• Title/Summary/Keyword: 맥진(脈診)

Search Result 111, Processing Time 0.044 seconds

The Diagnostic Values of Ryodoraku and Pulse Analysis for Respiratory Disease Patients (호흡기계 환자에 대한 양도락 ${\cdot}$ 맥진검사의 진단적 가치)

  • Hwang, Joon-Ho;Jung, Seung-Yeon;Jung, Sung-Ki
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.3
    • /
    • pp.560-569
    • /
    • 2007
  • Objectives : Ryodoraku is a physiological function test using electric current, and is closely related to skin sympathetic tone. Pulse analysis is known to reflect cardiovascular reactivity. There has been no report on the correlation between ryodoraku and pulse analysis in respiratory diseases. The present study examined the diagnostic values of ryodoraku and pulse analysis for respiratory disease patients Methods : For this study, we conducted ryodoraku and pulse analysis in 103 people including 79 respiratory disease outpatients who visited the $5^{th}$ Internal Department of the Oriental Medicine Hospital of Kyung Hee University during the period from January 1, 2003 to July 25, 2006, and 24 volunteers who did not have any respiratory symptoms or disease history. The respiratory disease patients were divided into five sub-groups according to their symptom: cough-sputum group, wheezing-dyspnea group ' nasal symptoms group. cold-prone group, and fatigue prone group. We compared the disease groups with the control group in six items as follows : mean ryodoraku, mean H1, mean elastic index, the percentage of those with mean ryodoraku below $40{\mu}A$, the percentage of those with HI beyond the physiological range, and the ratio of left : right of elastic index Results and Conclusions : Ryodoraku and pulse analysis were found to have a high value as quantitative diagnosis tools reflecting individuals' weakness and firmness. The results of this research suggest that ryodoraku and pulse analysis have value as tools for diagnosing respiratory diseases.

  • PDF

Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet (영구자석과 홀소자를 이용한 무선 집게형 맥진기 특성 연구)

  • Yoon, Woo-Sung;Ji, Jong-Ok;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.179-185
    • /
    • 2014
  • The existing USB connection type of the clip-type pulsmeter equipped with a Hall sensor and a permanent magnet does not have any error or malfunction to measure the pulse wave. The property of the wireless networking system communicating the pulse wave data through the wireless LAN communication by combination USB with Ethernet and Ethernet to Wi-Fi converting system instead of existing USB connection method was investigated. There are exited that the patient needs to stay at close site of the desktop PC without USB connector and the wireless transfer and receiver networking system has pulse wave measurement SW to receive the pulse wave data. Thus it is expected that the study becomes helpful to measure and transfer the exact pulse wave of the patient in a comfortable pose at close range.

Groping for the Direction of Development from the Comparison of Traditional Medicine between Korea and Vietnam (한국과 베트남의 전통의학 현황 비교를 통한 발전 방향 모색)

  • Kwon, Ji-Hye;Lee, Si-Woo;Yoo, Jong-Hyang
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.2
    • /
    • pp.370-376
    • /
    • 2015
  • The aim of this study was to survey the recognition and utilization of traditional medicine among the clinical doctors who working at traditional medicine hospital in Vietnam. The survey was conducted for 3month from September to November, 2012. As a result, the highest recognized traditional medicine was acupuncture(91.4%) and herbal medicine(86.1%). Almost of respondents had ever used acupuncture(99.4%), massage or acupressure(97.6%) and herbal medicine(95.3%) in daily clinical practice. And commonly treated health problem was neurological and psychological disease(23.5%). The most used diagnostic methods were tongue diagnosis and pulse diagnosis(97.6%). This survey will help to explore the point of contact between the traditional medicine of Vietnam and Korea. This survey results could be used as basic materials to actively approach traditional medical markets through international exchange and cooperation in the future.

Compare correlation differnces in blood in blood flow velocity parameters and blood flow velocity the radial artery and a piece of paper as a maker (요골동맥과 첨지를 이용하여 혈류속도 파라미터와 혈류속도 사이의 상관관계 비교)

  • Heo, Sun-Oh;Jeong, Jin-Hyeong;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • In this study, regressive models were employed to predict the blood velocity by using independent variables which measured by 3 sensors, such as electrocardiogram (ECG), photo-plethysmogram (PPG), pulse diagnosis sensor, without ultrasound device at high cost. In experiment, the high predictable model was induced to estimate the blood velocity correctly by comparing correlation values and significance probabilities between independent variables and blood velocities. Results showed that the model induced by two or three independent variables had a higher predictability than those by a single independent variable.

