• Title/Summary/Keyword: 무인 영상

Search Result 1,398, Processing Time 0.03 seconds

Oral History as a Record of Dance (무용 기록으로서의 구술사)

  • Lee, Eunjoo
    • Trans-
    • /
    • v.6
    • /
    • pp.43-78
    • /
    • 2019
  • Dance is an art that includes not only art historical facts, but also a series of processes for dancers' body, choreography, and the creation of entire process of dances and their lives. In other words, dance is the art of embodying the experience and consciousness of the dancer as the subject, and embodying it through the physical body, and therefore, the existing empirical study which relies solely on the literature in the history of dance study is difficult to deliver a complete history. Oral history is a new methodology historical writing that overcomes the limitations of research methods based on literature centered documents. Oral history in the field of dance is that the dancer becomes the subject of the history of dance's narrative. The memory and testimony of a dancer can become a history, complement the missing parts of the documentary record, and amount to analysis and interpretation to attempt the history of dance from various perspectives. The history of dance through oral history analysis thus generates another view from the literature. The oral history is acted as a prism that can explore the sociocultural discourse of the time and the history of dance. As a new academic challenge for the history of dance field, I expect to be able to review the artistic, social, and cultural functions and roles of dance beyond the limit of existing literature-oriented history study and to be able to progress to various the history of dance.

  • PDF

Design and Comparison of Superconducting Magnets with Circular Coil Elements for Magnetic Resonance Imaging (원형무코일로 구성된 MRI용 초전도 자석의 설계와 비교)

  • Kim, Yong-Gwon;Hyun, Jung-Ho;Seo, Jeung-Hoon;Kim, Hyug-Gi;Oh, Chang-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.6
    • /
    • pp.57-62
    • /
    • 2011
  • This paper proposed a method which is the three types of magnet model for improving field inhomogeneity of superconducting magnet. The length of coil wire was compared for the optimized current pattern using minimum power methods and field inhomogeneity under the specific simulation condition in case of same magnet field strength about each magnet type field inhomogeneity. Length of wire and field inhomogeneity were compared under the same condition(18 target points, 20cm DSV). According to the simulation results, the smaller target points can reduce the wire length but it can not improve the field inhomogeneity. Length of wire and low field inhomogeneity can not improve in same time. However, small DSV and reducing target points can overcome the these problem. And to conclude, if it processes shimming as reducing target points in case of magnet model which is open to space, about the size of same imaging region it needs a lot of current values(or the length of wire) and decreases field homogeneity but it is useful to get small ROI.

Control of Paprika Powdery Mildew Using Cooking Oil and Yolk Mixture (난황유를 이용한 파프리카 흰가루병 방제)

  • Lee, Jung-Han;Han, Ki-Soo;Kwon, Young-Sang;Kim, Dong-Kil;Kim, Hee-Kyu
    • Research in Plant Disease
    • /
    • v.14 no.2
    • /
    • pp.112-116
    • /
    • 2008
  • Powdery mildew of Paprika caused by Leveillula taurica has been a serious problem in greenhouse. It is an unusual endophytic powdery mildew because the mycelia grow inside the leaf, such that the pale yellow lesions on adaxial surfaces appear first and the white powdery lesion/signs develop later on the corresponding to the spots of the abaxial leaf surface, where the conidiophores are typically emerge through the stomatal opening. Although one foliar application of cooking oil and yolk mixture(COY) to the foliage was not practically effective enough, two or three, weekly application of COY to the foliage at either 0.3 or 0.5% concentration resulted in excellent control against powdery mildew with disease index less/lower than 1, respectively. This treatment could provide protection for three weeks, which, we believe, is not only cost-effective, but also environment-friendly. Powdery mildew fungus was affected by COY treatment quickly which is recognizable in three days. Net photosynthesis and evapotranspiration was remarkably reduced by powdery mildew infection compared to healthy leaves, suggesting that prevention and early protection is the most critical strategy for peak paprika fruit yield. Moreover, COY treatment did not adversely affect the photosynthesis and evapotranspiration of foliages.

