• Title/Summary/Keyword: 물리적환경 변화

Search Result 1,386, Processing Time 0.034 seconds

Jeju Shinyang Fishing Port Remodeling Plan Utilizing Marine Tourism Resources (해양관광자원을 활용한 제주 신양항 리모델링 계획)

  • Kim, Yelim;Sung, Jong-Sang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.2
    • /
    • pp.52-69
    • /
    • 2016
  • The fishing port was once the foothold of production as well as the stronghold of communities but with the declining of the fishing industry, ports became abandoned space. Jeju Special Self-Governing Province has continued its effort to vitalize marine tourism since 2010. Shinyang Port in particular is designated as a Prearranged Marina Port Development Zone, and planning for the Jeju Ocean Marina City project is underway. Nevertheless, fishing port remodeling projects implemented on Jeju so far have focused only on civil engineering such as renovating old facilities. In addition, most Marina Port Development Projects have been irrelevant to local communities. Leading projects by the local government mostly suffer from a lack of funding, which results in the renovation of old facilities and improper maintenance, while private sector investment projects do not lead to benefit sharing with the community. Shinyang Port, also renovated in 2008, ended up with outer breakwater extension construction that neither solved the fundamental problem of the site nor gave benefits to residents. To arrange a way to solve problems for civil engineering focused development project, improper maintenance, and benefit sharing with community, first, this study proposes a development plan that connects with the outlying areas near the ports. The plan reflects existing topography, Jeju traditional stonewalls, narrow paths on the master plan and programs by reading the regional context. In this way, this paper suggests a space development plan reflecting the local landscape and characteristic factors. Second, it satisfies various needs by using existing and new Marine Tourism Resources. Third, it examines sustainable operation and management measures through residents' participation. The proposal is significant in two key ways: it is a fresh attempt at connecting the fishing port with its outlying areas from a landscape perspective; and it considers environmental, social, economic issues, and suggests participation for local communities. Thus, the model can be used in future fishing-port remodeling plans for revitalizing unused space, including invaluable traditional landscapes, and for boosting the marine-leisure industry.

Determination of Soil Phosphorus and Zinc Interactions using Desorption Quantity-Intensity Relationships (탈착 유효량과 가용량의 연관성을 이용한 토양 인산과 아연의 상관 관계 측정)

  • Lee, Jin-Ho;Doolittle, James J.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.2
    • /
    • pp.59-65
    • /
    • 2004
  • Interactions of phosphorus and zinc in soils are important to determine the availability of the elements because those elements are closely related in the agricultural environment. The objective of this study was to investigate the interactions of P and Zn using desorption quantity (Q)-intensily(I) isotherms. Physically and chemically different soils, acidic Egan, acidic sandy Egeland, calcareous Glenham, and neutral Maddock, were used. The soils were enriched with different concentrations of P and Zn as $KH_2PO_4$ and $ZnSO_4$ solutions, respectively. Zinc enrichments affected availability of P in the Egan soil, which contained higher amounts of clay, organic matter, and exchangeable Fe than the other soils tested. After Zn enrichments, the pH drastically decreased in Egeland sandy soil, not changed in the calcarious Glenham soil, and slightly decreased in Egan and Maddock soil systems. The values of $Q_{max}$ and $I_0$ of phosphorus decreased with increasing Zn concentrations enriched in all soils, the changes of those values did not influence the P buffering power, |$BP_o$| values, in most soils. The influences of P treatment on Zn availability were varied. The values of Zn buffering capacity, $BC_{Zn}$, were lowest in the Egeland soil that had the lowest soil pH, amounts of clay minerals, organic matter, CEC, and exchangeable Fe, and were highest in the calcareous Glenham soil. The $BC_{Zn}$ values ranged from 202 to 4480. With P application, the changes of $BC_{Zn}$ values were more affected by the changes of soil solution Zn contents (I) than the changes of DTPA extractable Zn contents(Q). The change of Q and I values was found to be dependent upon soil properties, especially, soil pH.

