Kim, Sang-jin;Kwon, Min-ho;Kim, Hyo-jun;Choi, Se-wan;Hwang, Dong-ok;Lee, Dong-ju;Paik, Seok-min
Proceedings of the KIPE Conference
/
2017.07a
/
pp.339-340
/
2017
본 논문은 에너지 저장시스템(ESS)과 무정전 전원장치(UPS)를 하나로 통합한 새로운 하이브리드 ESS-UPS 시스템을 제안한다. 제안하는 시스템은 ESS와 UPS를 하나로 통합함으로써 전력변환 시스템(PCS)의 가격을 줄이고 배터리의 이용률을 높일 수 있다. 또한 기존의 on-line UPS와는 달리 두 종류의 중요부하를 구성할 수 있어 PCS의 용량대비 비상발전 용량을 증대시키는 것이 가능하다. 본 논문에서는 제안하는 하이브리드 ESS-UPS 시스템의 운영 전략 및 급속 모드전환 알고리즘을 제안하며, 5kW급 축소 시작품을 통한 실험 결과로 타당성을 입증하였다.
Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo;Kwon, Sam-Young;Park, Hyun-June;Han, Kyung-Hee
Proceedings of the KSR Conference
/
2008.11b
/
pp.310-315
/
2008
Authors design a rotary-type small-scaled linear induction motor(LIM) and a performance test machine before manufacturing a real-scaled LIM for a railway transit. The designed LIM is a single-sided, short primary type and its primary has 4 poles. The rated power is 10(kW). In order to analyze characteristics of the LIM, authors use a mixed 2D-3D FEM analysis. 3-D FEM analysis is used for calculating a distribution of eddy-current on the semi-caped AL-sheet of the secondary reaction. Authors calculate a correction factor of conductivity and an equivalent conductivity on the secondary AL-sheet using a normalized eddy-current. The equivalent conductivity which is calculated in this way includes a transverse edge-effect of the LIM. Authors apply the equivalent conductivity on the secondary AL-sheet of 2D-FEM model and get performance characteristics of the LIM. Basic characteristics such as thrust and normal force, input current, efficiency and power factor of the LIM have been analyzed with the variation of frequency and speed. In order to apply an air-gap control system, the variation of the basic characteristics have been analyzed with the air-gap length variation of the LIM. Finally, authors introduce an operation mode using the air-gap control system and conduct a research on feasibility of the system.
Kim, June-Hyong;Nam, Sung-Soo;Cho, Tae-Joon;Lee, Hong-Min
The Journal of Korean Institute of Electromagnetic Engineering and Science
/
v.20
no.2
/
pp.147-153
/
2009
In this paper, FSS(Frequency Selective Surface) using defect mode characteristic is proposed. The unit cell using defect mode characteristic of the proposed FSS is offered lower resonant frequency in the same cell size. The number of suitable array is optimized 13 by 13. Also, the patch antennas operated in WCDMA(Wideband Code Division Multiple Access) Tx band and Rx band are designed for the comparison. The gain value of proposed FSS-1 complex structure (the patch antenna of Tx band and FSS) is improved 3.3 dB from 9.98 dBi to 13.28 dBi in Tx band. The gain value of proposed FSS-2 complex structure(the patch antenna of Rx band and FSS) is improved 5.53 dB from 9.81 dBi to 15.34 dBi in Rx band. Also the measured impedance bandwidth($VSWR{\leq}2$) of manufactured $13{\times}13$ array antenna is from 337 MHz(1.87 to 2.21 GHz). The measured radiation gain is 11.39 dBi(1.94 GHz), 13.11 dBi(2.05 GHz), 11.09 dBi(2.14 GHz). The measured radiation efficiency is 81 %. Because the proposed FSS structure has more higher gain, it will be applied to antenna of WCDMA repeater system.
Journal of the Korea Academia-Industrial cooperation Society
/
v.17
no.9
/
pp.21-26
/
2016
This paper presents a step-down DC-DC buck converter with a CCM/DCM dual-mode function for the internal power stage of portable electronic device. The proposed converter that is operated with a high frequency of 1 MHz consists of a power stage and a control block. The power stage has a power MOS transistor, inductor, capacitor, and feedback resistors for the control loop. The control part has a pulse width modulation (PWM) block, error amplifier, ramp generator, and oscillator. In this paper, an external capacitor for compensation has been replaced with a multiplier equivalent CMOS circuit for area reduction of integrated circuits. In addition, the circuit includes protection block, such as over voltage protection (OVP), under voltage lock out (UVLO), and thermal shutdown (TSD) block. The proposed circuit was designed and verified using a $0.18{\mu}m$ CMOS process parameter by Cadence Spectra circuit design program. The SPICE simulation results showed a peak efficiency of 94.8 %, a ripple voltage of 3.29 mV ripple, and a 1.8 V output voltage with supply voltages ranging from 2.7 to 3.3 V.
AT-DMB system has been developed to increase data rate up to double of conventional T-DMB in the same bandwidth while maintaining backward compatibility. The AT-DMB system adopted hierarchical modulation which adds BPSK or QPSK signal as enhancement layer to existing DQPSK signal. The enhancement layer signal should be small enough to maintain backward compatibility and to minimize the coverage loss of conventional T-DMB service coverage. But this causes the enhancement layer signal of AT-DMB susceptible to fading effect in transmission channel. A turbo code which has improved error correction capability than convolutional code, is applied to the enhancement layer signal of the AT-DMB system for compensating channel distortion. However there is a need for other solutions for better reception of AT-DMB signal in receiver side without increasing transmitting power. In this paper, we propose adaptive array antenna system with Eigen-space beamforming algorithm which benefits beamforming gain along with diversity gain. We analyzed the reception performances of AT-DMB system in indoor and mobile environments when this new smart antenna system and algorithm is introduced. The computer simulation results are presented along with analysis comments.
Journal of the Korean Society for Aeronautical & Space Sciences
/
v.38
no.4
/
pp.395-402
/
2010
Baffle injectors are protruded into the combustion chamber and form an anti-pulsating baffle to prevent high-frequency combustion instabilities in transverse modes. Being exposed to a high heat-flux environment, the baffle injector has self-cooling passages through which kerosene is convected and heated. The baffle injector with 20 spiral cooling channels has been developed and successfully applied to 30 $ton_f$-class combustors without any performance loss due to an additional cooling. In this work, numerical analysis of conjugate heat transfer in baffle injectors with various cooling channel designs has been performed in order to reduce the fabrication cost which would be considerably increased for the 75 $ton_f$-class combustor. Prior to the application to a full-scale combustor, the thermal durability of the modified design has been verified through the subscale hot-firing tests.
The Transactions of the Korean Institute of Power Electronics
/
v.3
no.4
/
pp.307-314
/
1998
A novel high power factor Dual Half Bridge Series Resonant Inverter (DHB-SRI) for an induction heating appliance with multiple loads is proposed to remove the interferential acoustic noise caused by the difference between operating frequencies of adjacent loads. The circuit enables independent full power range control of two induction heating elements by one inverter circuit and has minimum switching losses due to the zero voltage switching characteristic. According to the mode analysis, I will explain the operation of the proposed circuit. To evaluate the required cooling capacity, loss analysis is performed through deriving some loss equations. In order to obtain the power factor correction capability and to lessen the system size, suitable design guides are given. Using the designed values, the proto-type circuit with 2.8kW power consumption for each induction heating element is built and tested to verify the operation of the proposed circuit.
Journal of the Earthquake Engineering Society of Korea
/
v.9
no.2
s.42
/
pp.1-6
/
2005
The purpose of this paper is to evaluate the performance of an MR fluid damper for seismic vibration control of a structure in terms of equivalent linear damping based on linearization technique and to experimentally verify the results from linearization technique by comparing them to those from system identification testing of a building structure with the MR damper. First, among various models for the MR damper, the equivalent damping is estimated for the Bingham model which is mathematically simple. Second, the transfer function of a building structure with the MR damper is obtained by performing shaking table tests and the damping matrices of the structure are constructed using the modal information obtained by the transfer function. It is observed that the damping mathematically estimated using linearization technique for the Bingham model matches well with the damping coefficient experimentally obtained by system identification.
Kim, Kang Seok;Nah, Hwan Seon;Lee, Hyeon Ju;Lee, Kang Min;Yoo, Kyung Seok
Journal of the Korea institute for structural maintenance and inspection
/
v.15
no.1
/
pp.120-128
/
2011
Recently, safety diagnosis of the existing structures has been emerged as important issue. In particular, systematical and precise safety diagnostics for steel structures for power substation, have been required. Steel structures for power substation are under the periodical impact loads from operations of gas insulated switchgear. These loading condition accelerates damage and aging of structure. The objective of this research is to evaluate damage of structure under periodical impact loads. To evaluate the integrity of structures as organizing mathematical models including the dynamic characteristics of structures, Frequency Domain Decomposition method was choiced and an algorism was proposed. For verifying this methods and algorism, a mathematical model is composed of the development of a variety of reverse analysis and a signal processing technology reflecting physical damage of structures. A series of analysis and test results indicatge that proposed method has a confidence for applying a filed test. Therefore, it is expected to be able to take advantage of system identification to detect damage for the maintenance and management of steel structures under periodical impact loads such as power substation.
