A study on the disinfection performance of indoor microorganism using energy consumption analysis for indoor bio-safety (건물 재실자의 미생물 안전을 위한 면역건물 기술의 에너지 사용 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.4
    • /
    • pp.111-118
    • /
    • 2009
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program CONTAM2.4. This model include disinfection system which is consist of dilution, filtration, UVGI(ultra violet germicidal irradiation). It's energy consumption was also analyzed through the linked model of CONTAM and TRNSYS according to the combination of components. The comparison of total energy consumption through energy analysis revealed that adjusting the air change rate of the UVGI air sterilizer to maintain the same indoor microbe removal capability was more advantageous in terms of energy consumption.

A Study on the Microbial Contaminant Transport and Control Method According to Government Building Bio- Attack (청사 건물의 Bio-Attack에 따른 미생물 오염원 확산 및 제어방안에 관한 연구)

  • Lee, Hyun-Woo;Choi, Sang-Gon;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.252-259
    • /
    • 2008
  • The purpose of this study is to estimate the movement of microbial contaminant caused by bio-attack using bio-agent such as bacillus anthracis for preventing contaminant diffusion. multizone simulation was carried out in the case of three types of bio-attack scenario in the government building. Simulation results show that severe contaminant diffusion is brought about in all cases of bio-attack scenario in one hour, though pollution boundaries have different mode according to bio-attack scenarios. Simulation results also show that immune building technology such as filter and UVGI technology gives us powerful alternatives to meet the emergent situation caused by unexpected bio-attack.

A Study on the Diffusion and Removal of Airborne Microorganism Pollution in Multistoried Apartment by the Multi-Zone Simulation (멀티존 시뮬레이션에 의한 공동주택의 미생물 오염원 확산과 제거에 관한 연구)

  • Hong, Jin-Kwan;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.291-298
    • /
    • 2007
  • The purpose of this study is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs such as bacteria and fungus and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for immune building systems.

The study on the multizone modeling for preventing transmission of air borne contagion (실내 미생물오염 전파방지를 위한 멀티죤 모델링에 관한 연구)

  • Choi, Sang-Gon;Lee, Hyun-Woo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.429-435
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 which is developed by NIST is used for modeling the air disinfection system which is consist of dilution, filtration, ultra violet germicidal irradiation (UVGI) for removing the indoor microorganism such as bacteria and fungus. Developed models those protect occupants against indoor microorganism generated in our daily life are enable to use for immune building simulation tool. Also, results indicate that those models are enable to compute the real situation that is almost impossible of carrying out experiment and identify the disinfection rate with highly reliance. Results also suggest that engineers will use these models as a design tool for the immune building system.

  • PDF

A Study on the Effective Removal Method of Microbial Contaminants in Building According to Bioviolence Agents (Bioviolence Agents에 따른 건물내 미생물오염원의 효율적인 제거방안에 관한 연구)

  • Lee, Hyun-Woo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.881-890
    • /
    • 2010
  • As Influenza A virus(H1N1) has been spreading more rapidly around globe, the study on the airborne disease which is transimitted through the respiratory system is on the rise. In this study, the multizone simulation of the public building against bioviolence is performed in the case of unexpected spread of microbial contaminants, such as bioviolence agent, Influenza A, Smallpox, B. anthrax and transport and control characteristics of above three kinds of bioviolence agents are evaluted. Results suggest that Influenza A and Smallpox which has small mean diameter can be more removable than B. anthrax by using high UVGI grade condition and B. anthrax which has large mean diameter can be more removable than Influenza A and Smallpox by using high filter grade condition. Results also suggest that installing a combined air treatment system is more effective to reduce the damage and engineers will use immune building technology for removing the bioviolence agents effectively.