A COMPARATIVE STUDY OF WATER ABSORPTION AND RELATED CHANGES OF COMPRESSIVE STRENGTH IN THREE RESTORATIVE MATERIALS (치과용 수복재의 수분흡수도와 압축강도의 변화에 관한 연구)

  • Chang, Woo-Hyuck;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.161-170
    • /
    • 2003
  • The aesthetic restorative materials are widely used in recent dentistry, showed not only the different quality between each component but also showed that the environment of the material has important effect on the physical properties of the material. Especially, when the restoratives are restored in the mouth, and since saliva is existing, the restoratives are always exposed to water and affected by the saliva. The purpose of this study was to research and compare the change of the degree of water sorption after water immersion of three types of the resin-based materials and the compressive strength, and observe the relation between the change of the water absorbing degree and the compressive strength. Z-100(3M, U.S.A) as a composite resin, F-2000(3M, U.S.A) as a compomer and Vitremer Restoratives(3M, U.S.A) as a resin-modified GIC were used, and each specimen was made to measure the water sorption and to evaluate the compressive strength. The specimens for measurement of the water sorption and the compressive strength were divided into 4 groups(1 day, 2 weeks, 4 weeks, and 8weeks). Each specimen was filled in the 30cc vial with 20cc of distilled water during the fixed amount of period in $37^{\circ}C$. The water sorption is decided by dividing the difference of weight before and after the immersion by the volume, and the compressive strength was measured by using the instron after the immersion. The following results were obtained ; 1. The more the water sorption increased, the more the immersion period of three restorative materials was long. And the most of water sorption was obtained during the first 2 weeks(P<0.001). 2. The water sorption of resin-modified GIC was higher than composite resin and compomer. 3. The more the compressive strength decreased, the more the immersion period of three restorative materials increased(composite resin and compomer: P<0.001, resin-modified GIC: P<0.05). Especially, the amount of the reduction in compressive strength of the composite resin was the highest. 4. The more the water sorption of all materials increased, the more the compressive strength decreased(P<0.05).

  • PDF

A Comparative Study on Performances and Carcass Traits in Three Major Meat-Type Duck Strains in Korea (국내 사육되는 육용오리 세 가지 계통의 생산성 및 도체 특성 비교 연구)

  • Bang, Han-Tae;Na, Jae-Cheon;Choi, Hee-Chul;Chae, Hyun-Seok;Kang, Hwan-Ku;Kim, Dong-Wook;Kim, Min-Ji;Suh, Ok-Suk;Park, Sung-Bok;Choi, Yang-Ho
    • Korean Journal of Poultry Science
    • /
    • v.37 no.4
    • /
    • pp.389-398
    • /
    • 2010
  • The present experiment was carried out to compare performance, carcass characteristics and meat quality among three major meat-type duck strains in Korea. Two commercial duck (CD) strains, produced from parent stocks (PS) (Cherry Valley and Grimaud), and $F_1$ strains, self-produced by farmers, were used in an 8-week feeding experiment. Both feed conversion ratio and production index were significantly higher in Cherry Valley strain compared with the other two at the ends of 6 and 8 weeks (p<0.05). However, no differences were found in carcass characteristics and meat quality, with the exception of abdominal fat weight where Grimaud were higher than the others. Overall, the results of the current study show that Cherry Valley CD strain had higher performance among three strains tested.

Historical Studies on the Characteristics of Jondeokjeong in the Rear Garden of Changdeok Palace (창덕궁 후원 존덕정(尊德亭)의 조영사적 특성)

