• Title/Summary/Keyword: 모터 속도

Search Result 740, Processing Time 0.029 seconds

The Brassica rapa Tissue-specific EST Database (배추의 조직 특이적 발현유전자 데이터베이스)

  • Yu, Hee-Ju;Park, Sin-Gi;Oh, Mi-Jin;Hwang, Hyun-Ju;Kim, Nam-Shin;Chung, Hee;Sohn, Seong-Han;Park, Beom-Seok;Mun, Jeong-Hwan
    • Horticultural Science & Technology
    • /
    • v.29 no.6
    • /
    • pp.633-640
    • /
    • 2011
  • Brassica rapa is an A genome model species for Brassica crop genetics, genomics, and breeding. With the completion of sequencing the B. rapa genome, functional analysis of the genome is forthcoming issue. The expressed sequence tags are fundamental resources supporting annotation and functional analysis of the genome including identification of tissue-specific genes and promoters. As of July 2011, 147,217 ESTs from 39 cDNA libraries of B. rapa are reported in the public database. However, little information can be retrieved from the sequences due to lack of organized databases. To leverage the sequence information and to maximize the use of publicly-available EST collections, the Brassica rapa tissue-specific EST database (BrTED) is developed. BrTED includes sequence information of 23,962 unigenes assembled by StackPack program. The unigene set is used as a query unit for various analyses such as BLAST against TAIR gene model, functional annotation using MIPS and UniProt, gene ontology analysis, and prediction of tissue-specific unigene sets based on statistics test. The database is composed of two main units, EST sequence processing and information retrieving unit and tissue-specific expression profile analysis unit. Information and data in both units are tightly inter-connected to each other using a web based browsing system. RT-PCR evaluation of 29 selected unigene sets successfully amplified amplicons from the target tissues of B. rapa. BrTED provided here allows the user to identify and analyze the expression of genes of interest and aid efforts to interpret the B. rapa genome through functional genomics. In addition, it can be used as a public resource in providing reference information to study the genus Brassica and other closely related crop crucifer plants.

Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture - (트랙터부착형 타워집재기 개발(I) - 설계 및 제작-)

  • Park, Sang-Jun;Kim, Bo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This study was conducted to develop a mobile tower-yarder with tractor for agriculture and forestry that is the efficient yarder in steep terrains, thinning operation and small scale logging operation. It was designed and manufactured that the power source of tower-yarder is equiped three hydraulic pump connected to PTO of tractor, and three hydraulic pump is used to operate the four motor for drum, the cylinder for clutch of interlocker, the cylinder for tower expanding and the out-rigger cylinder. It was to adopt the running skyline system and the inter-lock function, and to equip the double capstan drum, the storage drum and the clutch for interlock in the development of tower-yarder. It was to develop the tower-yarder which the winch torque of double-capstan drum, the traction force of double-capstan drum, the number of rotation of double-capstan drum and the line speed is $191kg{\cdot}m$, 1,910 kgf, 220.5 rpm and 138.5 m/min, respectively. And it was known that the optimum flange diameter of the main and haulback storage drum is about 360 mm and about 460 mm in order to storage the main line length of 250m and the haulback line length of 450 m. The carriage was made to adopt the running skyline system and to equip the lock function in order to the convenience of chocking and the fall down preventing of tree. It was provided to develop the wire remote controller for the inter-lock function, the convenience of control and the efficiency of yarding. In development process, this tower-yarder was attached the 3-point linkage hitch equipment and the tire wheel for the traction and moving of tower-yarder. Also, it was equipped that the out-rigger and the guy line in order to raise the safety and efficiency of yarding of tower-yarder.