Classification method of chronic gastritis by modeling of pulse signal (맥파 모델링을 통한 만성위염 분류 기법)

  • Choi, Sang-Ho;Shin, Ki-Young;Shin, Jitae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.144-151
    • /
    • 2012
  • Chronic gastritis is the disease that is occuring in one in every 10 persons in Korea. In western medicine, endoscopy is needed to diagnose chronic gastritis, but it causes patients a pain and budget of expense. According to the TEM (Traditional Eastern Medicine), on the other hand, the 'Guan' position of the right wrist is related to a stomach. Thus we can diagnosis chronic gastritis by analyzing of pulse signal. However, pulse signal diagnosis is depended on oriental doctor's knowledge and experience. In this study, a systematic approach is proposed to analyze the computerized pulse signal. The pulse signals are firstly pre-processed, Gaussian model is adopted to fit the pulse signal, and then some related parameters are extracted from the model. Consequently, disease-sensitive parameters are selected by T-test and statistical difference. Finally, the selected parameters are entered into a Fuzzy C-Means (FCM) algorithm for classification. Classification results show that healthy persons and chronic gastritis patients are 95% and 87%, respectively.

The study of non-contact/non-invasive pulse analyzing system using Optical Coherence Tomography (OCT) for oriental pulse diagnosis (비접촉식 광생체단층촬영 기술을 이용한 맥진 연구 -맥의 빠르기, 크기 및 맥력을 중심으로-)

  • Na, Chang-Su;Youn, Dae-Hwan;Kim, Young-Sun;Lee, Chang-Ho;Jung, Woon-Sang;Kim, Jee-Hyun;Choi, Chan-Hun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.1-13
    • /
    • 2009
  • Objective: Optical Coherence Tomography (OCT) has emerged as an important optical imaging modality in non-invasive medical diagnostics. Hence, the aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by the non-contact/non-invasive pulse analyzing system using OCT on Chon(寸), Kwan(關), Chuk(尺). Method: Four korean medical doctors and the non-contact/non-invasive pulse analyzing system using OCT have measured the rapidity, the dimension, and the power of pulse waves of 25 volunteers. First, four korean medical doctors measured pulse waves of volunteers. During measuring, four doctors were separated from each other and so were volunteers. And then, the pulse waves of volunteers were measured by OCT. This was performed on the right Chon(寸), Kwan(關), Chuk(尺). Results: The study showed that the traditional method and the OCT based method had the 88% matches on the values of the slow and rapid pulse condition (遲數), 64% matches on the values of the small and big pulse condition(微細弱緩大[洪]), and 72% matches on the values of the weak and strong pulse condition(虛實). Conclusions: Based on the high similarities of the measurements of two approaches, we suggest that the OCT based pulse diagnosis method is useful for compensating the traditional method for the pulse diagnosis.

  • PDF

Pulse Diagnosis Algorithm and Digital Filter Design for Development of Digital Biomedical System (전자 맥진기 시스템 개발을 위한 맥파분석 알고리즘과 디지털 필터 설계)

  • Kim, Sang-Ho;Lim, Duk-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4473-4482
    • /
    • 2010
  • The examination of pulse, which is a typical palpation technique in the oriental medicine, has been used conventional analog system for discrimination of 28 pulses. However, the clipping phenomenon in the pulses, which used same feature extraction technique with ECG signals, has been occurred in analog system due to feature extraction method and over amplification from the input signals. It caused inaccurate to analyze the pulse signals. In this paper, we propose a digital filter design technique based on Prony's method for signal modeling and C-spline interpolation for feature extraction from pulse signal to compensate analog pulse detection system. In addition, we suggest a compensated electronic pulse detection system comprising new pulse analyzing algorithm and shape analysis technique for pulses, which were difficult to use in analog system. The feasibility for new proposed system has been confirmed comparing output signals between electronic pulse detection system having proposed filter design techniques with pulse analyzing algorithm and conventional analog system.

