• Title/Summary/Keyword: 모터 RPM

Search Result 149, Processing Time 0.021 seconds

Design and Fabrication for the Development of the Distributed Auto Edging Machine (보급형 자동옥습기 개발을 위한 설계 및 제작)

  • Lee, Young-Il;Kim, Jung-Hee;Park, Jee-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.107-115
    • /
    • 2011
  • Purpose: To design and fabricate the distributed auto edging machine for the development. Methods: We got the necessary data needed in design by using CAD. Based on the these data, we fabricated the trial product for the development of the distributed auto edging machine. Results: The patternless mode could be operated by receiving the eyesize data from the auto lay-outer with the RS232C transmission system and the pattern mode could be operated by setting the pattern on the left side of the machine. The distributed auto edging machine were composed with combinations of many elements; head, auto arm, pattern clamp and grinding wheels. The head part controlled the grinding of ophthalmic lens by operating the vertical and horizontal motors. The wheels part was comprised of glass mode, plastic mode, V-bevel mode and polish mode. The slide in the auto arm was equipped on the below of the patten and the slide could hold up the pattern which was rotated by fixed shaft. The pattern clamp could move the head part to the up and down or right or left way by the manual operation of optometrists. Conclusions: We could succeed in making the trial product by applying it to the development of the distributed auto edging machine which could be used as the patternless mode and pattern mode, selectively. Therefore, it was confidently expected that this product was very helpful for the optometrists to dispense the ophthalmic lens because of its cost-efficiency and convenience.

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

초고속 터보 분자펌프의 자기부상 회전 안정성 연구

  • No, Seung-Guk;Gyeong, Jin-Ho;Park, Yong-Tae;Go, Deuk-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.117-117
    • /
    • 2012
  • 반도체 및 디스플레이 공정등에서 고진공 및 급 배기 환경을 제공하기 위하여 사용되는 터보 분자펌프(Turbomolecular Pump, TMP)는 다층의 회전깃을 갖는 로터를 회전시켜 분자를 배출시키는 방식을 사용하는 진공펌프이다. 또한 최근에는 디스플레이 및 반도체 공정에서 높은 진공도뿐만 아니라, 높은 배기속도를 요구하는 추세에 따라, 터보 펌프와 드래그 펌프부분을 동시에 가지고 있어 상대적으로 작동 진공도 영역이 넓은 복합 분자펌프(Compound Turbomolecular Pump, CMP)의 활용도가 넓어지고 있다. 이러한 분자펌프가 장시간의 고속회전에 적합하고, 베어링에서의 오염을 없앨 수 있는 비접촉 방식인 자기부상 방식이 주로 적용된다. 자기베어링 시스템은 하드웨어와 소프트웨어로 나누어질 수 있는데, 하드웨어는 회전하게 되는 블레이드로터 및 자기베어링 로터, 모터 로터 등이 포함된 축과 고정되어 있는 자기베어링 코어와 코일, 변위센서 등의 펌프 하우징 부분, 또한 이를 제어하기 위한 전력 증폭 시스템 등의 기전적인 요소들이 이루어져 있다. 소프트웨어라 할 수 있는 제어시스템에 있어서 자기베어링이 불안정한 특성을 갖는 개루프계를 갖고 있으므로 안정화를 위한 능동제어 시스템이 필수적이며 진동 제어 등의 기능을 갖도록 적용된다. 따라서 이러한 복합분자펌프의 성능은 이러한 시스템을 구성하는 개별 요소의 성능과 이를 통합한 제어시스템의 성능이 결정한다고 할 수 있다. 본 논문에서는 현재 개발중인 2,500 l/s급의 자기부상형 고진공 복합분자펌프의 시작품에 대하여 고속회전의 안정성에 대한 연구를 수행한 내용을 보고하고 있다. 디지털 제어시스템을 적용한 시작품의 최대 26,000 rpm 까지의 고속회전시의 회전 응답 및 진동 특성을 측정 분석하였으며, 로터의 고유진동수 및 진동 모우드를 분석하였다. 또한 연속 작동시의 발열특성과 각 부분의 온도와 회전 안정성과의 관계를 평가하였다.