Efficiency Analysis of Spiral Structured Twist Screen (식품분말 진동선별기 개선을 위한 구조물 효율 분석)

  • Park, In-soon;Na, En-soo;Jang, Dong-soon;Paek, Young-soo
    • Food Engineering Progress
    • /
    • v.14 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • In the food process, twist screen is widely used to divide particles on the basis of size. As screen equipped in the twist screen perfoms an important part in the particle size distribution mechanism, the contact area of screen and particles, retention time of particles on the screen, mesh and string thickness of screen and the flow pattern of particles on the screen are major points of the separation efficiency. To improve the separation efficiency, increase the retention time and control the flow pattern of particles, screen frame dam and spiral blockage are installed on the sieve of twist screen ${\emptyset}$ 1200 and ${\emptyset}$ 1500. Twist screen ${\emptyset}$ 1500 with frame dam treated similar separation capacity, 37% higher separation ratio and less non-separated particles of product output 1 than general twist screen. Twist screens with frame dam and spiral blockage showed less treatment capacity, three times higher division ratio and entire separation than general twist screen.

Development of Prediction Model for Capsaicinoids Content in Red-Pepper Powder Using Near-Infrared Spectroscopy - Particle Size Effect (근적외선 스펙트럼을 이용한 고춧가루의 캡사이신 함량 예측 모델 개발 - 입자의 영향)

  • Mo, Changyeun;Kang, Sukwon;Lee, Kangjin;Lim, Jong-Guk;Cho, Byoung-Kwan;Lee, Hyun-Dong
    • Food Engineering Progress
    • /
    • v.15 no.1
    • /
    • pp.48-55
    • /
    • 2011
  • In this research, the near-infrared absorption from 1,100-2,300 nm was used to measure the content of capsaicinoids in the red-pepper powder by using the Acousto-optic tunable filters (AOTF) spectrometer with sample plate and sample rotating unit. Non-spicy red-pepper samples from one location (Younggwang-gun. Korea) were mixed with spicy one (var. Chungyang) to make samples separated by particle size (below 0.425 mm, 0.425-0.71 mm, and 0.71- 1.4 mm). The Partial Least Squares Regression (PLSR) model to predict the capsaicinoid content on particle sizes was developed with measured spectra by AOTF spectrometer and used to analyze the amount of capsaicinoids by HPLC. The PLSR Model of red-pepper powder of below 0.425 mm, 0.425-0.71 mm, and 0.71-1.4 mm with cross validation had ${R_V}^2$ = 0.948-0.979 and Standard Error of Prediction (SEP) = 6.56-7.94 mg%. The prediction error of smaller particle size of red-pepper powder was low. The best PLSR model was found in pretreatment of Range Normalization, Standard Normal Variate, and 1st Derivatives of red-pepper powder of below 1.4 mm with cross validation, having ${R_V}^2$ = 0.959 and SEP = 8.82 mg%.

Prediction of field failure rate using data mining in the Automotive semiconductor (데이터 마이닝 기법을 이용한 차량용 반도체의 불량률 예측 연구)

  • Yun, Gyungsik;Jung, Hee-Won;Park, Seungbum
    • Journal of Technology Innovation
    • /
    • v.26 no.3
    • /
    • pp.37-68
    • /
    • 2018
  • Since the 20th century, automobiles, which are the most common means of transportation, have been evolving as the use of electronic control devices and automotive semiconductors increases dramatically. Automotive semiconductors are a key component in automotive electronic control devices and are used to provide stability, efficiency of fuel use, and stability of operation to consumers. For example, automotive semiconductors include engines control, technologies for managing electric motors, transmission control units, hybrid vehicle control, start/stop systems, electronic motor control, automotive radar and LIDAR, smart head lamps, head-up displays, lane keeping systems. As such, semiconductors are being applied to almost all electronic control devices that make up an automobile, and they are creating more effects than simply combining mechanical devices. Since automotive semiconductors have a high data rate basically, a microprocessor unit is being used instead of a micro control unit. For example, semiconductors based on ARM processors are being used in telematics, audio/video multi-medias and navigation. Automotive semiconductors require characteristics such as high reliability, durability and long-term supply, considering the period of use of the automobile for more than 10 years. The reliability of automotive semiconductors is directly linked to the safety of automobiles. The semiconductor industry uses JEDEC and AEC standards to evaluate the reliability of automotive semiconductors. In addition, the life expectancy of the product is estimated at the early stage of development and at the early stage of mass production by using the reliability test method and results that are presented as standard in the automobile industry. However, there are limitations in predicting the failure rate caused by various parameters such as customer's various conditions of use and usage time. To overcome these limitations, much research has been done in academia and industry. Among them, researches using data mining techniques have been carried out in many semiconductor fields, but application and research on automotive semiconductors have not yet been studied. In this regard, this study investigates the relationship between data generated during semiconductor assembly and package test process by using data mining technique, and uses data mining technique suitable for predicting potential failure rate using customer bad data.

