• Title/Summary/Keyword: 면진

Search Result 315, Processing Time 0.023 seconds

Shaking Table Test of a Stainless Water Tank with Natural Rubber Bearing (천연고무받침이 설치된 스테인리스 물탱크의 진동대 실험)

  • Kim, Hu-Seung;Oh, Ju;Jung, Hie-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.52-58
    • /
    • 2016
  • Recently, interest in structural stability has increased due to earthquakes. Isolation systems can improve seismic ability without harming the functions and appearance of existing and new constructions, and they have established efficiency in foreign country that have experienced earthquakes. In this study, an isolation system is suggested using a natural rubber bearing (NRB) on a stainless water tank for stability assurance in an earthquake. A shaking table test was carried out to evaluate the seismic capacity of a non-isolated water tank and an isolated tank. Displacement meters in the water tank measured the behavior characteristics of the tanks, which were compared using artificial seismic waves of 0.154 g, 0.231 g, 0.341 g, and 0.348 g with water levels of 0.0 m, 1.5 m, and 2.5 m. At 2.5 m, a decrement effect was generally shown in the isolated water tank, and a bigger displacement occurred in the non-isolated water tank than in the isolated one at water levels of 0.0 m and 1.5 m. It is interpreted that the weight of different water levels affects the decrement effect. If seismic reinforcement is done, the isolated bearing should be designed while considering the fluid storage level.

Experimental Study of Friction Pendulum System to Improve the Seismic Capacity of Transformer (변압기의 내진성능 향상을 위한 마찰진자 면진장치의 시험 연구)

  • Jang, Jung-Bum;Kim, Jeong-Ki;Hwang, Kyeong-Min;Ham, Kyung-Won;Park, Jin-Wan;Lee, Chan-Wook
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.1-8
    • /
    • 2008
  • Friction pendulum system is developed to prevent the damage of transformer, which is the most important among the electric power facilities, due to the earthquake and its seismic capacity is verified through the shaking table test. The applicability of friction pendulum system is confirmed as test results of compressive capacity test and friction test. Especially, as a result of shaking table test with a large scale transformer model, friction pendulum system gives to the reduction of maximum response acceleration by 30% at anchorage of transformer and 59% at the top of porcelain bushing comparing with the existing anchorage type. In addition to the reduction of maximum response acceleration, natural frequency of transformer is shifted to long period due to the friction pendulum system. In case that friction pendulum system is applied to the transformer, the damage of transformer can be prevented effectively under the earthquake.

Seismic Design and Analysis of Seismically Isolated KALIMER Reactor Structures (면진된 KALIMER 원자로 구조물의 내진설계 및 지진해석)

  • 이형연
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.75-92
    • /
    • 1999
  • In this paper, the seismic analysis model for seismically isolated KALIMER reactor structures is developed and the modal analysis and the seismic time history analysis are carried out for seismic isolation and non-isolation cases. To check the seismic stress limit according to the ASME Code, the equivalent seismic stress analyses are preformed using the 3-D finite element model. From the seismic stress analysis, the seismic margins are calculated for structural members. The limit of seismic load is defined to show that the maximum input acceleration ensures the structural safety for seismic load. In comparison of seismic responses between seismic isolation and non-isolation cases, the seismic isolation design gives significantly reduced acceleration responses and relative displacements between structures. The seismic margin of KALIMER reactor structure is high enough to produce the limit seismic load 0.8g.

  • PDF

Seismic Response of Apartment Building with Base Isolation System Consisting of Sliding-type Bearing and Lend Rubber Bearing (LRB와 슬라이딩베어링을 혼용한 면진시스템을 적용한 아파트 건물의 지진 응답)

  • Chun, Young-Soo;Yoon, Young-Ho;Whang, Ki-Tea;Chang, Kug-Kwan
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.507-514
    • /
    • 2007
  • This paper summarizes the results of a research on the isolate effects and economical efficiencies of seismic isolation design compared with the existing earthquake-resistant design, and presents seismic performance of the base isolation system consisting of sliding-type bearing and lead rubber bearing (LRB) compared with that consisting of the LRB only. From the results of the research, it is verified that seismic isolation is very effective to mitigate the influence of earthquake on structures and it is possible to increase the serviceability due to decrease of the floor acceleration. Also, from the point of view of reduction of story acceleration and base shear, the base isolation system consisting of sliding-type bearing and LRB is more effective than that with LRB only. In respect of economical efficiency, special care should be taken in using this method since costs which have to be paid in proportin to increased performance are high.

