot plant were washed three times with washing water: once with ethanol solution, once with a solution of 5% NaOCl, and finally with washing water. After the chemical washing, the remaining water in the MBR was fed into the pilot plant. As a result, the SS removal efficiency was found to be more than 99.9%. The amount of filtrate with the aeration tank influent decreased by 16%, compared with that from the initial conditions, giving rise to 30% increase in the suction pressure. These results were used to set up continuous operation conditions. The results from the continuous operation with influent MLSS of 1,900 mg/L showed that the SS removal efficiency was about 99.99% and that the amount of filtrate and the suction pressure were $42{\sim}52L/m^2$ and 16~20 cmHg, respectively, indicating stable operation of the pilot plant. However, for the reuse of wastewater, methods need to be sought to avoid growth of algae which affects the SS removal efficiency at inlet and outlet of the permeate tank.

Conservation of Removing Surface Contaminants on Silla monument at Jungsung-ri using Nd:YAG Laser Cleaning System (Nd/YAG레이저를 이용한 포항중성리신라비 표면오염물 제거와 보존처리)

  • Lee, Tae Jong;Kim, Sa Dug;Lee, Joo Wan;Oh, Jung Hyeon;Lee, Myeong Seong
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.4
    • /
    • pp.142-153
    • /
    • 2011
  • 'Silla Monument Stone in Jungseong-ri, Pohang' was discovered in Pohang City, Gyeongsangbuk Province of Korea in 2009. The monument stone with irregular shape has dimensions of maximum height of 105cm, width of 47.6~49.6cm, thickness of 13.8~14.7cm and weight of 115kg. The results of monument stone was found to be granitite. Conservation treatment procedure was carried out in the order of production of Weathering map, cleaning of surface pollutants, consolidation using ethyl silicate. Black pollutant(crust) that covered more than 60% of the surface was analyzed first in order to remove the pollutants on the surface of the monumental stone by cleaning of surface pollutants using laser. The purpose on analysis was not only to verify the pollutants on the stone but also to carry out preliminary cleaning by securing rocks with same pollutant as the monumental stone. As the results of analysis using p-XRF(PMI. INNOV-X, USA) on the site, high level of Mn and Fe were detected, and the analysis of small section that had been fallen off with SEM/EDX for the purpose of quantitative analysis also detected high level of Mn. The Similar contaminants on Stone secured in the manner described above were made into 10 samples ($5cm{\times}5cm$) and was subjected to preliminary cleaning by Nd-YAG Laser(Laser&Physics, Korea). The results of surface observation through portable microscope during cleaning revealed that the power of 460mJ, wavelength of 1064nm and irradiation frequency of 1,800~2,300 per $25cm^2$ were most effective. Evaluation on the preservative treatment was made through confirmation of the extent of removal through color-difference meter measurement and component analysis prior to and following removal of the pollutants. As the result of color-difference meter measurement increase in the brightness was evidenced by the increase in the brightness ($L^*$)value from 33 to 49, and it was possible to ascertain the reduction in the pollutants as the content of Mn was reduced by about 80% from $50,000{\pm}5,000ppm$ to $10,000{\pm}2,000pmm$ from the result of component analysis.