A Research on Ball-Balancing Robot (볼 벨런싱 로봇에 관한 연구)

  • Kim, Ji-Tae;Kim, Dae-young;Lee, Won-Joon;Jin, Tae-Seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.463-466
    • /
    • 2017
  • The purpose of this paper is to develop a module capable of all-directional driving different from conventional wheeled robots, and to solve the problems of the conventional mobile robot with side driving performance degradation, It is possible to overcome the disadvantages such as an increase in the time required for the unnecessary driving. The all - direction spherical wheel drive module for driving a ball - balancing robot is required to develop a power transfer mechanism and a driving algorithm for driving the robot in all directions using three rotor casters. 3DoF (Axis) A driver with built-in forward motion algorithm is embedded in the module and a driving motor module with 3DoF (axis) for driving direction and speed is installed. The movement mechanism depends on the sum of the rotation vectors of the respective driving wheels. It is possible to create various movement directions depending on the rotation and the vector sum of two or three drive wheels. It is possible to move in different directions according to the rotation vector field of each driving wheel. When a more innovative all-round spherical wheel drive module for forward movement is developed, it can be used in the driving part of the mobile robot to improve the performance of the robot more technically, and through the forward-direction robot platform with the drive module Conventional wheeled robots can overcome the disadvantage that the continuous straightening performance is lowered due to resistance to various environments. Therefore, it is necessary to use a full-direction driving function as well as a cleaning robot and a mobile robot applicable in the Americas and Europe It will be an essential technology for guide robots, boarding robots, mobile means, etc., and will contribute to the expansion of the intelligent service robot market and future automobile market.

  • PDF

Isolation and Characterization of mas1+ of Schizosaccharomyces pombe, a Homologue of Human CIP29/Hcc-1 Involved in the Regulation of Cell Division (세포분열에 관여하는 인간의 CIP29/Hcc1 유전자와 상동성을 가지는 분열형 효모의 새로운 유전자 mas1+의 특성분석)

  • Cha, Jae-Young;Shin, Sang-Min;Ha, Se-Eun;Lee, Jung-Sup;Park, Jong-Kun
    • Journal of Life Science
    • /
    • v.21 no.12
    • /
    • pp.1666-1677
    • /
    • 2011
  • The regulation of gene expression plays an important role in cell cycle controls. In this study, a novel gene, the $mas1^+$($\underline{mi}$tosis $\underline{as}$sociated protein) gene, a homolog of human CIP29/Hcc1, was isolated and characterized from fission yeast Schizosaccharomyces pombe (S. pombe) using a gene-specific polymerase chain reaction. The isolated gene contained a complete open reading frame capable of encoding 245 amino acid residues with a typical promoter, as judged by nucleotide sequence analysis. It was also found that a PCB ($\underline{p}$ombe cell $\underline{c}$ycle $\underline{b}$ox) is located in the promoter region, which controls M-$G_1$ specific transcription in S. pombe. The quantitative analysis of the $mas1^+$ transcript against $adh1^+$ showed that the pattern of expression is similar to that of the septation index. Cytokinesis of mas1 mutant was greatly delayed at $25^{\circ}C$ and $36^{\circ}C$, and a large number of multi-septate cells were produced. The mas1 mutant had 2C, 4C and 6C DNA contents, as determined by FACS analysis. In addition, the number of multi-septate cells significantly increased. When cells were cultured in nitrogen starvation medium to increase proliferation, the abnormal phenotypes of mas1 mutant dramatically increased. These phenotypes could be rescued by an overexpression of the $mas1^+$ gene. The mas1 protein localized in the nuclei of S. pombe and human HeLa cells, as evidenced by Mas1-EGFP signals. The abnormal growth pattern and the morphology of mas1 mutant were complemented by a plasmid carrying human CIP29/Hcc-1cDNA. In addition, CIP29 /Hcc-1 transcript level increased in active cell proliferation stages in the developing mouse embryos. These results indicate that the $mas1^+$ ishomologous to the human CIP29/Hcc1 gene and is involved in cytokinesis and cell shape control.

EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS (반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석)

  • Hwang, Soo-Youn;Oh, So-Ram;Lee, Yoon;Lim, Sang-Min;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 2009
  • This study aimed to assess the influence of different cross-sectional area on the cyclic fatigue fracture of Ni-Ti rotary files using a fatigue tester incorporating cyclical axial movement. Six brands of Ni-Ti rotary files (ISO 30 size with. 04 taper) of 10 each were tested: Alpha system (KOMET), HeroShaper (MicroMega), K3 (SybronEndo), Mtwo (VDW), NRT (Mani), and ProFile (Dentsply). A fatigue-tester (Denbotix) was designed to allow cyclic tension and compressive stress on the tip of the instrument. Each file was mounted on a torque controlled motor (Aseptico) using a 1:20 reduction contra-angle and was rotated at 300 rpm with a continuous, 6 mm axial oscillating motion inside an artificial steel canal. The canal had a $60^{\circ}$ angle and a 5 mm radius of curvature. Instrument fracture was visually detected and the time until fracture was recorded by a digital stop watch. The data were analyzed statistically. Fractographic analysis of all fractured surfaces was performed to determine the fracture modes using a scanning electron microscope. Cross-sectional area at 3 mm from the tip of 3 unused Ni-Ti instruments for each group was calculated using Image-Pro Plus (Imagej 1.34n, NIH). Results showed that NRT and ProFile had significantly longer time to fracture compared to the other groups (p < .05). The cross-sectional area was not significantly associated with fatigue resistance. Fractographycally, all fractured surfaces demonstrated a combination of ductile and brittle fracture. In conclusion, there was no significant relationship between fatigue resistance and the cross-sectional area of Ni-Ti instruments under experimental conditions.

Determination of Freely Dissolved PAHs in Seawater around the Korean Peninsula Using High Speed Rotation-Type Passive Sampling Device (고속회전식 수동형 채집 장치를 이용한 한반도 주변해역에서의 자유용존상 PAHs 측정)

  • JANG, YU LEE;LEE, HYO JIN;JEONG, HAEJIN;JEONG, DA YEONG;KIM, NA YEONG;KIM, GI BEUM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.26 no.1
    • /
    • pp.37-48
    • /
    • 2021
  • A new high speed rotation type-passive sampling device (HSR-PSD), which can rotate seawater at high speed and absorb easily and quickly the freely dissolved hydrophobic organic contaminants from seawater, was developed and then applied around the Korean Peninsula. Freely dissolved concentrations (Cfree) of polycyclic aromatic hydrocarbons (PAHs) were determined using the HSR-PSD with low density polyethylene (LDPE) sheets as a passive sampler. Furthermore, dissolved concentrations (Cdissolved) of PAHs in seawater were also obtained from high volume water sampling as a conventional method to account for actual bioavailability. When the LDPE sheets were rotated in the HSR-PSD at 900 rpm, PAHs with log KOW 3.4 ~ 5.2 were equilibrated between the LDPE and water in 5 hours. Although the high molecular weight PAHs with log KOW 5.6 ~ 6.8 was expected to be 2 to 30 days to reach the equilibrium, the Cfree of the PAHs at equilibrium could be corrected using performance reference compounds in 5 hours. Meanwhile, the total Cfree of PAHs were from 0.32 to 1.2 ng/L, which were higher than reported values in other oceans, but lower than in coastal water such as estuary, harbor, or shore. A bioavailability from the detected PAHs was highest at the sampling line near the dumping site of the Yellow Sea. Predicted residual concentrations in biota were relatively higher in offshore including the dumping site than in coastal regions.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF