• Title/Summary/Keyword: 모형 부착

Search Result 300, Processing Time 0.026 seconds

The Dental Hygienists' Perception of the National Practical Examination (치과위생사의 국가 실기시험에 대한 인식)

  • Ko, Da-Kyung;Bae, Sung-Suk
    • Journal of dental hygiene science
    • /
    • v.16 no.6
    • /
    • pp.488-494
    • /
    • 2016
  • The purpose of the present study was to examine dental hygienists' perception of the current national practical examination. This research was performed using 199 self-reported surveys answered by professors of dental hygiene studies and clinical dental hygienist. Frequency analysis, chi-square tests, and analysis of variance were performed by using IBM SPSS Statistics ver. 20.0. The results revealed that many of the respondents consider the current national practical examination to be neutral. They did not think that the current national practical examination questions are useful for assessing occupation-centric integrated clinical practice ability and counseling techniques for patient intervention. The professors of dental hygiene studies believed that among the research tasks required as mentioned in the national practical examination questions, dental polishing and tooth brushing education are of paramount importance, whereas clinical dental hygienists believed that ultrasonic scaling is the most important (p<0.05). Most of the professors of dental hygiene studies reported that they conducted skills education for dental polishing and tooth brushing education, while most of the clinical dental hygienists reported that tasks actually performed in the clinic included impression taking, model fabrication, ultrasonic scaling, and explaining treatment precautions (p<0.05). Therefore, these tasks can be effectively carried out with the improvement of the national dental hygienist practical examination.

A Study on the Shape and Movement in Dissolved Air Flotation for the Algae Removal (수중조류제거(水中藻類除去)를 위한 가압부상(加壓浮上)에 있어서 기포(氣泡)의 양태(模態)에 관한 연구(研究))

  • Kim, Hwan Gi;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.79-93
    • /
    • 1984
  • The dissolved air flotation(DAF) has been shown to be efficient process for the removal of algae ftom water. The efficiency of DAF can be affected by the volume ratio of pressurized liquid to sample, the pressure pressurized liquid, the contact time, the appropriate coagulant and its amount, the water temperature, the turbulence of reactor, the bubble size and rising velocity etc. The purpose of this paper is to compare the practical bubble rising velocity with the theoretical one, to investigate the adhesion phenomenon of bubbles and floc, and the influence of bubble size and velocity upon the process. The results through theoretical review and experimental investigation are as follows: Ives' equation is more suitable than Stokes' equation in computation of the bubble rising velocity. The collection of bubble and algae floc is convective collection type and resulted from absorption than adhesion or collision. The treatment efficiency is excellent when the bubble sizes are smaller than $l00{\mu}m$, and the turbulence of reactor is small. In the optimum condition of continuous type DAF the volume ratio of pressurized liquid to sample is 15%, the contact time in reactor is 15 minutes, the pressure of pressurized liquid is $4kg/cm^2$ and the distance from jet needle to inlet is 30cm.

  • PDF

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON DURING DISTAL EN MASSE MOVEMENT OF THE MAXILLARY DENTITION (상악 치열의 치군 후방이동에 관한 3 차원 유한요소법적 연구)

  • Shin, Soo-Jung;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.563-580
    • /
    • 1998
  • This study was designed to analysis the displacement and stress distribution of individual tooth by orthodontic force during distal on masse movement of the maxillary dentition. In this study, three dimensional finite element analysis was used. Author made the finite element model of maxillary teeth, periodontal ligament, alveolar bone and bracket with anatomic and physiologic characteristics on computer. Author analysed and evaluated the displacement and stress distribution of individual tooth when extraoral force, Class II intermaxillary elastics, ideal arch wire, MEAW and tip back bend were used for distal on masse movement of the maxillary dentition. These analyses were also applied in the case of the maxillary second molar were not extracted. Author compared the results of the cases which maxillary second molar were extracted or not. The results were expressed quantitatively and visually. Author obtained following results, 1. When anterior headgear was applied, the posterior translation, posterior tipping, and vertical displacement of teeth were produced more in the anterior segment of the dentition. 2. When Class II intermaxillary elastics were applied in the ideal arch wire, the teeth displacement were usually produced in the anterior segment. But when tip back bend were added in the ideal arch wire, the orthodontic force produced by elastics were transmitted to the posterior segment. As increasing the tip back bend, posterior translation and lingual tipping of anterior teeth were decreased, posterior translation and tipping displacement of posterior teeth were increased, and extrusion of anterior teeth by Class II elastics were decreased 3. When MDAW and Class II elastics were applied, the teeth movement were sir flu with the case of ideal arch wire and Class II elastics, but more small and uniform teeth displacement were produced Compared with the ideal arch wire, posterior tipping of the posterior segment were more produced than lingual tipping displacement of the anterior segment. 4. When the maxillary second molar without orthodontic appliance existed, the displacement of maxillary first molar were decreased.

