Independent Verification Program for High-Dose-Rate Brachytherapy Treatment Plans (고선량률 근접치료계획의 정도보증 프로그램)

  • Han Youngyih;Chu Sung Sil;Huh Seung Jae;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.21 no.3
    • /
    • pp.238-244
    • /
    • 2003
  • Purpose: The Planning of High-Dose-Rate (HDR) brachytherapy treatments are becoming individualized and more dependent on the treatment planning system. Therefore, computer software has been developed to perform independent point dose calculations with the integration of an isodose distribution curve display into the patient anatomy images. Meterials and Methods: As primary input data, the program takes patients'planning data including the source dwell positions, dwell times and the doses at reference points, computed by an HDR treatment planning system (TPS). Dosimetric calculations were peformed in a $10\times12\times10\;Cm^3$ grid space using the Interstitial Collaborative Working Group (ICWG) formalism and an anisotropy table for the HDR Iridium-192 source. The computed doses at the reference points were automatically compared with the relevant results of the TPS. The MR and simulation film images were then imported and the isodose distributions on the axial, sagittal and coronal planes intersecting the point selected by a user were superimposed on the imported images and then displayed. The accuracy of the software was tested in three benchmark plans peformed by Gamma-Med 12i TPS (MDS Nordion, Germany). Nine patients'plans generated by Plato (Nucletron Corporation, The Netherlands) were verified by the developed software. Results: The absolute doses computed by the developed software agreed with the commercial TPS results within an accuracy of $2.8\%$ in the benchmark plans. The isodose distribution plots showed excellent agreements with the exception of the tip legion of the source's longitudinal axis where a slight deviation was observed. In clinical plans, the secondary dose calculations had, on average, about a $3.4\%$ deviation from the TPS plans. Conclusion: The accurate validation of complicate treatment plans is possible with the developed software and the qualify of the HDR treatment plan can be improved with the isodose display integrated into the patient anatomy information.

Estimation of Jaw and MLC Transmission Factor Obtained by the Auto-modeling Process in the Pinnacle3 Treatment Planning System (피나클치료계획시스템에서 자동모델화과정으로 얻은 Jaw와 다엽콜리메이터의 투과 계수 평가)

  • Hwang, Tae-Jin;Kang, Sei-Kwon;Cheong, Kwang-Ho;Park, So-Ah;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.269-276
    • /
    • 2009
  • Radiation treatment techniques using photon beam such as three-dimensional conformal radiation therapy (3D-CRT) as well as intensity modulated radiotherapy treatment (IMRT) demand accurate dose calculation in order to increase target coverage and spare healthy tissue. Both jaw collimator and multi-leaf collimators (MLCs) for photon beams have been used to achieve such goals. In the Pinnacle3 treatment planning system (TPS), which we are using in our clinics, a set of model parameters like jaw collimator transmission factor (JTF) and MLC transmission factor (MLCTF) are determined from the measured data because it is using a model-based photon dose algorithm. However, model parameters obtained by this auto-modeling process can be different from those by direct measurement, which can have a dosimetric effect on the dose distribution. In this paper we estimated JTF and MLCTF obtained by the auto-modeling process in the Pinnacle3 TPS. At first, we obtained JTF and MLCTF by direct measurement, which were the ratio of the output at the reference depth under the closed jaw collimator (MLCs for MLCTF) to that at the same depth with the field size $10{\times}10\;cm^2$ in the water phantom. And then JTF and MLCTF were also obtained by auto-modeling process. And we evaluated the dose difference through phantom and patient study in the 3D-CRT plan. For direct measurement, JTF was 0.001966 for 6 MV and 0.002971 for 10 MV, and MLCTF was 0.01657 for 6 MV and 0.01925 for 10 MV. On the other hand, for auto-modeling process, JTF was 0.001983 for 6 MV and 0.010431 for 10 MV, and MLCTF was 0.00188 for 6 MV and 0.00453 for 10 MV. JTF and MLCTF by direct measurement were very different from those by auto-modeling process and even more reasonable considering each beam quality of 6 MV and 10 MV. These different parameters affect the dose in the low-dose region. Since the wrong estimation of JTF and MLCTF can lead some dosimetric error, comparison of direct measurement and auto-modeling of JTF and MLCTF would be helpful during the beam commissioning.

