• Title/Summary/Keyword: 면표적

Search Result 132, Processing Time 0.029 seconds

Operational Concept Design and Verification for Airborne SAR System (항공탑재 SAR 시스템 운용개념 설계 및 검증)

  • Lee, Hyon-Ik;Kim, Se-Young;Jeon, Byeong-Tae;Sung, Jin-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.7
    • /
    • pp.588-595
    • /
    • 2013
  • Airborne SAR system is the imaging Radar system that is loaded on a manned or unmanned aircraft, which is in charge of high quality image acquisition and moving target detection. This paper describes the operational requirements for the Airborne SAR system and suggests the operational concept to satisfy the requirements. To be specific, it describes the interface with airborne system, state definition and transition, operation mode based on mission definition file, fault management, and data storing and transmission concept. Finally, it gives the ground test results to verify the SAR system operational concept.

A Study on Block Processing Approach for Mono-Static Terrain Imaging Radar (모노스태틱 지형 영상 레이더의 블록 처리 기법 연구)

  • Ha, Jong-Soo;Cho, Byung-Lae;Lee, Jung-Soo;Park, Gyu-Churl;Sun, Sun-Gu;Kang, Tae-Ha
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.549-557
    • /
    • 2013
  • This paper describes a block processing approach to detect targets in front of mono-static terrain imaging radar (TIR). It is difficult to employ several conventional imaging methods of the synthetic aperture radar(SAR) because the TIR is an ultra-wide-band(UWB) type of radar and employs a dechirp-on-receive process. To design an available imaging method, a block processing approach which conducts a range compression and an azimuth compression is proposed in this paper. The complete derivation of the proposed approach is presented. The results of simulations and field tests are demonstrated to show the performance and validity of the proposed approach.

Feasibility Study of Forward-Looking Imaging Radar Applicable to an Unmanned Ground Vehicle (무인 차량 탑재형 전방 관측 영상 레이다 가능성 연구)

  • Sun, Sun-Gu;Cho, Byung-Lae;Park, Gyu-Churl;Nam, Sang-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.11
    • /
    • pp.1285-1294
    • /
    • 2010
  • This study describes the design and verification of short range UWB(Ultra Wideband) imaging radar that is able to display high resolution radar image for front area of a UGV(Unmanned Ground Vehicle). This radar can help a UGV to navigate autonomously as it detects and avoids obstacles through foliage. We describe the relationship between bandwidth of transmitting signal and range resolution. A vivaldi antenna is designed and it's radiation pattern and reflection are measured. It is easy to make array antenna because of small size and thin shape. Aperture size of receiving array antenna is determined by azimuth resolution of radar image. The relation of interval of receiving antenna array, image resolution and aliasing of target on a radar image is analyzed. A vector network analyzer is used to obtain the reflected signal and corner reflectors as targets are positioned at grass field. Applicability of the proposed radar to UGV is proved by analysis of image resolution and penetrating capability for grass in the experiment.

The Study on Education and Training System for the Special Security Guards' Specialization (특수경비원 전문화를 위한 교육훈련제도 개선방향)

  • Kim, Jong-Woong;Lee, Sang-Chul
    • Korean Security Journal
    • /
    • no.17
    • /
    • pp.69-89
    • /
    • 2008
  • As year passes, terrorism is gradually increasing. Its target has becom various and arbitary, and recently, terrorists are aiming for national major facilities wich include multiplex facilities. Although special security guards took charge of its defence system from 2002, they have failed to establish its system firmly due to some institutional inertia. And 'Professionalism' appeared to be the mattter, according to the spot-probe and interviews. The purpose of this essay is to devise measures to develop sepecial security system including its specialization through investigating current educational training system. In order to attain professionalism, establishment of new proffessional school, division of current education system(into common education and full-course education), and reinforcement of substantial inspection activity should be preceded. Moreover, inspection activity should include standards for engaging instructors, establishment of compilation committee for editorial supervision, and establishment of clear educational policy. I hope the developmental measures in this essay to be speedily actualized with endeavor from police, security association, academic circles.

  • PDF

A Rapid Preparation of Carrier-Free Fluorine-38 for Medical Use

  • Kim, You-Sun;Kim, Jaerok
    • Nuclear Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1976
  • For tile rapid production of fluorine-18 for medical use, the up-to-date methods of separation such as the recoil separation, the alumina column chromatography, and the distillation are reviewed. The amount of the residue, the gamma emitting impurity, and the tritium content in the product obtained by each separation method are determined. The product obtained by the nuclear recoil separation or by the alumina column chromatography is inferior to that obtained by the distillation in the purity point of view. Thus, the separation by the distillation is tile most effective especially in the case of using a natural lithium carbonate target. Carrier free fluorine-18 of about 2 mCi can routinely be produced by irradiating 7g of the natural lithium carbonate under the neutron flux of about 1$\times$10$^{13}$ n/$\textrm{cm}^2$/sec for 3 hrs, and subsequent separation by the distillation. The over-all processing time is 35-40n1in.