  • PDF

Single Phase Switched Reluctance Motor for Vacuum Cleaner (진공청소기용 단상 스위치드 리럭턴스 모터)

  • Lim, Jun-Young;Jung, Yun-Chul;Kim, Sang-Young;Choi, Yong-Won;Kim, Jungn-Chul
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.247-251
    • /
    • 2001
  • Universal motors are mainly used for vacuum cleaner application. There are a lot of researches on SRM that applys home appliance throughout the world. The manufacturing cost of SRM drive makes it hard to expand its application to home appliance. This paper presents Single Phase SRM for the vacuum cleaner that has advantge in cost and performance over conventional universal motor. This paper proposes new power device driving scheme by using SRM switching characteristic. The driving scheme is very simple and inexpensive. Dwell Time Control method is used for the minimum switching loss of power device. The switching frequency of power device is less than 4.5kHz at 45,000rpm. By use of this scheme, power device based on very small switching losses can be used on SRM drive. Also, the biggest problem in single phase SRM is starting, this paper shows a new starting algorithm with two hall sensors, accelerating and running sensors, respectively. Finally, the proposed Single Phase SRM achieves higher efficiency and long life time compared to universal motor. Its life time is more than 1500 hours. Its life time is extended 4 times than that of conventional motor and its suction power is increased $20\%$ at the same volume of conventional universal motor.

  • PDF

An Experimental Study for Construction of Aerodynamic Database of the Commercial Propeller (상용 프로펠러 공력 데이터베이스 구축을 위한 실험적 연구)

  • Shim, HoJoon;Kim, Geon-Hong;Cheon, HyeJin
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.5
    • /
    • pp.60-71
    • /
    • 2021
  • Propeller performance measurement system for commercial propeller was designed and applied to the wind tunnel test for 3 commercial propeller models with diameters of 30 inch. The thrust and torque of the propeller was directly measured by using 6-components balance installed on the rotating axis. The measurement system was validated by using wind tunnel balance calibration equipment. Propeller test stand including measurement and rotating system was validated by using QTP propeller. In the hovering condition, we compared the performance test results and the specifications of the commercial propeller provided by the manufacturer and confirmed that there are differences in the thrust and the torque. We measured the propeller performance with various wind speeds, propeller models and angles of attack and was summarized by thrust coefficients. We confirmed that the trend of the thrust coefficients was different in the low angle of attack and high angle of attack. An aerodynamics database that can be used for future aerodynamic design of an unmanned aerial vehicle was secured.

A Study on the Torque Characteristics Depending on the Elastic Body Materials of a Hexadecagon Shaped Ultrasonic Motor (탄성체 재질 변화에 따른 16각형 초음파모터의 토크 특성 연구)

  • Cheon, Seong-Kyu;Jeong, Seong-Su;Lee, Byung-Ha;Ha, Yong-Woo;Kim, Myong-Ho;Park, Tae-Gone
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.286-291
    • /
    • 2014
  • In this study, novel ultrasonic rotary motor of hexadecagon shape stator was proposed. Stator of the hexadecagon ultrasonic motor was composed of an elastic ring and ceramics. The elastic ring had sixteen sides and sixteen angular points. Eight ceramics were attached on the outer surface of the eight sides of the ring. When rotor of cylindrical shaft was inserted inside of the ring stator, central lines of the sixteen sides of the stator hold the shaft by the slight pressures(frictions). This slight pressure was a preload of the motor and it could be controlled by radius and thickness of the ring. When two sinusoidal voltages which have 90 degree phase difference were applied to each four ceramics, elliptical displacements of inner surface of the ring were obtained. These elliptical displacements of the inner surface rotated the shaft rotor through the frictions. The proposed hexadecagon ultrasonic motor was designed and analyzed by using the finite element method (FEM), depending on materials of the elastic ring. Based on the FEM results, one model of motor which showed maximum displacement at contact points was chosen and fabricated. And characteristics of the motor were compared with simulated results. When the motor was fabricated with these results, EL20ET0.5CT0.5CW2 model showed 115[rpm] speed about input voltage of 60[Vrms] at 65.6[kHz]. And the maximum torque of 6[gfcm] was obtained. From these results, the hexadecagon shaped ultrasonic motor can be used to actuator for optical device which needs detailed position control. Also it can be used to medical and portable device by reducing size and weight.

Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture - (트랙터부착형 타워집재기 개발(I) - 설계 및 제작-)

  • Park, Sang-Jun;Kim, Bo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This study was conducted to develop a mobile tower-yarder with tractor for agriculture and forestry that is the efficient yarder in steep terrains, thinning operation and small scale logging operation. It was designed and manufactured that the power source of tower-yarder is equiped three hydraulic pump connected to PTO of tractor, and three hydraulic pump is used to operate the four motor for drum, the cylinder for clutch of interlocker, the cylinder for tower expanding and the out-rigger cylinder. It was to adopt the running skyline system and the inter-lock function, and to equip the double capstan drum, the storage drum and the clutch for interlock in the development of tower-yarder. It was to develop the tower-yarder which the winch torque of double-capstan drum, the traction force of double-capstan drum, the number of rotation of double-capstan drum and the line speed is $191kg{\cdot}m$, 1,910 kgf, 220.5 rpm and 138.5 m/min, respectively. And it was known that the optimum flange diameter of the main and haulback storage drum is about 360 mm and about 460 mm in order to storage the main line length of 250m and the haulback line length of 450 m. The carriage was made to adopt the running skyline system and to equip the lock function in order to the convenience of chocking and the fall down preventing of tree. It was provided to develop the wire remote controller for the inter-lock function, the convenience of control and the efficiency of yarding. In development process, this tower-yarder was attached the 3-point linkage hitch equipment and the tire wheel for the traction and moving of tower-yarder. Also, it was equipped that the out-rigger and the guy line in order to raise the safety and efficiency of yarding of tower-yarder.

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS (반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석)

  • Hwang, Soo-Youn;Oh, So-Ram;Lee, Yoon;Lim, Sang-Min;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 2009
  • This study aimed to assess the influence of different cross-sectional area on the cyclic fatigue fracture of Ni-Ti rotary files using a fatigue tester incorporating cyclical axial movement. Six brands of Ni-Ti rotary files (ISO 30 size with. 04 taper) of 10 each were tested: Alpha system (KOMET), HeroShaper (MicroMega), K3 (SybronEndo), Mtwo (VDW), NRT (Mani), and ProFile (Dentsply). A fatigue-tester (Denbotix) was designed to allow cyclic tension and compressive stress on the tip of the instrument. Each file was mounted on a torque controlled motor (Aseptico) using a 1:20 reduction contra-angle and was rotated at 300 rpm with a continuous, 6 mm axial oscillating motion inside an artificial steel canal. The canal had a $60^{\circ}$ angle and a 5 mm radius of curvature. Instrument fracture was visually detected and the time until fracture was recorded by a digital stop watch. The data were analyzed statistically. Fractographic analysis of all fractured surfaces was performed to determine the fracture modes using a scanning electron microscope. Cross-sectional area at 3 mm from the tip of 3 unused Ni-Ti instruments for each group was calculated using Image-Pro Plus (Imagej 1.34n, NIH). Results showed that NRT and ProFile had significantly longer time to fracture compared to the other groups (p < .05). The cross-sectional area was not significantly associated with fatigue resistance. Fractographycally, all fractured surfaces demonstrated a combination of ductile and brittle fracture. In conclusion, there was no significant relationship between fatigue resistance and the cross-sectional area of Ni-Ti instruments under experimental conditions.

Determination of Freely Dissolved PAHs in Seawater around the Korean Peninsula Using High Speed Rotation-Type Passive Sampling Device (고속회전식 수동형 채집 장치를 이용한 한반도 주변해역에서의 자유용존상 PAHs 측정)

  • JANG, YU LEE;LEE, HYO JIN;JEONG, HAEJIN;JEONG, DA YEONG;KIM, NA YEONG;KIM, GI BEUM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.1
    • /
    • pp.37-48
    • /
    • 2021
  • A new high speed rotation type-passive sampling device (HSR-PSD), which can rotate seawater at high speed and absorb easily and quickly the freely dissolved hydrophobic organic contaminants from seawater, was developed and then applied around the Korean Peninsula. Freely dissolved concentrations (Cfree) of polycyclic aromatic hydrocarbons (PAHs) were determined using the HSR-PSD with low density polyethylene (LDPE) sheets as a passive sampler. Furthermore, dissolved concentrations (Cdissolved) of PAHs in seawater were also obtained from high volume water sampling as a conventional method to account for actual bioavailability. When the LDPE sheets were rotated in the HSR-PSD at 900 rpm, PAHs with log KOW 3.4 ~ 5.2 were equilibrated between the LDPE and water in 5 hours. Although the high molecular weight PAHs with log KOW 5.6 ~ 6.8 was expected to be 2 to 30 days to reach the equilibrium, the Cfree of the PAHs at equilibrium could be corrected using performance reference compounds in 5 hours. Meanwhile, the total Cfree of PAHs were from 0.32 to 1.2 ng/L, which were higher than reported values in other oceans, but lower than in coastal water such as estuary, harbor, or shore. A bioavailability from the detected PAHs was highest at the sampling line near the dumping site of the Yellow Sea. Predicted residual concentrations in biota were relatively higher in offshore including the dumping site than in coastal regions.