  • PDF

Preliminary Investigations of the Dosimetric Properties of a Normoxic Polymethacrylic Acid Gel Dosimeter Using a Respiration-Motion Simulator (호흡모의움직임장치를 이용한 정상산소 폴리메타크릴산 겔 선량계의 선량특성)

  • Park, Chae Hee;Cho, Yu Ra;Cho, Kwang Hwan;Park, Ji Ae;Kim, Kyeong Min;Kim, Kum Bae;Jung, Hai Jo;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.138-144
    • /
    • 2012
  • Dose distribution throughout the clinical organ range of motion was analyzed using a respiratory-motion simulator that was equipped with a polymer gel dosimeter and EBT2 film. The normoxic polymer gel dosimeter was synthesized from gelatin, MAA, HQ, THPC and HPLC. The gel dosimeter and EBT2 film were irradiated with Co-60 gamma rays that were moved along the x-axis and y-axis in ${\pm}1.5cm$ steps at five-second intervals. The field size was $5{\times}5cm^2$. The SSD was 80 cm and set to 10 Gy at a depth of 2 cm. The PDD at a depth of 50 mm was 75.2% in the ion chamber, 82.3% in the static state and 86.1% in the dynamic state in the gel dosimeter. The penumbra for the dynamic state target, which was measured using the gel dosimeter, averaged 10.89 mm, this is a 40.5% increase over the penumbra of the static state target of 7.74 mm. In addition, when measuring with gel dosimetry, the value for the penumbra is 36.6% smaller in the static state and 29.4% smaller in the dynamic state compared to measuring with film. The aim of this study was to investigate the dosimetric properties of a normoxic polymethacrylic acid gel dosimeter in static and dynamic states and to evaluate the potentiality as a relative dosimeter for dynamic therapeutic radiation.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

Positional Change of the Uterus during Definitive Radiotherapy for Cervix Cancer (자궁경부암의 방사선치료 시 자궁의 크기와 위치 변화)

  • Park, Won;Huh, Seung-Jae;Lee, Jeung-Eun
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.135-142
    • /
    • 2003
  • Purpose: The purpose of this study was to investigate the positional change of the uterus during radiotherapy. Materials and Methods: Between 1997 and 2001, 47 patients received definitive radiotherapy for cervical cancer at the Samsung Medical Center. For each patient, two MRI scans were taken; one before and the other 3$\~$4 weeks after the radiotherapy treatment. In T2 weighted MRI images, the positional change of the uterine was quantified by measuring six quantities; the distance from the cervix os to the isthmus of the uterus (Dcx), the maximum length from the isthmus of the uterus to the uterine fundus (Dco), the maximum vertical distance of the uterine body (Dco-per), the angle between the vertical line and the cervical canal in the sagittal images (Acx), the angle of the uterine corpus from the vertical line in the sagittal plan (Aco-ap), and the relative angle of the uterine corpus from a fixed anatomical landmark in the axial images (Aco-axi). Results: The mean Dcx values, before and during the treatment, were 36.7 and 27.8 mm, respectively. The Dco deviated by more than 10 mm in 14 cases (29.8$\%$). The change in the Acx ranged from 0.1 to 67.8$^{\circ}$ (mean 13.2$^{\circ}$). The Aco-ap changed by a maximum of 84.8$^{\circ}$ (mean 16.9$^{\circ}$). The differences in the Dcx plus the Dco in the smaller (<4 cm) and larger ($geq$4 cm) tumors were 5.3 and 19.4 mm, respectively. With patients less than 60 years old, or with a tumor size larger than 4 cm, the difference in the Acx was statistically significant. Conclusion: The positional changes of the uterus, during radiation treatment, should be considered in the 3DCRT or IMRT treatment planning, particularly in patients under 60 years of age or in those with a tumor size greater than 4 cm in maximum diameter.

Investigation of Intertidal Zone using TerraSAR-X (TerraSAR-X를 이용한 조간대 관측)

