• Title/Summary/Keyword: 문종

Search Result 1,240, Processing Time 0.026 seconds

Effects of Local Cooling and Root Pruning on Budding and Local Heating on Heating Energy Consumption in Forcing Cultivation of Strawberry (딸기 촉성재배 시 국소 냉방 및 단근처리와 국소난방이 화방출뢰와 난방에너지소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Suk Won;Paek, Yee;Moon, Jong Pil;Jang, Jae Kyung;Oh, Sung Sik
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.46-54
    • /
    • 2019
  • Experiments of local cooling and heating on crown and root zone of forcing cultivation of strawberry 'Seolhyang' using heat pump and root pruning before planting were conducted. During the daytime, the crown surface temperature of the crown local cooling treatment was maintained at $18{\sim}22^{\circ}C$. This is suitable for flower differentiation, while those of control and root zone local cooling treatment were above $30^{\circ}C$. Budding rate of first flower clusters and initial yields were in the order of crown local cooling, root zone local cooling and control in root pruning plantlet and non pruning plantlet, except for purchase plantlet. Those of root pruning plantlet were higher than those of non pruning plantlet. These trends were evident in the yield of the first flower cluster until February 14, 2018, and the effect of local cooling and root pruning decreased from March 9, 2018. The budding rates of the second flower cluster according to the local cooling and root pruning treatments were not noticeable compared to first flower cluster but showed the same tendency as that of first flower cluster. In the heating experiment, root zone local heating(root zone $20^{\circ}C$+inside greenhouse $5^{\circ}C$) and crown local heating(crown $20^{\circ}C$+inside greenhouse $5^{\circ}C$) saved 59% and 65% of heating fuel, respectively, compared to control(inside greenhouse $9^{\circ}C$). Considering the electric power consumption according to the heat pump operation, the heating costs were reduced by 55% and 61%, respectively.

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

Protective effect of matcha green tea (Camellia sinensis) extract on high glucose- and oleic acid-induced hepatic inflammatory effect (고당 및 올레산으로 유도된 간세포에서의 염증반응에 대한 말차(Camellia sinensis) 추출물의 보호효과)

  • Kim, Jong Min;Lee, Uk;Kang, Jin Yong;Park, Seon Kyeong;Shin, Eun Jin;Moon, Jong Hyun;Kim, Min Ji;Lee, Hyo Lim;Kim, Gil Han;Jeong, Hye Rin;Park, Hyo Won;Kim, Jong Cheol;Heo, Ho Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.3
    • /
    • pp.267-277
    • /
    • 2021
  • To evaluate hepatoprotective effects, the antioxidant capacities of matcha green tea extract (Camellia sinenesis) were compared to those of green leaf tea and the anti-inflammatory activities in HepG2 cells were investigated. Evaluation of the total phenolic and total flavonoid content, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity, and inhibitory effect on lipid peroxidation indicated that the aqueous extract of matcha green tea presented significant catechin content and antioxidant capacity compared to those of green leaf tea. In addition, the extract had considerable inhibitory effects on α-glucosidase, α-amylase, and advanced glycation end-products. The matcha green tea extract significantly increased cell viability and reduced reactive oxygen species in H2O2- and high-glucose-treated HepG2 cells. Furthermore, in response to oleic acid-induced HepG2 cell injury, treatment with matcha green tea aqueous extract inhibited lipid accumulation and regulated the expression of inflammatory proteins such as p-JNK, p-Akt, p-GSK-3β, caspase-3, COX-2, iNOS, and TNF-α. Matcha green tea could be used as a functional material to ameliorate hepatic lipid accumulation and inflammation.

Effect of Thermal Method on the Activation of Brown Adipose Tissue (온열 요법이 갈색지방세포 활성화에 미치는 영향)