  • Song, Suk-Ho;Sim, Woo-Kyung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.1
    • /
    • pp.31-43
    • /
    • 2014
  • The purposes for this research were to find the correct building background of Jondeokjeong(尊德亭) in the rear garden of Changdeok Palace(昌德宮) based on the historical facts for the area of Jondeokjeong and investigate the internal theory of construction through the metaphysical consideration. The results were as follows. 1. Building background of Jondeokjeong was related to Sohyunseja(昭顯世子) and Bongrimdaegun(鳳林大君) as forms of rear garden where was not built in the area of Jondeokjeong, bamboo pavilion, hexagonal pavilion, octagonal pavilion, etc. They were built two or three times after returning of Sohyunseja and Bongrimdaegun from China, and the area of Jondeokjeong was continuously developed by building Chunhyanggak(天香閣), Mangchunjeong(望春亭) and Cheoknoidang(滌惱堂) after Hyojong(孝宗) succeeded the royal authority of Hyunjong(顯宗) who was born in Shenyang(瀋陽) and hung a signboard of Jondeokjeong after then, etc. 2. Dazhengjeon(大政殿) of Shenyang Palace(瀋陽故宮, 1625) played the roles of major hall, Jeongjeon(正殿) which held national big events as a one-storied building with two piles of roof similar with Jondeokjeong (1644). Also, it was the building encountered when Sohyunseja and Bongrimdaegun participated in breakfasts held in the palace or banquets supervised by a king, so building background of Jondeokjeong was judged to be related with Dazhengjeon. 3. In consideration of characteristics which are shown commonly in Jondeokjeong and Dazhengjeon, relations of two buildings were verified and characteristics of Jondeokjeong were examined. First, dragon which is representatively symbolizing royal authority was formed. Therefore, Jondeokjeong was judged as a garden building which purposes were to obtain and train natural reasons, govern the nation and let people comfortable. Second, the purposes of sun dial, Ilyoungdae(日影臺) were judged to examine the accurate time and express appropriateness of the king. Third, Taechungmun(太淸門) around there is related to Samcheong(三淸) of Taoism and judged to be caused by floral wall and secular happiness accomplishment for king's longevity without disease. Fourth, for building style, one-stories pavilion of duplicated roof and building with only cylinder were to king's embodiment of supporting the sky and governing the nation.4) 4. By examining the differences between Jondeokjeong and Dazhengjeon, Jondeokjeong's own characteristics were considered. First, constructive characteristics of Jondeokjeong were changed by existing of pond and it was changed for characteristics, location and function of pavilion built in the garden while accepting oversea culture and embodied by absorbing to Joseon culture. Second, the appearance of the pond in Jondeokjeong was shown as the situation that half moon typed pond with the form of young moon is full by stream to the East. It was to express movement of moon which was always changed through the form of pond and stream of water iconographycally and it was considered as an imaginary environment method of the period.

Evaluation of CH4 Flux for Continuous Observation from Intertidal Flat Sediments in the Eoeun-ri, Taean-gun on the Mid-western Coast of Korea (서해안 태안 어은리 갯벌의 연속관측 메탄(CH4) 플럭스 특성 평가)

  • Lee, Jun-Ho;Rho, Kyoung Chan;Woo, Han Jun;Kang, Jeongwon;Jeong, Kap-Sik;Jang, Seok
    • Economic and Environmental Geology
    • /
    • v.48 no.2
    • /
    • pp.147-160
    • /
    • 2015
  • In 2014, on 31 August and 1 September, the emissions of $CH_4$, $CO_2$, and $O_2$ gases were measured six times using the closed chamber method from exposed tidal flat sediments in the same position relative to the low point of the tidal cycle in the Eoeun-ri, Taean-gun, on the Mid-western Coast of Korea. The concentrations of $CH_4$ in the air sample collected in the chamber were measured using gas chromatography with an EG analyzer, model GS-23, within 6 hours of collection, and the other gases were measured in real time using a multi-gas monitor. The gas emission fluxes (source (+), and sink (-)) were calculated from a simple linear regression analysis of the changes in the concentrations over time. In order to see the surrounding parameters (water content, temperature, total organic carbon, average mean size of sediments, and the temperature of the inner chamber) were measured at the study site. On the first day, across three measurements during 5 hours 20 minutes, the observed $CO_2$ flux absorption was -137.00 to $-81.73mg/m^2/hr$, and the $O_2$ absorption, measured simultaneously, was -0.03 to $0.00mg/m^2/hr$. On the second day using an identical number of measurements, the $CO_2$ absorption was -20.43 to $-2.11mg/m^2/hr$, and the $O_2$ absorption -0.18 to $-0.14mg/m^2/hr$. The $CH_4$ absorption before low tide was $-0.02mg/m^2/hr$ (first day, Pearson correlation coefficient using the SPSS statistical analysis is -0.555(n=5, p=0.332, pronounced negative linear relationship)), and $-0.15mg/m^2/hr$ (second day, -0.915(n=5, p=0.030, strong negative linear relationship)) on both measurement days. The emitted flux after low tide on both measurement days reached a minimum of $+0.00mg/m^2/hr$ (+0.713(n=5, p=0.176, linear relationship which can be almost ignored)), and a maximum of $+0.03mg/m^2/hr$ (+0.194(n=5, p=0.754, weak positive linear relationship)) after low tide. However, the absolute values of the $CH_4$ fluxes were analyzed at different times. These results suggest that rate for $CH_4$ fluxes, even the same time and area, were influenced by changes in the tidal cycle characteristics of surface sediments for understanding their correlation with these gas emissions, and surrounding parameters such as physiochemical sediments conditions.