  • Park, Jeong-Won;Lee, Yoon-Kyung;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.25 no.4
    • /
    • pp.383-389
    • /
    • 2009
  • The main objective of the research is a feasibility study on the intertidal zone using a X-band radar satellite, TerraSAR-X. The TerraSAR-X data have been acquired in the west coast of Korea where large tidal flats, Ganghwa and Yeongjong tidal flats, are developed. Investigations include: 1) waterline and backscattering characteristics of the high resolution X-band images in tidal flats; 2) polarimetric signature of halophytes (or salt marsh plants), specifically Suaeda japonica; and 3) phase and coherence of interferometric pairs. Waterlines from TerraSAR-X data satisfy the requirement of horizontal accuracy of 60 m that corresponds to 20 cm in average height difference while current other spaceborne SAR systems could not meet the requirement. HH-polarization was the best for extraction of waterline, and its geometric position is reliable due to the short wavelength and accurate orbit control of the TerraSAR-X. A halophyte or salt marsh plant, Suaeda japonica, is an indicator of local sea level change. From X-band ground radar measurements, a dual polarization of VV/VH-pol. is anticipated to be the best for detection of the plant with about 9 dB difference at 35 degree incidence angle. However, TerraSAR-X HH/TV dual polarization was turned to be more effective for salt marsh monitoring. The HH-HV value was the maximum of about 7.9 dB at 31.6 degree incidence angle, which is fairly consistent with the results of X-band ground radar measurement. The boundary of salt marsh is effectively traceable specifically by TerraSAR-X cross-polarization data. While interferometric phase is not coherent within normal tidal flat, areas of salt marsh where the landization is preceded show coherent interferometric phases regardless of seasons or tide conditions. Although TerraSAR-X interferometry may not be effective to directly measure height or changes in tidal flat surface, TanDEM-X or other future X-band SAR tandem missions within one-day interval would be useful for mapping tidal flat topography.