Changes in Abscisic Acid level During Seed Germination of Rice by Radioimmunoassay (방사면역측정법에 의한 수도종자발아중 Abscisic Acid 함량변동)

  • 황태익;임현옥;김용재;이민화
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.30 no.1
    • /
    • pp.53-62
    • /
    • 1985
  • A radioimmunoassay technique has been developed for the determination of abscisic acid (ABA) in crude extracts from germinating rice (Oryza sativa L.). By this method, the changes in ABA level of rice during germination was investigated. The ABA content in rice seeds was found to be 76.5ng/g dry weight in Dong-jin variety and 91.1ng/g dry weight in Sam-gang variety. A rapid decrease in ABA content of rice occurred during germination within 24 hours after seed imbition. The decreasing rate of ABA content during germination showed a significant direct proportion to the imbibition temperature and water-absorbing rate of rice. The decrease in ABA content during germination was found to be caused partly by an elution of ABA from the tissue to the imbibing fluid, and partly by a metabolic conversion of ABA to another compounds. The germination process of rice occurred only when the tissue ABA level decreased below a certain level, and the decreasing rate of ABA level during germination correlated with the ability for germination at low temperature of rice.

  • PDF

A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion (실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구)

  • Choi, Sang-Gon;Lee, Hyun-Woo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.

The study on the Performance of air sterilization of multistoried apartment by the multizone modeling (멀티죤 시뮬레이션에 의한 공동주택의 미생물 오염원제거 성능평가에 관한 연구)

  • Choi, Sang-Gon;Park, Kyung-Su;Yoon, Young-Soo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.319-324
    • /
    • 2006
  • The purpose of this study Is to evaluate the efficacy of multizone simulation that enables to grasp of details about microbial contaminant problem in an multistoried apartment. We used actual indoor test data to figure up microbial contaminant level as initial value for the multizone simulation and estimated the various effects of indoor occupant infected with germs and the performance of air sterilization by using multizone simulation in substitute for infeasible experimental approach. The results show that natural ventilation make ourselves generally useful for removing indoor microbial contaminants. The results also show that the performance of air sterilization reach the maximum in the case of using mechanical ventilation and UVGI air sterilizer. The conclusion is that this multizone simulation is useful tool for actual design method for Immune building systems.

  • PDF

삶은 곧 자연이다(Life is Nature) - 인류의 건강한 풍요로움을 지향하다 -

  • Lee, Gyeong-Hyeon
    • KOREAN POULTRY JOURNAL
    • /
    • v.40 no.12
    • /
    • pp.126-129
    • /
    • 2008
  • 경부고속도로 천안휴게소에 서면 도로 너머로 화려한 원색의 기다란 건물이 보인다. 장난감을 만드는 회사인가 싶을 정도로 알록달록한 이곳은 외관의 느낌과 달리, 면역체계 증진을 위한 사료첨가제와 AI 예방제, 다약제내성병원체(MDRP)치료제를 개발 판매하고 있으며, 각종 친환경 유기농 제품군을 생산, 판매하고 있는 친환경 바이오 전문 기업 (주)리스나(대표 이종화, 이혁기, 정태호)의 본사이다. 리스나(Liisna)는 'Life is Nature'의 약자로 '삶은 곧 자연이다. 생명의 원천은 자연이다. 생명과 자연은 하나다.' 라는 의미를 포함하고 있다. 리스나의 전신인 구 오보바이오는 2005년 단국대학교 내 창업센터에서 시작해 2007년 지금의 자리로 이전하였다. 그리고 순환적 발전 모델을 추구하고자 2008년 8월 '(주)리스나'로 사명과 CI를 변경했다. 사명과 CI 변경을 통해 '바이셀라 코리엔시스(Weissella koreensis)'를 기반으로 한 바이오 사업 부문과 유기농 사업 부문이 순환적으로 결합되어 친환경 바이오 전문기업으로서의 시너지 효과를 꾀하고 있다. 아울러 '인류의 건강한 행복을 지향하는 기업' 이라는 비전을 이루기 위해 노력하고 있다.

  • PDF

A Study of factor analysis of immune building system for microbiological safety (실내 미생물 안전을 위한 면역건물기술 인자들의 상호작용에 관한 연구)

  • Choi, Sang-Gon;Jang, Sung-Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.85-92
    • /
    • 2012
  • In this study the real situation of apartment house in seoul is reproduced with multi-zone modeling program contam2.4. This model include immune building system(disinfection system) which is consist of dilution, Filter Technology and UVGI(ultra violet germicidal irrdiation). In this study experiments design method used for estimating interaction of HRV air change rate, UVGI air change rate and UVGI grade. Result show that HRV air change rate and UVGI air change rate is most influence factor for remove rate. also Interaction of HRV air change rate and UVGI air change rate is ost influence factor for remove rate.