  • You, Yeon Wook;Lee, Chung Wun;Seon, Ahn Jeong;Lee, Dong Eun;Moon, Jong Wun;Kim, Yun Cheol;Park, So Hyeon;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.48-54
    • /
    • 2021
  • Purpose In 18F-FDG PET/CT, the absorption of 18F-FDG due to the activation of Brown Adipose Tissue (BAT) greatly interferes with the discrimination of lymph node malignant metastasis. Warming the patient's body temperature before and after injection of 18F-FDG to prevent FDG absorption by BAT is a safe and non-pharmacological approach. The purpose of this study was to identify and select patients with a high potential for BAT activation in advance, and to investigate whether BAT can inhibit FDG absorption when the body temperature is raised for a short time by directly applying heat to the target patient. Materials and Methods Among the patients who underwent 18F-FDG PET/CT at the National Cancer Center from January 2020 to December 2020, 825 female patients (415 in the thermal group, 410 in the non-thermal group) under 50 years old were included. The thermal group was administered heat for 10 minutes before injection of 18F-FDG. For statistical analysis, the Z test comparing the ratios between the two groups was used, and logistic regression analysis was performed to correct for important variables (BMI, outdoor temperature, blood sugar) according to the results of the previous retrospective study. Results Among 825 patients, 19 patients with BAT activated (Thermal group: 5(1.2%), Non-thermal group: 14(3.41%)) accounted for 2.3% of the total. As a result of performing the Z test to compare the ratios between the two groups, the activation of BAT in the thermal group was significantly decreased (P=0.034). In the univariate logistic regression analysis, the activation of BAT was also decreased in the thermal group (OR: 0.34, P<0.05). In the multivariate results, BAT activation increased in patients younger than 45 years old (OR: 4.46, P<0.05) and outdoor temperature less than 13.2 degrees (OR: 9.97, P<0.05). BAT activation tended to decrease in the thermal group, but there was no significant difference (OR: 0.37, P=0.066). Conclusion We confirmed that the activation of BAT tends to decrease by 62.5% in the group subjected to the thermal method, and it will be of great help in preventing FDG absorption of BAT more effectively in the future.

A study on the significance and structural improvement of the stone chamber tomb by the application of a compound lime - Mortar during the reign of king Sejong in the Joseon Dynasty (조선 세종대 삼물회(三物灰) 도입에 따른 석실릉 구조개선과 의의)

  • SHIN, Jihye
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.223-242
    • /
    • 2022
  • The main purpose of this study is to find out the meaning of structural changes that appeared in the royal tombs of the Joseon Dynasty after the application of a compound lime-mortar(Sammulhoe三物灰: the mortar with lime, sand, ocher). In the early Joseon Dynasty, the royal tomb was constructed by following the system of the stone chamber tomb in the Goryeo Dynasty. However the system of the stone chamber tomb recorded in 『GukJo-OReYi(國朝五禮儀: The five category's formalities in the Joseon Dynasty)』 is very different from that in the Goryeo Dynasty. The biggest difference is that a compound lime-mortar was applied into the system of the stone chamber tomb in order to attempt structural reinforcement. This change reflects King Sejong's willingness to build a dense structure in which water does not permeate the stone chamber when Yeongneung(英陵) was built in 1446(the 28th year of King Sejong's reign). Yeongneung is a complex structure consisting of a stone chamber and compound lime-mortar wall. After constructing a stone chamber, the 1.2m(4尺) thick wall with a compound lime-mortar is additionally constructed outside the stone chamber structure. In 1468(the year of King Yejong's accession), according to the will of King Sejo, the stone chamber system was abolished and the Hyeongung(玄宮: the chamber enshrining a coffin of the deceased king or queen consort) was constructed only by the thick wall with a compound lime-mortar. This change become a primary cause for the royal tomb to be constructed as Hoekyukneung(灰隔陵: the royal tomb with chamber constructed only by the thick wall with compound lime-mortar) in the late Joseon Dynasty. The Hoekyukneung in the late Joseon Dynasty has been constructed with the method of structure and construction for the thick wall with a compound lime-mortar since the complex structure recorded in 『GukJo-OReYi(國朝五禮儀)』. The Hoekuykseoksilneung(灰隔石室陵: the complex structure consisting of a stone chamber and compound lime-mortar wall) is unique tomb style of Joseon Dynasty and become a motive of tomb system(Hoekuykneung) in the late Joseon Dynasty.

Fertilizer Effect of Waste Nutrient Solution in Greenhouses for Young Radish Cultivation (열무 재배를 위한 시설하우스 폐양액의 비료 효과)