Life-Cycle Analysis of Nuclear Power Plant with Seismic Isolation System (면진장치 적용을 고려한 원전구조물 생애주기 분석)

  • Kim, Sunyong;Lee, Hong-Pyo;Cho, Myung-Sug
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.6
    • /
    • pp.415-421
    • /
    • 2013
  • In order to extend the service life of a nuclear power plant(NPP) ensuring the structural safety, effective and efficient management of NPP considering structural deteriorations and various natural hazard risks has been treated as a significant tool(IAEA 1998). The systemic efforts is required to prevent the potential loss of NPPs resulting from the natural hazard including earthquakes, hurricane and flooding since the Fukushima accident. Earthquake risk of building structures can be mitigated through appropriate seismic isolation system installation. It has been known that a seismic isolation system can lead to reduction of the deleterious effect on ground motion induced by earthquakes, and structural safety can be improved. In this paper, the NPP life-cycle management is reviewed. Furthermore, effect of seismic isolation on the NPP life-cycle cost analysis with earthquake, and cost-benefit analysis in terms of life-cycle cost when applying the seismic isolation systems to NPP are introduced.

Investigation of Adaptability of Smart Base Isolation System for Spacial Structures in Regions of Low-to-Moderate Seismicity (중약진지역 대공간 구조물에 대한 스마트 면진시스템의 적용성 검토)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.4
    • /
    • pp.109-119
    • /
    • 2011
  • To date, a smart base isolation system has been developed in high seismicity region such as Japan, USA etc. Smart base isolation systems developed for structures in high seismicity region cannot directly applied to structures in regions of low-to-moderate seismicity such as Korea. Therefore, problems that occur by applying the smart base isolation system developed for the structures in high seismicity region to the structures in regions of low-to-moderate seismicity have been investigated in this study. To this end, a spacial arch structure was used as an example structure and MR dampers and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes were used for ground motions in regions of high and low-to-moderate seismicity. Based on numerical simulation results, it has been known that the capacity of smart base isolation system for the regions of low-to-moderate seismicity should be carefully designed because the base isolation effects of the smart base isolation system for high seismicity region is deteriorated when it is applied to the structures in regions of low-to-moderate seismicity.

Shaking Table Test of Isolated EDG Model (면진된 모형 비상디젤발전기의 지진응답 실험)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.33-42
    • /
    • 2007
  • In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

Construction of Design Table for Envelope Curve Analysis of Base Isolated Buildings (면진건물의 포락해석을 위한 설계용 도표 산정면진건물의 포락해석을 위한 설계용 도표 산정면진건물의 포락해석을 위한 설계용 도표 산정)

  • Lee, Hyun-Ho;Cheon, Yeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.2
    • /
    • pp.59-67
    • /
    • 2006
  • The aim of this study is to evaluate the design table for envelope curve analysis of base isolated buildings, which represent the period of base isolated buildings and the lateral displacement of base isolation devices. For the construction of design table, $V_E$ spectrum, which represents the energy, is developed instead of acceleration of seismic hazard. Based on the seismic coefficient of UBC 97, boundary period $T_G$ and maximum velocity response $V_0$ are proposed considering Korea seismic hazard. Using $T_G$ and $V_0$, finally, $V_E$ spectrum is developed for the four types of soil conditions. Base on the $V_E$ spectrum, design table for envelope curve analysis is also developed for soil types.

Study of Characteristics of Smart Base Isolation System with MR Damper for Regions of Low-to-Moderate Seismicity (중약진지역에 대한 MR 감쇠기로 구성된 스마트 면진시스템의 특성연구)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.325-336
    • /
    • 2012
  • Smart base isolation systems developed for structures in high seismic regions cannot be directly applied to structures in regions of low-to-moderate seismicity, such as Korea. Therefore, the problems that occur by applying the smart base isolation system for high seismic regions to the structures in regions of low-to-moderate seismicity have been investigated in this study. To this end, a five-story building is used as an example, and an MR damper and low damping elastomeric bearings were used to compose a smart base isolation system. Artificial earthquakes are simulated for ground motions in regions of high and low-to-moderate seismicity. Based on numerical simulation results, the MR damper capacity that can provide good control is quite different among regions of high and low-to-moderate seismicity. Moreover, it is noted that the properties of a smart base isolation system for the regions of low-to-moderate seismicity should be carefully designed because the base isolation effects of the smart base isolation system for high seismic regions deteriorate when it is applied to the structures in regions of low-to-moderate seismicity.