  • PDF

Design of Sub-array Receiver for Active Phase Array Radar (능동위상배열 레이더 부배열 수신기 설계)

  • Yi, Hui-min;Kim, Do-hoon;Han, Il-tak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.5
    • /
    • pp.568-573
    • /
    • 2019
  • Modern Radars are evolving into MFRs which can search multiple targets simultaneously and then track them. Additionally they should be able to avoid some external jamming signals. Applying to these MFRs, Antennas should be able to perform DBF including to not only real-time beam steering but also multi-beam forming simultaneously. And they can cancel the beam at the specific direction. In this paper, we describe the implementation of sub-array type antenna hardware which can be applying DBF. Also we propose the modified amplitude aperture distribution for suppressing the side lobe level and explain the sub-array receiver design with amplitude tapering. It consists in making the amplitude weighting in 2 steps. In order to compare two weighting cases, we investigate the G/T performance for the array antenna. At the conclusion, we make a comparative study for the dynamic range of every sub-array receiver and present the hardware implementation that is more advantageous for sub-array alignment and calibration in DBF.

Evaluation of Contralateral Breast Surface Dose in FIF (Field In Field) Tangential Irradiation Technique for Patients Undergone Breast Conservative Surgery (보존적 유방절제 환자의 방사선치료 시 종속조사면 병합방법에 따른 반대편 유방의 표면선량평가)

  • Park, Byung-Moon;Bang, Dong-Wan;Bae, Yong-Ki;Lee, Jeong-Woo;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.401-406
    • /
    • 2008
  • The aim of this study is to evaluate contra-lateral breast (CLB) surface dose in Field-in-Field (FIF) technique for breast conserving surgery patients. For evaluation of surface dose in FIF technique, we have compared with other techniques, which were open fields (Open), metal wedge (MW), and enhanced dynamic wedge (EDW) techniques under same geometrical condition and prescribed dose. The three dimensional treatment planning system was used for dose optimization. For the verification of dose calculation, measurements using MOSFET detectors with Anderson Rando phantom were performed. The measured points for four different techniques were at the depth of 0cm (epidermis) and 0.5cm bolus (dermis), and spacing toward 2cm, 4cm, 6cm, 8cm, 10cm apart from the edge of tangential medial beam. The dose calculations were done in 0.25cm grid resolution by modified Batho method for inhomogeneity correction. In the planning results, the surface doses were differentiated in the range of $19.6{\sim}36.9%$, $33.2{\sim}138.2%$ for MW, $1.0{\sim}7.9%$, $1.6{\sim}37.4%$ for EDW, and for FIF at the depth of epidermis and dermis as compared to Open respectively. In the measurements, the surface doses were differentiated in the range of $11.1{\sim}71%$, $22.9{\sim}161%$ for MW, $4.1{\sim}15.5%$, $8.2{\sim}37.9%$ for EDW, and 4.9% for FIF at the depth of epidermis and dermis as compared to Open respectively. The surface doses were considered as underestimating in the planning calculation as compared to the measurement with MOSFET detectors. Was concluded as the lowest one among the techniques, even if it was compared with Open method. Our conclusion could be stated that the FIF technique could make the optimum dose distribution in Breast target, while effectively reduce the probability of secondary carcinogenesis due to undesirable scattered radiation to contra-lateral breast.

  • PDF

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

A Study for Operation Technique Plan of Low-Cost UAV Data Bus (저가형 무인항공기 DATA BUS 운용기술 방안 연구)

  • Gil, Hyun-Cheol;Ahn, Dong-Mhan;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.6
    • /
    • pp.1024-1031
    • /
    • 2012
  • In the past, the part of development of that is used for the military aviation target or reconnaissance is being extended to the range of application not only reconnaissance but also civilian industry as the introduction of the newest IT technology and the technical evolution. The Civilian low-cost UAV that is expected growth at the market of UAV in the world is accelerated to the extended applicability in the fields. However, The UAV study is recently focused on the Link and The Data bus because the main decision of the civilian UAV system configuration is not suitable to determinate the factory of price. In this paper is analysed the UAV data bus through the simulation in same condition both the CAN Bus which used the automobile industry and the MIL-STD-1553B which is used the aviation industry. As a comparison result, we identified that the CAN Bus of conventional configuration is possible to transmit the data without the need for a separate coupler equipment against the MIL-STD-1553B data. Thus, we identified that the CAN bus is capable to apply as a low-cost UAV internal data bus to optimize configuration and weight than 1553B.