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

홍삼 유래 성분들의 면역조절 효능

  • Jo, Jae-Yeol
    • Food preservation and processing industry
    • /
    • v.8 no.2
    • /
    • pp.6-12
    • /
    • 2009
  • 면역반응은 외부 감염원으로부터 신체를 보호하고 외부감염원을 제거하고자 하는 주요항상성 유지기전의 하나이다. 이들 반응은 골수에서 생성되고 비장, 흉선 및 임파절 등에서 성숙되는 면역세포들에 의해 매개된다. 보통 태어나면서부터 얻어진 선천성 면역반응을 매개하는 대식세포, 수지상 세포 등과, 오랜기간 동안 감염된 다양한 면역원에 대한 경험을 토대로 얻어진 획득성 면역을 담당하는 T 임파구 등이 대표적인 면역세포로 알려져 있다. 다양한 면역질환이 최근 주요 사망률의 원인이 되고 있다. 최근, 암, 당뇨 및 뇌혈관질환 등이 생체에서 발생되는 급 만성염증에 의해 발생된다고 보고됨에 따라 면역세포 매개성 염증질환에 대한 치료제 개발을 서두르고 있다. 또한 암환자의 급격한 증가는 암발생의 주요 방어기전인 면역력 증강에 대한 요구들을 가중시키고 있다. 예로부터 사용되어 오던 고려인삼과 홍삼은 기를 보호하고 원기를 회복하는 명약으로 알려진 대표적인 우리나라 천연생약이다. 특별히, 홍삼은 단백질과 핵산의 합성을 촉진시키고, 조혈작용, 간기능 회복, 혈당강하, 운동수행 능력증대, 기억력 개선, 항피로작용 및 면역력 증대에 매우 효과가 좋은 것으로 보고되고 있다. 홍삼에 관한 많은 연구에 비해, 현재까지 홍삼이 면역력 증강에 미치는 효과에 대한 분자적 수준에서의 연구는 매우 미미한 것으로 확인되어져 있다. 홍삼의 투여는 NK 세포나 대식세포의 활성이 증가하고 항암제의 암세포 사멸을 증가시키는 것으로 확인되어졌다. 현재까지 알려진 주요 면역증강 성분은 산성다당류로 보고되었다. 또 한편으로 일부 진세노사이드류에서 항염증 효능이 확인되어졌으며, 이를 통해 피부염증 반응과 관절염에 대한 치료 효과가 있는 것으로 추측되고 있다 [본 연구는 KT&G 연구출연금 (2009-2010) 지원을 받아 이루어졌기에 이에 감사드린다]. 면역반응은 외부 감염물질의 침입으로 유도된 질병환경을 제거하고 수복하는 중요한 생체적 방어작용의 하나이다. 이들 과정은 체내로 유입된 미생물이나 미세화학물질들과 같은 독성물질을 소거하거나 파괴하는 것을 주요 역할로 한다. 외부로 부터 인체에 들어온 이물질에 대한 방어기전은 현재 두 가지 종류의 면역반응으로 구분해서 설명한다. 즉, 선천성 면역 반응 (innate immunity)과 후천성 면역 반응 (adaptive immunity)이 그것이다. 선천성 면역반응은 1) 피부나 점막의 표면과 같은 해부학적인 보호벽 구조와 2) 체온과 낮은 pH 및 chemical mediator (리소자임, collectin류) 등과 같은 생리적 방어구조, 3) phagocyte류 (대식세포, 수지상세포 및 호중구 등)에 의한 phagocytic/endocytic 방어, 그리고 4) 마지막으로 염증반응을 통한 감염에 저항하는 면역반응 등으로 구분된다. 후천성 면역반응은 획득성면역이라고도 불리고 특이성, 다양성, 기억 및 자기/비자기의 인식이라는 네 가지의 특징을 가지고 있으며, 외부 유입물질을 제거하는 반응에 따라 체액성 면역 반응 (humoral immune response)과 세포성 면역반응 (cell-mediated immune response)으로 구분된다. 체액성 면역은 침입한 항원의 구조 특이적으로 생성된 B cell 유래 항체와의 반응과 간이나 대식세포 등에서 합성되어 분비된 혈청내 보체 등에 의해 매개되는 반응으로 구성되어 있다. 세포성 면역반응은 T helper cell (CD4+), cytotoxic T cell (CD8+), B cell 및antigen presenting cell 중개를 통한 세포간 상호 작용에 의해 발생되는 면역반응이다. 선천성 면역반응의 하나인 염증은 우리 몸에서 가장 빈번히 발생되고 있는 방어작용의 하나이다. 예를 들면 감기에 걸렸을 경우, 환자의 편도선내 대식세포나 수지상세포류는 감염된 바이러스 단독 혹은 동시에 감염된 박테리아를 상대로 다양한 염증성 반응을 유도하게 된다. 또한, 상처가 생겼을 경우에도 감염원을 통해 유입된 병원성 세균과 주위조직내 선천성 면역담당 세포들 간의 면역학적 전투가 발생되게 된다. 이들 과정을 통해, 주위 세포나 조직이 손상되면, 즉각적으로 이들 면역세포들 (주로 phagocytes류)은 신속하게 손상을 극소화하고 더 나가서 손상된 부위를 원상으로 회복시키려는 일련의 염증반응을 유도하게 된다. 이들 반응은 우리가 흔히 알고 있는 발적 (redness), 부종 (swelling), 발열 (heat), 통증 (pain) 등의 증상으로 나타나게 된다. 즉, 손상된 부위 주변에 존재하는 모세혈관에 흐르는 혈류의 양이 증가하면서 혈관의 직경이 늘어나게 되고, 이로 인한 조직의 홍반과, 부어 오른 혈관에 의해 발열과 부종이 초래되는 것이다. 확장된 모세혈관의 투과성 증가는 체액과 세포들이 혈관에서 조직으로 이동하게 하는 원동력이 되고, 이를 통해 축적된 삼출물들은 단백질의 농도를 높여, 최종적으로 혈관에 존재하는 체액들이 조직으로 더 많이 이동되도록 유도하여 부종을 형성시킨다. 