A Study of Radiation Exposure in Proton Therapy Facility (양성자치료기 가속기 시설에서의 작업종사자의 방사선 피폭 연구)

  • Lee, Sang-Hoon;Shin, Dong-Ho;Yoon, Myong-Geun;Shin, Jung-Wook;Rah, Jeong-Eun;Kwak, Jung-Won;Park, Sung-Yong;Shin, Kyung-Hwan;Lee, Doo-Hyun;Ahn, Sung-Hwan;Kim, Dae-Yong;Cho, Kwan-Ho;Lee, Se-Byeong
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2009
  • Proton therapy facility, which is recently installed at National Cancer Center in Korea, generally produces a large amount of radiation near cyclotron due to the secondary particles and radioisotopes caused by collision between proton and nearby materials during the acceleration. Although the level of radiation by radioisotope decreases in length of time, radiation exposure problem still exists since workers are easily exposed by a low level of radiation for a long time due to their job assignment for maintenance or repair of the proton facility. In this paper, the working environment near cyclotron, where the highest radiation exposure is expected, was studied by measuring the degree of radiation and its duration for an appropriate level of protective action guide. To do this, we measured the radiation change in the graphite based energy degrader, the efficiency of transmitted beam and relative activation degree of the transmission beam line. The results showed that while the level of radiation exposure around cyclotron and beam line during the operation is much higher than the other radiation therapy facilities, the radiation exposure rate per year is under the limit recommended by the law showing 1~3 mSv/year.

  • PDF

Characteristics of Soil Disturbance Caused by Passages of Harvester and Forwarder in Cut-to-Length Harvesting Operations (단목생산작업에 있어서 하베스터와 포워더의 임내주행에 따른 토양교란 특성)

  • Han, Sang-Kyun;Lee, Kyeong-Cheol;Oh, Jae-Heun;Mun, Ho-Seong;Lee, Sang-Tae;Choi, Yun-Sung;Choi, Byoung-Koo
    • Journal of Korean Society of Forest Science
    • /
    • v.108 no.1
    • /
    • pp.67-76
    • /
    • 2019
  • With an increasing demand of timber production, the use of heavy machinery in forest management has significantly increased, causing the changes of soil physical properties and the decline of long-term site productivity. This study was conducted to evaluate the effects of logging slash (non-slash, slash $7.3kg/m^2$, and slash $11.5kg/m^2$) and machine passes(harvester 1 pass and forwarder 1 to 10 passes) on soil physical properties at 10 cm, 20 cm and 30 cm soil depths in harvester and forwarder operations and also to estimate the degree of soil surface disturbance. The results indicated that soil bulk density in the non-slash treatment site increased 10 %~29 % (25~139 % in soil penetration resistance) at all soil depths, compared with the slash treatment site(slash $11.5kg/m^2$). Therefore, the creation of a slash mat could be an effective way to minimize the changes of soil physical properties. In addition, 92 % of total soil compaction in slash treatment site was created within harvester 1 pass and forwarder 5 passes. In non-slash treatment site, 84 % of total soil compaction was created within first harvester and forwarder passes. The results showed that slash treatment was effective to reduce soil compaction caused by machine passes and also it is necessary to create designed forwarding trails for minimizing soil compaction area at timber harvesting sites.

Evaluation of Spatial Dose Rate in Working Environment during Non-Destructive Testing using Radioactive Isotopes (방사성동위원소를 이용한 비파괴 검사 시 작업환경 내 공간선량률 평가)

  • Cho, Yong-In;Kim, Jung-Hoon;Bae, Sang-Il
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.373-379
    • /
    • 2022
  • The radiation source used for non-destructive testing have permeability and cause a scattered radiation through collisions of surrounding materials, which causes changes in the surrounding spatial dose. Therefore, this study attempted to evaluate and analyze the distribution of spatial dose by source in the working environment during the non-destructive test using monte carlo simulation. In this study, Using FLUKA, a simulation code, simulates 60Co, 192Ir, and 75Se source used in non-destructive testing, The reliability of the source term was secured by comparing the calculated dose rate with the data of the Health and Physics Association. After that, a non-destructive test in the radiation safety facility(RT-room) was designed to evaluate the spatial dose according to the distance from the source. As a result of the spatial dose evaluation, 75Se source showed the lowest dose distribution in the frontal position and 60Co source showed a dose rate of about 15 times higher than that of 75Se and about 2 times higher than that of 192Ir. In addition, the spatial dose according to the distance tends to decrease according to the distance inverse square law as the distance from the source increases. Exceptionally, 60Co, 192Ir, and 75Se sources confirmed a slight increase within 2 m of position. Based on the results of this study, it is believed that it will be used as supplementary data for safety management of workers in radiation safety facilities during non-destructive testing using radioactive isotopes.