Design requirements of mediating device for total physical response - A protocol analysis of preschool children's behavioral patterns (체감형 학습을 위한 매개 디바이스의 디자인 요구사항 - 프로토콜 분석법을 통한 미취학 아동의 행동 패턴 분석)

  • Kim, Yun-Kyung;Kim, Hyun-Jeong;Kim, Myung-Suk
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.103-110
    • /
    • 2010
  • TPR(Total Physical Response) is a new representative learning method for children's education. Today's approach to TPR has focused on signals from a user which becomes input data in a human-computer interaction, but the accuracy of sensing from body signals(e. g. motion and voice) isn't so perfect that it seems difficult to apply on an education system. To overcome these limits, we suggest a mediating interface device which can detect the user's motion using correct numerical values such as acceleration and angular speed. In addition, we suggest new design requirements for the mediating device through analyzing children's behavior as human factors by ethnography research and protocol analysis. As a result, we found that; children are unskilled in physical control when they use objects; tend to lean on an object unconsciously with touch. Also their behaviors are restricted, when they use objects. Therefore a mediating device should satisfy new design requirements which are make up for unskilled handling, support familiar and natural physical activity.

  • PDF

Acceleration of Wound Healing and Collagen Deposition in Rat Skin by High Voltage Pulsed Current Stimulation (고전압맥동전류자극이 흰쥐 피부 창상치유와 교원질 축적에 미치는 효과)

  • Lee Jae-hyoung;Song In-young;Kim Jong-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.4
    • /
    • pp.1-12
    • /
    • 2003
  • The purpose of this study was to investigate the effect of high voltage pulsed current stimulation (HVPCS) on the healing rate of a dermal wound in a rat. We also determined the mechanism of promoting healing by HVPCS. Twenty male Sprague-Dawley rats were randomly divided into two group; HVPCS group (n=10) and control group (n=10). The HVPCS rats received electrical stimulation with a current intensity of 50 V at 100 pps for a duration of 30 minutes, while the control group was given the same treatment without electricity for a week. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with Masson's trichrome, hematoxylin and eosin (H&E). The fibroblasts and collagen density were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A Student t-test showed a significantly higher wound healing rate of the HVPCS group than control (t=-4.161, p<0.001). The fibroblasts in the HVPCS group were higher than in the control group (t=-4.921, p<0.001). The density of collagen in the HVPCS group was also higher than in the control group (t=-4.367, p<0.001). These results indicate that the HVPCS accelerated the rate of healing in dermal wound, and increased fibroblasts and collagen density in the regenerative dermis. These findings suggest that the HVPCS may activate fibroblasts by alteration of the electrical environment, and it may increase collagen synthesis in the regenerative dermal wound.

  • PDF

Fingerprint Recognition Algorithm using Clique (클릭 구조를 이용한 지문 인식 알고리즘)

  • Ahn, Do-Sung;Kim, Hak-Il
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.2
    • /
    • pp.69-80
    • /
    • 1999
  • Recently, social requirements of personal identification techniques are rapidly expanding in a number of new application ares. Especially fingerprint recognition is the most important technology. Fingerprint recognition technologies are well established, proven, cost and legally accepted. Therefore, it has more spot lighted among the any other biometrics technologies. In this paper we propose a new on-line fingerprint recognition algorithm for non-inked type live scanner to fit their increasing of security level under the computing environment. Fingerprint recognition system consists of two distinct structural blocks: feature extraction and feature matching. The main topic in this paper focuses on the feature matching using the fingerprint minutiae (ridge ending and bifurcation). Minutiae matching is composed in the alignment stage and matching stage. Success of optimizing the alignment stage is the key of real-time (on-line) fingerprint recognition. Proposed alignment algorithm using clique shows the strength in the search space optimization and partially incomplete image. We make our own database to get the generality. Using the traditional statistical discriminant analysis, 0.05% false acceptance rate (FAR) at 8.83% false rejection rate (FRR) in 1.55 second average matching speed on a Pentium system have been achieved. This makes it possible to construct high performance fingerprint recognition system.

  • PDF

A prospective clinical trial to compare the performance of four initial orthodontic archwires (교정치료 초기에 사용되는 4가지 호선의 초기 치료효과를 비교하기 위한 전향적 임상 실험 연구)