Development of pulse diagnosis possible simulator using the stepper motor pumps (스텝 모터 펌프를 이용한 맥진 가능한 시뮬레이터의 개발)

  • Ryu, Geun-Taek;Woo, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.915-918
    • /
    • 2016
  • Virtual testing devices are required due to rapid changes in the health care industry and the increase of the medical or nursing workforce. The importance of devices such as the simulator, blood vessels, and lab equipment for modeling blood flow to the heart is increasing too. In this study, we made heart pump by using a step motor and developed device which simulates arterial, venous blood pressure, and blood flow. We finally evaluated the function of proposed device. The proposed system is composed of the pump for simulating, the valve device to describe the resistance of the artery and vein, and a reducing device showing the characteristics of the venous system. We used BOXER pump for heart simulator and silicon tube for arterial and venous vessels, and designed a reducing device. We also used the pressure sensor to measure arterial blood pressure. For the evaluation of the proposed system, we selected a range of 50~100mmHg of the blood circuit 60 per minute and then compared the blood pressure of a person and the measured blood pressure.

  • PDF

A Study on Comparative Pulse Diagnosis of Renying Pulse(人迎脈) and Cunkou Pulse(寸口脈) (인영촌구비교맥진(人迎寸口比較脈診)에 관한 연구)

  • Yun, Chang-Yeol
    • Journal of Korean Medical classics
    • /
    • v.32 no.4
    • /
    • pp.35-46
    • /
    • 2019
  • Objectives : While Comparative Pulse Diagnosis of Renying pulse(人迎脈) and Cunkou pulse(寸口脈) is one of the three major pulse diagnostic methods in "Huangdineijing" along with Three Positions and Nine Indicators Pulse Diagnosis(三部九候脈診法) and Cunkou Pulse Diagnosis(寸口脈診法), it has died out in later periods. This study aims to examine this lost method. Methods : Annotations of "Huangdineijing" were examined along with descriptions of the author's own experience. Results & Conclusions : Renying is the Renying(人迎) point from the Stomach Channel(ST), while Cunkou is the Taiyuan(太淵) point from the Lung Channel(LU). These two points are compared in order to determine the deficiency and excess of the Zangfu(臟腑). Normal pulses(平脈) are Soft(軟脈) or Moderate(緩脈), while Stirred pulses(躁脈) are Stringy(弦脈), Tight(緊脈), Slippery(滑脈) or Long(長脈). If the Renying is once active where Shaoyang pulse is active, purge the Gallbladder and supplement the Liver. If there is Stirred pulse, purge the Triple Burner and supplement the Pericardium. If the Renying is twice active where Taiyang pulse is active, purge the Bladder and supplement the Kidney. If there is Stirred pulse, purge the Small Intestine and supplement the Heart. If the Renying is three times active, where Yangming pulse is active, purge the Stomach and supplement the Spleen. If there is Stirred pulse, purge the Large Intestine and supplement the Lung. If the Cunkou is once active where the Jueyin pulse is active, purge the Liver and supplement the Gallbladder. If there is Stirred pulse, purge the Pericardium and supplement the Triple Energizer. If the Cunkou is twice active where the Shaoyin pulse is active, purge the Kidney and supplement the Bladder. If there is stirred pulse, purge the Heart and supplement the Small Intestine. If the Cunkou is three times active where the Taiyin pulse is active, purge the Stomach and supplement the Spleen. If there is Stirred pulse, purge the Lung and supplement the Large Intestine.

Disease Prediction System based on WEB (WEB 기반 질병 예측 시스템)

  • Hong, YouSik;Han, Y.H.;Lee, W.B.
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.125-132
    • /
    • 2022
  • The Ministry of Environment recently analyzed the output data of 10 fine dust measuring stations and, as a result, announced that about 60% had an error that the existing atmospheric measurement concentration was higher. In order to accurately predict fine dust, the wind direction and measurement position must be corrected. In this paper, in order to solve these problems, fuzzy rules are used to solve these problems. In addition, in order to calculate the fine particulate sensation index actually felt by pedestrians on the street, a computer simulation experiment was conducted to calculate the fine particulate sensation index in consideration of weather conditions, temperature conditions, humidity conditions, and wind conditions.