• Title/Summary/Keyword: 무릎 인공관절

Search Result 33, Processing Time 0.022 seconds

The Effect of Cultured Perichondrial Cell Sheet Covered Highly Active Engineered Cartilage: in vivo Comparative Assessment (배양연골막이 피복된 고효능 인공연골의 생체내 효과)

  • Park, Se-Il;Moon, Young-Mi;Jeong, Jae-Ho;Jang, Kwang-Ho;Ahn, Myun-Hwan
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.486-496
    • /
    • 2011
  • A special mesenchymal tissue layer called perichondrium has a chondrogenic capacity and is a candidate tissue for engineering of cartilage. To overcome limited potential for chondrocyte proliferation and re-absorption, we studied a method of cartilage tissue engineering comprising chondrocyte-hydrogel pluronic complex (CPC) and cultured perichondrial cell sheet (cPCs) which entirely cover CPC. For effective cartilage regeneration, cell-sheet engineering technique of high-density culture was used for fabrication of cPCs. Hydrogel pluronic as a biomimetic cell carrier used for stable and maintains the chondrocytes. The human cPCs was cultured as a single layer and entirely covered CPC. The tissue engineered constructs were implanted into the dorsal subcutaneous tissue pocket on nude mice (n = 6). CPC without cPCs were used as a controls (N = 6). Engineered cartilage specimens were harvested at 12 weeks after implantation and evaluated with gross morphology and histological examination. Biological analysis was also performed for glycosaminoglycan (GAG) and type II collagen. Indeed, we performed additional in vivo studies of cartilage regeneration using canine large fullthickness chondrial defect model. The dogs were allocated to the experimental groups as treated chondrocyte sheets with perichondrial cell sheet group (n = 4), and chondrocyte sheets only group (n = 4). The histological and biochemical studies performed 12 weeks later as same manners as nude mouse but additional immunofluorescence study. Grossly, the size of cartilage specimen of cPCs covered group was larger than that of the control. On histological examination, the specimen of cPCs covered group showed typical characteristics of cartilage tissue. The contents of GAG and type II collagen were higher in cPCs covered group than that of the control. These studies demonstrated the potential of such CPC/cPCs constructs to support chondrogenesis in vivo. In conclusion, the method of cartilage tissue engineering using cPCs supposed to be an effective method with higher cartilage tissue gain. We suggest a new method of cartilage tissue engineering using cultured perichondrial cell sheet as a promising strategy for cartilage tissue reconstruction.

A Numerical Study on the Response of the Tibial Component in Total Knee Arthroplasty to Longitudinal Impact (인공무릎관절 전치환술에 있어 축방향 충격에 의한 Tibial Component의 응답 특성 분석 연구)

  • 조용균;조철형;최재봉;이태수;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.5
    • /
    • pp.503-511
    • /
    • 1998
  • In this study, the stress distribution for different tibial components was observed In order to Investigate the load transfer and potential failure mechanism of the tibial components subjected to dynamic impact loading and also to evacuate the effect of bone-implant bonding conditions on the implant system. The 3-dimensional finite element models included an intact tibia, cemented metal-backed tibial component, uncemented metal-blocked tibial component, cemented all-polyethylene tibial component, and metal-backed component with a debonded bone/stem interface. The results showed that the cemented metal-hocked component Induced slightly higher peak stress at stem tip than the uncemented component. The peak stress of the all-polyethylene tibia1 component at stem trip showed about half thats of metal-backed tibial components. The all-polyethylene component showed a similar dynamic response to intact tibia. In case of debonded bone/stem interface, the peak stress below the metal tray was three times Higher than that of the fully bonded interface and unstable stress distribution at the stem tip was observed with time, which causes another adverse bone apposition and implant loosening. Thus, the all-polyethylene tibial component bonded fully to the surrounding bone might be most desirable system under an impact loading.

  • PDF

A Biomechanical Comparative Analysis of the Multi-Radius Total Knee Arthroplastry System for Go up Stair and Go down Stair (계단 오르기와 내리기 동안 다축범위(multi-radius) 무릎인공관절 수술자의 운동역학적 비교분석)

  • Jin, Young-Wan;Yoo, Byung-In;Kawk, Yi-Sub
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.31-41
    • /
    • 2006
  • The primary purpose of a TKA is to restore normal knee function Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from climbing stairs; (b) provide adequate knee joint stability. A 16-channel MyoResearch XP EMG system was used to collect the differential input surface electromyography signals VM, VL, RF, BF, ST during climbing/descending stair tests. A Peak Motion Measurement System was used to collect the kinematic and kinetic data. AKIN-COM Ill isokinetic dynamometer was used for EMG of VM, VL, RF, BF and ST during maximal voluntary contraction. I Quadriceps EMG results for the VM of the passed 1year group limb demonstrated significant less RMS EMG than that of the passed 3year group limb $60^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The VL of the passed 1year group limb also demonstrated significants less RMS EMG than that of the passed 3year group limb from $60^{\circ}-45^{\circ}$ of knee flexion(p<0.05). Similar to the VM and VL, the RF of the passed 1year group limb showed less RMS EMG than that of the passed 3year group limb from $60^{\circ}-30^{\circ}$ do knee flexion(p<0.05). Hamstring EMG results for the BF of the passed 1year group limb demonstrated less RMS EMG than that of the passed 3year group limb from $75^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The passed 1year group limb tended to have less ADD displacement(p<0.071) than that of the passed 3year group limb. There was no significant difference of the ABD displacement between the passed 1year group and the passed 3year group limbs(p<0.73). The passed 3year group used compensatory adaptation movement strategies to compensate for the strength deficit of passed 3year group limbs. The passed 3year group limb also increased the quadriceps muscle activation level to produce more knee extension moment to compensate for the short quadriceps moment arm. The passe 3year group limb might have an unstable knee joint in the medio-Iateral direction during the climbing/descending by showing a tendency of more ADD displacement and greater hamming co-activation EMG than the passed 1year group limbs. The TKA design was not able to help the knee joint to produce adequate knee extension moment with less quadriceps muscle effort. I think that old man needs continuous exercise for muscle strength.