• 제목/요약/키워드: 면역건물기술

검색결과 5건 처리시간 0.019초

청사 건물의 Bio-Attack에 따른 미생물 오염원 확산 및 제어방안에 관한 연구 (A Study on the Microbial Contaminant Transport and Control Method According to Government Building Bio- Attack)

  • 이현우;최상곤;홍진관
    • 설비공학논문집
    • /
    • 제20권4호
    • /
    • pp.252-259
    • /
    • 2008
  • The purpose of this study is to estimate the movement of microbial contaminant caused by bio-attack using bio-agent such as bacillus anthracis for preventing contaminant diffusion. multizone simulation was carried out in the case of three types of bio-attack scenario in the government building. Simulation results show that severe contaminant diffusion is brought about in all cases of bio-attack scenario in one hour, though pollution boundaries have different mode according to bio-attack scenarios. Simulation results also show that immune building technology such as filter and UVGI technology gives us powerful alternatives to meet the emergent situation caused by unexpected bio-attack.

Bioviolence Agents에 따른 건물내 미생물오염원의 효율적인 제거방안에 관한 연구 (A Study on the Effective Removal Method of Microbial Contaminants in Building According to Bioviolence Agents)

  • 이현우;홍진관
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.881-890
    • /
    • 2010
  • As Influenza A virus(H1N1) has been spreading more rapidly around globe, the study on the airborne disease which is transimitted through the respiratory system is on the rise. In this study, the multizone simulation of the public building against bioviolence is performed in the case of unexpected spread of microbial contaminants, such as bioviolence agent, Influenza A, Smallpox, B. anthrax and transport and control characteristics of above three kinds of bioviolence agents are evaluted. Results suggest that Influenza A and Smallpox which has small mean diameter can be more removable than B. anthrax by using high UVGI grade condition and B. anthrax which has large mean diameter can be more removable than Influenza A and Smallpox by using high filter grade condition. Results also suggest that installing a combined air treatment system is more effective to reduce the damage and engineers will use immune building technology for removing the bioviolence agents effectively.

실내 미생물 안전을 위한 면역건물기술 인자들의 상호작용에 관한 연구 (A Study of factor analysis of immune building system for microbiological safety)

  • 최상곤;장성민
    • 대한안전경영과학회지
    • /
    • 제14권3호
    • /
    • pp.85-92
    • /
    • 2012
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program contam2.4. This model include immune building system(disinfection system) which is consist of dilution, Filter Technology and UVGI(ultra violet germicidal irrdiation). In this study experiments design method used for estimating interaction of HRV air change rate, UVGI air change rate and UVGI grade. Result show that HRV air change rate and UVGI air change rate is most influence factor for remove rate. also Interaction of HRV air change rate and UVGI air change rate is ost influence factor for remove rate.

건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구 (A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety)

  • 최상곤
    • 대한안전경영과학회지
    • /
    • 제11권4호
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.

사료 내 비테인 첨가 급여가 비육돈의 영양소 소화율 및 생리학적 변화에 미치는 영향 (Effects of supplementation of dietary betaine on apparent nutrient digestibility and physiological responses in finishing pigs)

  • 김기현;김광식;김두완;사수진;김영화
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.407-414
    • /
    • 2016
  • 본 연구는 사료 내 비테인의 첨가 급여 시 비육돈의 영양소 소화율 및 생리학적 반응을 조사하기 위하여 실시하였다. 평균 체중 $80.1{\pm}3.7kg$의 거세 숫퇘지 12두를 개별 대사케이지에 공시하였다. 시험사료는 비육돈의 영양소 요구량을 충족하는 시판사료를 기초 대조구 시험사료로 하였으며, 기초사료에 0.5%의 비테인을 첨가한 사료를 처리구 사료로 이용하였다. 시험디자인은 $2{\times}2$ Latin square 법으로 설계하여 각 Phase 당 7일간 순치기간과 7일간의 시험기간을 두었다. 분석에서 얻어진 결과들에 대하여 처리구간의 통계적 유의성은 student' t-test을 이용하여 검정하였다. 영양소 소화율을 조사한 결과, 비테인 첨가 급여에 의해 건물 및 단백질의 외관상 소화율이 통계적으로 유의하게 각각 1%와 1.3%가 개선되는 것으로 관찰되었다(p<0.05). 에너지 이용율을 조사한 결과에서도 에너지의 외관상 소화율이 82.3%에서 83.7%로 비테인 급여에 의해 증가되었으며(p<0.05), 이로 인하여 체내 에너지 retention도 약 6% 이상 (대조구 4,057 vs 처리구 4,314 kcal; p<0.01) 유의하게 증가되는 것으로 관찰되었다. 혈중 생화학 성분 및 스트레스 호르몬, 면역단백질, 전염증성 사이토카인을 분석한 결과에서는 비테인 급여에 의한 유의한 영향은 관찰되지 않았다. 요약하자면, 육성돈 사료 내 비테인의 첨가급여는 생리적으로 부정적인 영향 없이 영양소 소화율 및 에너지 이용성 개선에 유의한 효과를 가지며, 이것은 증체량 및 사료효율을 개선하여 생산성을 향상 시킬 수 있는 가능성을 시사한다.