무령왕릉보존에 있어서의 지질공학적 고찰

  • 서만철;최석원;구민호
    • Proceedings of the KSEEG Conference
    • /
    • 2001.05b
    • /
    • pp.42-63
    • /
    • 2001
  • The detail survey on the Songsanri tomb site including the Muryong royal tomb was carried out during the period from May 1 , 1996 to April 30, 1997. A quantitative analysis was tried to find changes of tomb itself since the excavation. Main subjects of the survey are to find out the cause of infiltration of rain water and groundwater into the tomb and the tomb site, monitoring of the movement of tomb structure and safety, removal method of the algae inside the tomb, and air controlling system to solve high humidity condition and dew inside the tomb. For these purposes, detail survery inside and outside the tombs using a electronic distance meter and small airplane, monitoring of temperature and humidity, geophysical exploration including electrical resistivity, geomagnetic, gravity and georadar methods, drilling, measurement of physical and chemical properties of drill core and measurement of groundwater permeability were conducted. We found that the center of the subsurface tomb and the center of soil mound on ground are different 4.5 meter and 5 meter for the 5th tomb and 7th tomb, respectively. The fact has caused unequal stress on the tomb structure. In the 7th tomb (the Muryong royal tomb), 435 bricks were broken out of 6025 bricks in 1972, but 1072 bricks are broken in 1996. The break rate has been increased about 250% for just 24 years. The break rate increased about 290% in the 6th tomb. The situation in 1996 is the result for just 24 years while the situation in 1972 was the result for about 1450 years. Status of breaking of bircks represents that a severe problem is undergoing. The eastern wall of the Muryong royal tomb is moving toward inside the tomb with the rate of 2.95 mm/myr in rainy season and 1.52 mm/myr in dry season. The frontal wall shows biggest movement in the 7th tomb having a rate of 2.05 mm/myr toward the passage way. The 6th tomb shows biggest movement among the three tombs having the rate of 7.44mm/myr and 3.61mm/myr toward east for the high break rate of bricks in the 6th tomb. Georadar section of the shallow soil layer represents several faults in the top soil layer of the 5th tomb and 7th tomb. Raninwater flew through faults tnto the tomb and nearby ground and high water content in nearby ground resulted in low resistance and high humidity inside tombs. High humidity inside tomb made a good condition for algae living with high temperature and moderate light source. The 6th tomb is most severe situation and the 7th tomb is the second in terms of algae living. Artificial change of the tomb environment since the excavation, infiltration of rain water and groundwater into the tombsite and bad drainage system had resulted in dangerous status for the tomb structure. Main cause for many problems including breaking of bricks, movement of tomb walls and algae living is infiltration of rainwater and groundwater into the tomb site. Therefore, protection of the tomb site from high water content should be carried out at first. Waterproofing method includes a cover system over the tomvsith using geotextile, clay layer and geomembrane and a deep trench which is 2 meter down to the base of the 5th tomb at the north of the tomv site. Decrease and balancing of soil weight above the tomb are also needed for the sfety of tomb structures. For the algae living inside tombs, we recommend to spray K101 which developed in this study on the surface of wall and then, exposure to ultraviolet light sources for 24 hours. Air controlling system should be changed to a constant temperature and humidity system for the 6th tomb and the 7th tomb. It seems to much better to place the system at frontal room and to ciculate cold air inside tombs to solve dew problem. Above mentioned preservation methods are suggested to give least changes to tomb site and to solve the most fundmental problems. Repairing should be planned in order and some special cares are needed for the safety of tombs in reparing work. Finally, a monitoring system measuring tilting of tomb walls, water content, groundwater level, temperature and humidity is required to monitor and to evaluate the repairing work.

  • PDF