마지막으로 혈관 내 존재하는 면역세포들은 혈판 내벽에 점착되고 (margination), 혈관벽의 간극을 넓히는 역할을 하는 히스타민 (histamine)이나 일산화질소(nitric oxide : NO), 프로스타그린딘 (prostagladins : PGE2) 및 류코트리엔 (leukotriens) 등과 같은 chemical mediator의 도움으로 인해 혈관벽 사이로 삼출하게 되어 (extravasation), 손상된 부위로 이동하여 직접적인 외부 침입 물질의 파괴나 다른 면역세포들을 모으기 위한 cytokine (tumor necrosis factor [TNF]-$\alpha$, interleukin [IL]-1, IL-6 등) 혹은 chemokine (MIP-l, IL-8, MCP-l등)의 분비 등을 수행함으로써 염증반응을 매개하게 된다. 염증과정시 발생되는 여러 mediator 중 PGE2나 NO 및 TNF-$\alpha$ 등은 실험적 평가가 용이하여 이들 mediator 자체나 생성관련효소 (cyclooxygenase [COX] 및 nitric oxide synthase [NOS] 등)들은 현재항염증 치료제의 개발 연구시 주요 표적으로 연구되고 있다. 염증 반응은 지속기간에 따라 크게 급성염증과 만성염증으로 나뉘며, 삼출물의 종류에 따라서는 장액성, 섬유소성, 화농성 및 출혈성 염증 등으로 구분된다. 급성 염증 (acute inflammation)반응은 수일 내지 수주간 지속되는 일반적인 염증반응이라고 볼 수 있다. 국소반응은 기본징후인 발열과 발적, 부종, 통증 및 기능 상실이 특징적이며, 현미경적 소견으로는 혈관성 변화와 삼출물 형성이 주 작용이므로 일명 삼출성 염증이라고 한다. 만성 염증 (chronic inflammation)은, 급성 염증으로부터 이행되거나 만성으로 시작된다. 염증지속 기간은 보통 4주 이상 장기화 된다. 보통 염증의 경우에는 염증 생성 cytokine인 Th1 cytokine (IL-2, interferone [IFN]-$\gamma$ 및 TNF-$\alpha$ 등)의 생성 후, 거의 즉각적으로 항 염증성 cytokine인 Th2 cytokine(IL-4, IL-6, IL-10 및 transforming growth factor [TGF]-$\beta$ 등)이 생성되어 정상반응으로 회복된다. 그러나, 어떤 원인에서든 면역세포에 의한 염증원 제거 반응이 문제가 되면, 만성염증으로 진행된다. 이 반응에 주로 작용을 하는 염증세포로는 단핵구와 대식세포, 림프구, 형질세포 등이 있다. 암은 전세계적으로 사망률 1위의 원인이 되는 면역질환의 하나이다. 산화적 스트레스나 자외선 조사 혹은 암유발 물질들에 의해 염색체내 protooncogene, tumor-suppressor gene 혹은 DNA repairing gene의 일부 DNA의 돌연변이 혹은 결손 등이 발행되면 정상세포는 암화과정을 시작하게 된다. 양성세포 수준에서 약 5에서 10여년 후 악성수준의 암세포가 생성되게 되면 이들 세포는 새로운 환경을 찾아 전이하게 되는데 이를 통해 암환자들은 다양한 장기에 동인 오리진의 암세포들이 생성한 종양들을 가지게 된다. 이들 종양세포는 정상 장기의 기능을 손상시켜며 결국 생명을 잃게 만든다. 이들 염색체 수준에서의 돌연변이 유래 암세포는 거의 대부분이 체내 면역시스템에 의해 사멸되는 것으로 알려져 있다. 그러나 계속되는 스트레스나 암유발 물질의 노출은 체내 면역체계를 파괴하면서 최후의 방어선을 무너뜨리면서 암발생에 무방비 상태를 만들게 된다. 이런 이유로 체내 면역시스템의 정상적 가동 및 증강을 유도하게 하는 전략이 암예방시 매우 중요한 표적으로 인식되면서 다양한 형태의 면역증강 물질 개발을 시도하고 있다. 인삼은 두릅나무과의 여러해살이 풀로써, 오랜동안 한방 및 민간에서 원기를 회복시키고, 각종 질병을 치료할 수단으로 사용되고 있는 대표적인 전통생약이다. 예로부터 불로(不老), 장생(長生), 익기(益氣), 경신(經身)의 명약으로 구전되어졌는데, 이는 약 2천년 전 중국의 신농본초경(神農本草經)에서 "인삼은 오장(五腸)을 보하고, 정신을 안정시키고, 혼백을 고정하며 경계를 멈추게 하고, 외부로부터 침입하는 병사를 제거하여주며, 눈을 밝게 하고 마음을 열어 더욱 지혜롭게 하고 오랫동안 복용하면 몸이 가벼워지고 장수한다" 라고 기술되어있는 데에서 유래한 것이다. 다양한 연구를 통해 우리나라에서 생산되는 고려인삼 (Panax ginseng)이 효능 면에서 가장 탁월한 것으로 알려져 있으며 특별이 고려인삼으로부터 제조된 고려홍삼은 전세계적으로도 그 효능이 우수한 것으로 보고되어 있다. 대부분의 홍삼 약효는 dammarane계열의 triterpenoid인 ginsenosides라고 불리는 인삼 saponin에 의해 기인된 것으로 알려져 있다. 이들 화합물군의 기본 골격에 따라, protopanaxadiol (PD)계 (22종) 및 protopanaxatriol (PT)계 (10종)으로 구분되고 있다 (표 1). 실험적 접근을 통해 인삼의 약리작용 이해를 위한 다양한 노력들이 경주되고 있으나, 여전히 많은 부분에서 충분히 이해되고 있지 않다. 그러나, 현재까지 연구된 인삼의 약리작용 관련 연구들은 심혈관, 당뇨, 항암 및 항스트레스 등과 같은 분야에서 인삼효능이 우수한 것으로 보고하고 있다. 그러나 면역조절 및 염증현상과 관련된 최근 연구결과들은 많지 않으나, 향후 다양하게 연구될 효능부분으로 인식되고 있다.

  • PDF

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.