  • Quintao, Catia C. A.;Jones, Malcoim L.;Menezes, Luciane M.;Koo, Daniel;Elias, Carlos N.
    • The korean journal of orthodontics
    • /
    • v.35 no.5 s.112
    • /
    • pp.381-387
    • /
    • 2005
  • The aim of this study was to compare the clinical performance of 4 types of orthodontic wires, indicated for initial tooth alignment: stainless steel, multistranded steel, superelastic and thermoactivated nickel-titanium. A prospective randomized clinical trial was conducted on a sample of 45 patients, at the Dental School of the State University of Rio do Janeiro, Brazil. Fixed appliances were fitted and study casts were obtained from each patient. Randomly, the wires were allocated as follows: 26 dental arches for superelastic NiTi wires, 22 for stainless steel, 22 for multistranded and 20 for thermoactivated archwires. After 8 weeks, the archwires were removed and impressions for study casts were taken again. Using a 3D digitization technique of defined anatomical points on the study cast crowns, a Dental Irregularity Index (DII) was created for each study cast. The difference between DII before and after the archwire insertion expressed the aligning effect of the wires. ANOVA tests were employed to evaluate the anatomical point approximation (positive DII) and separation (negative DII), for each area of the dental arches: upper and lower whole arch and anterior arch. Results showed no significant difference between the different archwires.

Change of Contrast Sensitivity in Peripheral Vision Following Eccentric Viewing Training (중심외주시 훈련 후 주변시야에서의 대비감도 변화)

  • Seo, Jae-Myoung;Lee, Ki-Young;Lim, Yong-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.99-104
    • /
    • 2014
  • Purpose: This study was to investigate the functional improvement in peripheral vision following eccentric viewing training. Methods: 14 subjects with normal vision took a part with their right eye, peripheral retinal which is $20^{\circ}$ lateral area from the fovea was examined for contrast sensitivity(CS). Eccentric viewing training was performed for 21days with an hour image viewing and examination was repeated. Results: The critical durations for 0.7 cpd were increased 2.67(467 ms) for pre-eccentric viewing training to 2.79(616 ms) for post-eccentric viewing training (p>0.05). The critical durations for 3.0 cpd were also increased 2.53(341 ms) for pre-eccentric viewing training to 3.04(1102 ms) for post-eccentric viewing training (p>0.05). Conclusions: It is recommended to use higher spatial frequency with higher CS for eccentric viewing training and to train more frequently for a short time. Moreover, the study on Korean standardizing of the visual rehabilitation for low vision based on the etiology is sorely required.

Production of the Recombinant Single Chain Anti-B Cell Lymphoma Antibody and Evaluation of Immunoreactivity (pET vector를 통한 유전자 재조합 단일사슬 항 B형 림프종 항체의 생산과 면역반응성 평가)

  • Jung, Jae-Ho;Choi, Tae-Hyun;Woo, Kang-Sun;Chung, Wee-Sup;Kim, Soo-Gwan;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.211-217
    • /
    • 2006
  • Purpose: Recombinant ScFv lym-1 was produced, using pET vector system for large scale production. Methods: ScFv lym-1 gene inserted pET-22b (+) vector, was expressed in E.coli BL-21 strain. ScFv lym-1 antibody extracted from periplasm, was purified with His-Taq column. To evaluated immunoreactivity with Raji cell, ScFv lym-1 was labeled with I-125 and I-125 ScFv lym-1 was purified with desalting column. Raji cell was injected into the C57BR/cdJ SCID mice. Gamma camera imaging were taken time point at 1, 8, 24, and 48 hr with 8 mm pinhole collimator. Results: An active scFv lym-1 could be produced in E. coli with soluble iron using PET vector system. Immuuoreaetivity and affinity constant of IgG lym-1 were 54% and $1.83{\times}10^9M^{-1}$, respectively, and those of scFv lym-1 were 53.7% and $1.46{\times}10^9M^{-1}$, respectively. Biodistribution of I-125 scFv lym-1 antibody showed faster clearance in blood, spleen, kidney and than I-125 IgG lym-1 antibody. Gamma camera image of I-125 scFv lym-1 antibody showed faster clearance and tumor targeting liver than I-125 IgG lym-1 antibody. Conclusions: In vitro properties of scFv lym-1 were similar to those of IgG lym-1. ScFv lym-1 showed faster blood clearance than IgG lym-1 There results suggest that scFv lym-1 antibody can be useful for tumor imaging agent.

Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated Tc-99m-MIBI Myocardial SPECT (게이트 Tc-99m-MIBI SPECT에서 국소 심근운동과 수축기 심근두꺼워짐 자동정량화법의 재현성)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Cheon, Gi-Jeong;Kim, Yu-Kyeong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.487-496
    • /
    • 2000
  • Purpose: The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Materials and Methods: Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction $51{\pm}14%$) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using $AutoQUANT^{TM}$ software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Results: Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Conclusion: Segmental wall motion and systolic thickening quantified using $AutoeUANT^{TM}$ software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening.

  • PDF