태양열 발전 플랜트에 사용되는 중고온 범위의 축열조에 고체-액체간 상변화를 수행하는 용융염을 축열물질로 사용하면 액체상 또는 고체상만으로 된 열저장 매체에 비해 축열조의 규모를 축소함과 동시에 축열온도의 균일성 향상에 기여할 수 있다. 중온인 $250{\sim}400^{\circ}C$ 범위에서 이용 가능한 용융염으로는 질산칼륨($KNO_3$), 질산리튬($LiNO_3$)등이 있다. 그러나 이러한 용융염의 가장 큰 단점은 열전도율이 매우 낮다는 것이며, 이로 인해 요구되는 열전달률을 성취하기 위해서는 많은 열접촉면적이 필요하다는 것이다. 이러한 단점을 극복하는 방법을 도입하지 않고서는 축열시스템의 소규화를 성취하는데 큰 효과를 가져올 수 없다. 한편 열수송 성능이 탁월한 히트파이프를 사용하면 열원 및 열침과 축열물질 사이의 열전달 효율을 증가시켜 시스템의 성능 향상과 동시에 소규모화에 기여할 수 있다. 중온 범위 히트파이프의 작동유체로서 다우섬-A(Dowtherm-A)는 $150^{\circ}C$이상 $400^{\circ}C$까지의 범위에서 소수에 불과한 선택적 대안 중 하나이다. 따라서 본 연구에서는 용융염을 사용하는 중온 태양열축열조에 적용 가능한 다우섬-A 히트파이프의 성능을 파악하여 기술적 자료를 제시하고자 하였다. 열원으로는 고온 고압의 과열증기, 그리고 열침으로는 중온의 포화증기를 고려하였다. 용융염 축열조를 수직으로 관통하는 히트파이프는 하단부에서 열원 증기와 열교환 가능하며, 중앙부에서 축열물질과 열교환하고, 상단부에서는 중온 증기와 접촉할 수 있도록 배치하였다. 축열모드에서는 히트파이프의 하단부가 증발부로 작동하고, 중앙부가 응축부로 작동하여 용융염으로 열을 방출하면 용융염의 온도가 상승하고 용융점에 도달하면 액상으로의 상변화가 진행되면서 축열이 활성화된다. 축열모드에서 히트파이프의 상단부는 단열부로 작동한다. 방열과정에서는 히트파이프의 하단부가 단열된 상태이고, 중앙부는 용융염으로부터 열을 받아 증발부로 작동하며, 상단부는 중온 증기로 열을 방출하므로 응축부로 작동한다. 즉, 축열시스템의 작동모드에 따라 하나의 히트파이프에서 증발부, 응축부, 단열부의 위치가 변하게 된다. 특히, 히트파이프의 중앙 부분이 응축부에서 증발부로 전환될 때에도 작동이 보장되려면 내부 작동유체의 연속적인 재순환이 가능해야 하므로, 일반 히트파이프에서와는 달리 초기 작동액체의 충전량을 증발부 전체의 체적보다 더 많이 과충전해야 한다. 이러한 히트파이프의 성능 파악을 위한 실험에서 고려한 변수들은 열부하, 작동액체의 충전률, 작동온도 등이며, 열수송 성능의 지표로서는 유효열전도율과 열저항을 이용하였다. 중온범위에서 적정한 작동온도를 성취하기 위해 실험에서는 전압 조절기로 열부하를 조절하는 동시에 항온조로 응축부의 냉각수 입구 온도를 제어하였다. 하나의 히트파이프에 대해서 최대 1 kW까지의 열부하에서 냉각수 입구 온도를 $40^{\circ}C$에서 $80^{\circ}C$ 범위로 변화시키면 히트파이프 작동온도를 약 $250^{\circ}C$ 내외로 조절 가능하였다. 히트파이프 작동액체 충전률은 윅구조물의 공극 체적을 기준으로 372%에서 420%까지 변화 시켰다. 실험 결과를 토대로 열저항과 유효 열전도율을 각각 입력 열유속, 작동온도, 작동액체 충전률 등의 함수로 제시했다. 동일한 냉각수 온도에서는 충전률이 높을수록 히트파이프의 작동온도가 감소하였다. 열저항 값의 범위는 최소 $0.12^{\circ}C/W$에서 최대 $0.15^{\circ}C/W$까지로 나타났으며 유효 열전도율의 값은 최소 $7,703W/m{\cdot}K$에서 최대 $8,890W/m{\cdot}K$까지 변화했다. 최소 열저항은 충전률 420%인 경우에 나타났는데 이때의 작동온도는 약 $262^{\circ}C$이었다. 히트파이프의 작동한계로서 드라이아웃(dry-out)은 충전률 372%의 경우에 열부하 950 W에서 발생하였으나, 그 이상의 충전률에서는 열부하 1060 W까지 작동한계 발생이 관찰되지 않았다. 실험 결과 본 연구에서의 히트파이프는 중온 태양열 축열조에 적용되어 개당 약 1 kW의 열부하를 이송하면서 축열물질 및 축방열 대상 유동매체와 열교환을 하는데 사용하는데 충분할 것이라 판단된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.