  • Hong, Youngsin;Moon, Jongpil;Park, Minjung;Son, Jinkwan;Yun, Sungwook
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.460-467
    • /
    • 2022
  • The purpose of this study is to enhance utilization of the waste nutrient solution (WNS) disposed at the hydroponic greenhouse. Several sets of testing were conducted to examine the effects of WNS: (a) a fertilizer effect, (b) soil column leaching, and (c) crop cultivation. The fertilizer effect test was applied in young radish cultivation by examining the growth characteristics of young radish and soil based on inorganic nitrogen according to the soil treatment of the nitrogen fertilizer (NF) and the WNS. The fertilizer effects and crop cultivation test were conducted with five treatments (A-E): A, non-treatment (water); B, 100% of NF; C, 70% of NF + 30% of WNS; D, 50% of NF + 50% of WNS; and E, 30% of NF + 70% of WNS. The soil column leaching test was conducted with three treatments: non-treatment (water), 100% of NF, 50% of WNS + 50% of NF. As a result, the chemical properties of the WNS were pH 6.0, EC 2.4dS·m-1, total phosphorus (T-P) 28mg·L-1, ammonium nitrogen (NH4-N) 5.0mg·L-1, and nitrate nitrogen (NO3-N) 301mg·L-1. The chemical properties of the soil were pH 5.51, EC 0.31dS/m, organic matter 2.08g·kg-1, NO3-N 9.64mg·kg-1, and NH4-N 3.20mg·kg-1. The results of fertilizer effects showed that the ratio of 50% or less of NF and 50% or more of WNS was high in young radish growth. There was no statistically significant difference between the soil chemistry in the C-E treatments where WNS was mixed with NF and the B treatment where only NF was applied. As a result of the soil column leaching test, there was no significant difference in the concentrations of NO3 and NH4 in the treatment of 100% of NF and 50% of NF + 50% of WNS. The study indicates, if the mixed fertilizer of WNS and NF is applied in the soil cultivation of young radish, it will reduce the use of NF and environmental pollution. This also helps reduce production costs on farmers and increase the yield of young radish.

Photosynthesis by Leaf Age and Fruit Characteristics by Fruiting Nodes in Vertical and Hydroponic Cultivation of Oriental Melon Applied with Air Duct for High-temperature Season (고온기 송풍 덕트 적용 수직·수경재배 참외의 엽령별 광합성과 착과 절위별 과실 특성)

  • Youngsin Hong;Sohyun Park;Sungwook Yun;Jinkyung Kwon;Siyoung Lee;Sanggyu Lee;Jongpil Moon;Jaekyung Jang;Hyojun Bae;Jeongsu Hwang
    • Journal of Bio-Environment Control
    • /
    • v.32 no.2
    • /
    • pp.89-96
    • /
    • 2023
  • This study was conducted to apply with an air duct for the cooling and a utilizing cultivating method that uses the fruiting node and the defoliation to the high-temperature vertical and hydroponic cultivation of the oriental melon. The lower fruiting node (LF) was to remove all third vines generated from 5 nodes of a secondary vine. The higher fruiting node (HF) was fruiting on the third vine generated from a first node of the third vine. The direction of the stem string; upward (UW), downward (DW). Four treatment conditions were applied with the LF-UW, LF-DW, HF-UW (control), and HF-DW. The leaf age of melon leaves was measured for photosynthesis at 3 days intervals, and the fruit characteristic was conducted on 79 fruits in each treatment. The photosynthesis rate steadily increased after leaf development, reaching 20.8 μmol CO2·m-2·s-1 on the 10 days, gradually increasing to 21.3 μmol CO2·m-2·s-1 on the 19 days, and reaching 23.4 μmol CO2·m-2·s-1 on the 32 days. After that, it lowered to 16.8 μmol CO2·m-2·s-1 on the 38 days and dropped significantly to 7.6 μmol CO2·m-2·s-1 on the 47 days. As a result of the fruit characteristics by fruiting nodes, the treatments of the fruit length was 12.6-13.4 cm, respectively, which was significant, and the fruit width was 7.9- 8.6 cm, respectively, was not significant. The soluble content ranged from 12.9 to 15.7°Brix, and the significance of all treatments, and higher than of LF-DW and HF-UW. The photosynthesis rate of melon leaves was good until 32 days after leaf development, but after that, the rate decreased. As for fruit quality, it was conformed that melons can be cultivated at the LF because the fruit enlargement and soluble content dose not decrease even when set at the LF. Results indicated that those can be used for LF and defoliation in the development of vertical and hydroponic cultivation method in high-temperature season.

A Study on the Bapyo Ritual Procedures and Costumes Recorded in the Five rituals of Sejong-Silok (『세종실록(世宗實錄)』, 「오례(五禮)」에 기록된 배표의 절차와 복식 연구)

  • KIM Jinhong;CHO Woohyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.142-160
    • /
    • 2023
  • The position of the people who participated in the Bapyo Ritual held in the reign of King Sejong and the corresponding costumes were examined. The king, who was the executive body of the ritual, wore Myeon-Bok, a court dress, and Myeon-Bok was Gujang-Bok made of Jang-wha on Guryu-Pyeongcheongwan. Crown princes, royal families, and government officials wore Oryang-Gwan and Jekraeui, which were Jobok. The crown princes' Joboks were changed from Oryang-Gwan to Wukryang-Gwan in the dynasty year 10 of King Sejong, and in the year of King Munjong's accession, Myeon-Bok was received, and after King Danjong, the crown princes wore Palryu-Pyeongcheongwan and Chiljang-Bok. Diplomats and Jongsagwan who were the envoys wore Sangbok. A Sangbok worn by the diplomat was Samo with Danryeong, Seo-Dae, and Hyeopgeum-Hwa, and a Sangbok worn by Jongsagwan was Samo, Danryeong, Heukgak-Dae, and Heukpi-Hwa. Byulgam, who served as an attendant to the king in the king's close quarters, wore Gongbok and Sangbok. Gongbok consisted of Ja-Geon, Danryeong and Heukpi-Hwa, and Sangbok consisted of orange color Cho-Rip, Jikryeong, Joa, and Heukpi-Hwa. The person holding San, Gae , Sujeongjang, and Geumwolbu wore Ja-Geon and Cheong-Ui, and Seon wore Pimoja and Hong-Ui. Siwigun wore armor and helmets equipped with weapons. Among court musicians, Aksa's costumes consisted of Bokdu, Bigongbok, Geumdonghyeokdae, Bibaekdaedae, and Opiri, and Aksaeng's one composed of Gaechaek, Bisuransam, Hyupgo, Mal, Maldae, and Opiri. As a result of the above, the process of ceremonial clothes becoming uniform clothes in the reign of King Sejong was confirmed. The king and lower-ranking officials such as crown princes, government officials, diplomats, Byulgam, armies for ceremonial weaponry, and court musicians participating in the Bapyo Ritual wore the highest grade of ceremonial clothes for each class. King Sejong had repeated discussions to build a nation based on Confucianism, and arranged each rite and corresponding costume, and the Bapyo Ritual costume was also systematically prepared for each position. The ceremonial clothing organized during the reign of King Sejong was regulated in Yejon and became the basis for continuing to the late Joseon Dynasty.

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Conservation Status, Construction Type and Stability Considerations for Fortress Wall in Hongjuupseong (Town Wall) of Hongseong, Korea (홍성 홍주읍성 성벽의 보존상태 및 축성유형과 안정성 고찰)

  • Park, Junhyoung;Lee, Chanhee
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.3
    • /
    • pp.4-31
    • /
    • 2018
  • It is difficult to ascertain exactly when the Hongjuupseong (Town Wall) was first constructed, due to it had undergone several times of repair and maintenance works since it was piled up newly in 1415, when the first year of the reign of King Munjong (the 5th King of the Joseon Dynasty). Parts of its walls were demolished during the Japanese occupation, leaving the wall as it is today. Hongseong region is also susceptible to historical earthquakes for geological reasons. There have been records of earthquakes, such as the ones in 1978 and 1979 having magnitudes of 5.0 and 4.0, respectively, which left part of the walls collapsed. Again, in 2010, heavy rainfall destroyed another part of the wall. The fortress walls of the Hongjuupseong comprise various rocks, types of facing, building methods, and filling materials, according to sections. Moreover, the remaining wall parts were reused in repair works, and characteristics of each period are reflected vertically in the wall. Therefore, based on the vertical distribution of the walls, the Hongjuupseong was divided into type I, type II, and type III, according to building types. The walls consist mainly of coarse-grained granites, but, clearly different types of rocks were used for varying types of walls. The bottom of the wall shows a mixed variety of rocks and natural and split stones, whereas the center is made up mostly of coarse-grained granites. For repairs, pink feldspar granites was used, but it was different from the rock variety utilized for Suguji and Joyangmun Gate. Deterioration types to the wall can be categorized into bulging, protrusion of stones, missing stones at the basement, separation of framework, fissure and fragmentation, basement instability, and structural deformation. Manually and light-wave measurements were used to check the amount and direction of behavior of the fortress walls. A manual measurement revealed the sections that were undergoing structural deformation. Compared with the result of the light-wave measurement, the two monitoring methods proved correlational. As a result, the two measuring methods can be used complementarily for the long-term conservation and management of the wall. Additionally, the measurement system must be maintained, managed, and improved for the stability of the Hongjuupseong. The measurement of Nammunji indicated continuing changes in behavior due to collapse and rainfall. It can be greatly presumed that accumulated changes over the long period reached the threshold due to concentrated rainfall and subsequent behavioral irregularities, leading to the walls' collapse. Based on the findings, suggestions of the six grades of management from 0 to 5 have been made, to manage the Hongjuupseong more effectively. The applied suggested grade system of 501.9 m (61.10%) was assessed to grade 1, 29.5 m (3.77%) to grade 2, 10.4 m (1.33%) to grade 3, 241.2 m (30.80%) and grade 4. The sections with grade 4 concentrated around the west of Honghwamun Gate and the east of the battlement, which must be monitored regularly in preparation for a potential emergency. The six-staged management grade system is cyclical, where after performing repair and maintenance works through a comprehensive stability review, the section returned to grade 0. It is necessary to monitor thoroughly and evaluate grades on a regular basis.