  • PDF

The effect of CR-CO discrepancy on cephalometric measurements in Class III malocclusion patients (골격성 III급 부정교합자에서 중심위 변위가 두부 방사선 계측치에 미치는 영향)

  • Park, Yang-Soo;Kim, Jong-Chul;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.26 no.3
    • /
    • pp.255-265
    • /
    • 1996
  • The purpose of this study was to investigate if there were a significant difference between cephalometric measurements of mandibular position derived from a centric occlusion tracing compared to those of a converted centric relation tracing in the Class III malocclusion. The sample consisted of 25 Class III malocclusion and 25 normal occlusion persons who had no orthodontic treatment. The records included an lateral cephalometrics in centric occlusion, centric relation and centric occlusion bite registration and diagnostic casts mounted on the SAM II articulator in CR. The amount of CR-CO discrepancy of condyle was recorded using a MPI(Mandibular Position Indicator, MPI $200^{(R)}$, Great Lakes Orthodontics, USA). The conversion of the CO cephalogram to CR using the MPI readings was performed on the Conversion work sheet. Measures of mandibular position were chosen for the purpose of this study. The comparison of the difference between CO and CR cephalometric measurements in the normal occlusion and Class III malocclusion group were studied. The results were as follows: 1. In the features of CR-CO discrepancy of the condyle, the condyle was displaced posterior and inferior when the teeth were in centric occlusion. The horizontal component(${\Delta}X$) in Class HI malocclusion group was greater than the vertical component(${\Delta}Z$) and also greater than the horizontal component(${\Delta}X$) in normal occlusion group. There was no statistically significant correlation between MPI measurements and the groups of normal occlusion and Class III malocclusion group. 2. In the comparison of the cephalometric measurements in each group, Normal occlusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity and ODI. Class HI malocclusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity, ODI, SNB, APDI, L1-FP and it had more significance than the normal occlusion group. 3. The Value of cephalometric measurements was significantly different between CO and CR but there were no differences between the groups of normal occlusion and Class III malocclusion. The results of this study suggest that if the discrepancies are greater than the amount of normal displacement from clinically captured centric relation, centric relation should be considered as the starting point for proper diagnosis and treatment planning.

  • PDF

Assessment of climate change impact on aquatic ecology health indices in Han river basin using SWAT and random forest (SWAT 및 random forest를 이용한 기후변화에 따른 한강유역의 수생태계 건강성 지수 영향 평가)

  • Woo, So Young;Jung, Chung Gil;Kim, Jin Uk;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.10
    • /
    • pp.863-874
    • /
    • 2018
  • The purpose of this study is to evaluate the future climate change impact on stream aquatic ecology health of Han River watershed ($34,148km^2$) using SWAT (Soil and Water Assessment Tool) and random forest. The 8 years (2008~2015) spring (April to June) Aquatic ecology Health Indices (AHI) such as Trophic Diatom Index (TDI), Benthic Macroinvertebrate Index (BMI) and Fish Assessment Index (FAI) scored (0~100) and graded (A~E) by NIER (National Institute of Environmental Research) were used. The 8 years NIER indices with the water quality (T-N, $NH_4$, $NO_3$, T-P, $PO_4$) showed that the deviation of AHI score is large when the concentration of water quality is low, and AHI score had negative correlation when the concentration is high. By using random forest, one of the Machine Learning techniques for classification analysis, the classification results for the 3 indices grade showed that all of precision, recall, and f1-score were above 0.81. The future SWAT hydrology and water quality results under HadGEM3-RA RCP 4.5 and 8.5 scenarios of Korea Meteorological Administration (KMA) showed that the future nitrogen-related water quality in watershed average increased up to 43.2% by the baseflow increase effect and the phosphorus-related water quality decreased up to 18.9% by the surface runoff decrease effect. The future FAI and BMI showed a little better Index grade while the future TDI showed a little worse index grade. We can infer that the future TDI is more sensitive to nitrogen-related water quality and the future FAI and BMI are responded to phosphorus-related water quality.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Study on the Tractive Characteristics of the Seed Furrow Opener for No-till Planter (무경운(無耕耘) 파종기용(播種機用) 구체기(溝切器)의 견인특성(牽引特性)에 관(關)한 연구(硏究))

  • La, Woo-Jung
    • Korean Journal of Agricultural Science
    • /
    • v.5 no.2
    • /
    • pp.149-157
    • /
    • 1978
  • This study was carried out to obtain basic data for the type selection of furrow openers for the no-tillage soybean planter trailed by the two-wheel tractor from the standpoint of minimum draft and good performance of furrowing. For this study, two models of furrow opener, hoe and disc type, were tested on the artificial soil stuffed in the moving soil bin. The results obtained were as follows. In the case of disc furrow opener, the drafts were measured according to various diameters of discs under the condition of disc angle $8^{\circ}$ and $16^{\circ}$, working depth 3cm and 6cm, working speed 2.75cm/sec. Minimum draft appeared when the diameter of disc was about 28cm and the drafts increased as the diameter of discs became larger or smaller than this diameter. Specific draft showed almost same tendencies as above but showed the minimum when the diameter was about 30cm. For the purpose of controlling the seeding depth, the relationships between draft and working depths, 3cm and 6cm, were tested. The variations of draft concerning the various working depths showed linear changes and were affected in higher degree by depths than other factors. There were general tendencies at both working depths, 3cm and 6cm, that total draft showed the minimum with the disc diameter of about 28cm and specific draft showed it with the disc diameter of about 30cm regardless of disc angle and working speed. For the purpose of controlling the working width and speed, the relationships among drafts, disc angle and working speed were investigated and there were general tendencies that the draft increased as the angle and speed were increased and the draft was affected more by speed than by angle. To compare the hoe-type with disc-type opener, the specific drafts of hoe openers were compared with those of disc opener of $16^{\circ}$ angle and 30cm diameter. The specific draft of disc-type opener with the diameter of 30cm was $0.35{\sim}0.5kg/cm^2$, while $0.71{\sim}1.02kg/cm^2$ in the case of hoe type with the lift angle of $20^{\circ}$ which is 2 times as much as that of disc type in average value. And the furrows opened by disc openers were cleaner than those opened by hoe openers.

  • PDF

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.