• Title/Summary/Keyword: 맥동 유동

Search Result 148, Processing Time 0.03 seconds

A Study on Flow Characteristics in Muffler for 125cc Grade Motorcycle (125cc급 모터사이클용 머플러 내부 유동특성에 관한 연구)

  • Yi, Chung-Seob;Jeong, In-Guk;Yun, Ji-Hun;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.2
    • /
    • pp.196-201
    • /
    • 2012
  • This study represents numerical study on the thermal and fluid flow characteristics of exhaust gas in a motorcycle muffler. The engine generates 125cc of displacement. Numerical analysis with computational fluid dynamics(CFD) was carried out to investigate the exhaust gas that flow into a motorcycle muffler. The STAR-CD S/W used to analyze three dimensional steady state and transient in a muffler. The Navier-Stokes Equation is solved with SAMPLE and PISO method in cartesian coordinates system. As the numerical result, it could be confirmed pulsating pressure generated from inlet of muffler become closer to the atmospheric pressure through baffle. Also the numerical result was almost identical to experimental result and, through the comparison, the reliability of numerical result was confirmed.

Development of CAE tool for reducing vibration of pipe-mount system conveying fluid (유동이 있는 배관-마운트 계의 진동저감설계 CAE Tool개발)

  • Lee, Seong-Hyeon;Jeon, Su-Hong;Jeong, Weui-Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.472-473
    • /
    • 2008
  • In this research, the finite element model is formulated taking into consideration of the effects of the fluid flow in a pipe. The characteristic of vibration is presented using mass, damping and stiffness matrix in the finite element equation of this pipe system. The displacement distribution of pipe system caused by fluid force is discussed. The method for optimizing the location of mount and the value of mount stiffness to reduce the vibration of pipe system is introduced.

  • PDF

In vitro study of downstream flow passing through heart valve prostheses (인공 심장판막 하류 유동의 in vitro 연구)

  • Kim Hyoung-Bum;Lanning Craig
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • The left ventricular filling flow is now considered as an indicator which can be used for early diagnosing of cardiovascular diseases. Because the understanding of left ventricular flow physics is critical for this purpose, the downstream flow characteristics of the artificial heart valve are investigated using particle image velocimetry (PIV) method. In this study, we investigated the wake characteristics of flows passing through three different artificial valves (St.Jude medical bileaflet mechanical valve. Bjork-Shiley monostrut mechanical valve and St.Jude medical Biocor bio valve). The downstream flow field has remarkably altered according to the different valves. SJM MHV has the flow field similar to the pulsating circular jet and BS MHV has oblique pulsating jet. SJM BHV shows the similar flow field of clinical data of normal heart.

  • PDF

Effects of Frequency Characteristics of High Frequency-Hydraulic System for the Changes of Accumulators (축압기의 변화가 고주파 유압시스템의 주파수 특성에 미치는 영향)

  • Roh, Hyung-Woon;Kim, Jae-Soo;Park, Nam-Eun;Kim, Yang-Soo;Jeon, Seung-Bae;Na, Hong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1936-1941
    • /
    • 2003
  • Characteristics of the high frequency and pulsatile flow investigated experimentally to understand the flow phenomena in the hydraulic system. In the study, I axis fatigue tester which are widely used for automobile filed are selected. 4 Pressure transducer, amplifier, A/D convertor are used to analyse and to obtain the pulsatle pressure waveform with high frequencies in hydraulic system. Matlab are used. to analyse the characteristics of frequency. Variation of pump input pressure and actuator acceleration frequency, pressure wave are measured with or without accumulators. For with accumulator, frequency amplitude of pressure are very lower than those of without accumulator due to absorbing function of accumulator. As the actuator acceleration frequency increased, effect of accumulator are very important to decrease the pulsatile pressure waveform with high frequencies.

  • PDF

Flow Characteristics due to Cutoff angle of Turbo-Fan for Industries (산업용 Turbo형 송풍기의 Cutoff 각도에 따른 유동특성)

  • Yun, Ji-Hun;Jeong, In-Guk;Yi, Chung-Seob;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.5
    • /
    • pp.91-96
    • /
    • 2011
  • This study aims to analyze the flow characteristics of turbo-fan which is applied to the industrial field. Numerical analysis has been carried out to investigate the pulsation behavior of exhaust air flown out turbo fan by rotating impeller with constant speed. Moving mesh technique is proved as time-accurate solution for the flow inside impeller. As numerical results come within the error range of 1% by comparing with theoretical results, the numerical analysis can be verified. Cutoff angle has large influence on the amplitude of pulsation and the least pulsation of flow can be generated by the cutoff angle of $20^{\circ}$.

A Study on Mathematical Modeling of Forcing Function for the Piping Vibration of Petrochemical Plant Design (플랜트 설계 시 배관진동을 유발하는 가진 함수의 수학적 모델링)

  • 민선규;최명진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.591-595
    • /
    • 1997
  • In analysis of piping vibration of petrochemical plant, the forcing functions mainly depend upon the equipment working mechanism and vibration resources in the piping systems. In general, harmonic function is used for the system with rotary equipments. Mechanical driving frequencies, wave functions, and response spectrum are used for reciprocating compressors, surge vibration of long transfer piping, and seismic/wind vibration, respectively. In this study, for the spray injection case inside the pipe, forcing function was modeled, in which two different fluids are distributed uniformly. To confirm the results, the scheme used for the forcing function was applied for real piping system. The vibration mode of the real system was consistent with the 4th mode obtained by simulation using the forcing function formulated in this study.

  • PDF

Experimental research on blood sucking phenomena of a female mosquito (암모기 흡혈과정에 대한 실험적 연구)

  • Kim, Bo-Heum;Lee, Jung-Yeop;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1475-1478
    • /
    • 2008
  • We have investigated the blood sucking phenomena of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism and eventually to develop a bio-mimic technology that can be used to resolve the problem encountered in the transport of infinitesimal biological fluids in various bio-chips and microchips. At first, the consecutive velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) system employed with a high-speed camera. The velocity signals of the blood-sucking flow in the proboscis represent a periodic pulsatile flow pattern and spectral analysis on the velocity waveform shows a clear peak at 6.1 Hz.

  • PDF

Two-dimensional numerical simulation of volumetric gear pump flow (회전용적형 기어펌프 유동의 2차원 수치해석)

  • Lee, Jung-Ho;Park, Jong-Won;Kim, Tae-Goo;Lee, Sang-Wook
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.17-21
    • /
    • 2010
  • A volumetric gear pump is often used in extensive industrial applications to provide both high pressure and sufficiently high flow rate by physical displacement of finite volume of fluid with each revolution. To better understand the unsteady flow characteristics within the pump, numerical simulations were conducted by using moving dynamic meshing (MDM) techniques in commercially available CFD software, FLUENT. The effects of rotor clearance size and rotational speed of rotor on the flow characteristics, specially the temporal variation of velocity and pressure field, which is a main source of flow noise, was investigated. The results showed that significant reverse flow is developed in the rotor clearance and that its size is one of the most important factors affecting flow characteristics and pressure pulsation.

Vibration and Stress Analysis for Reactor Vessel Internals of Advanced Power Reactor 1400 due to Pulsation of Reactor Coolant Pump (원자로냉각재펌프 맥동에 대한 APR1400 원자로내부구조물의 진동 및 응력 해석)

  • Kim, Kyu-Hyung;Ko, Do-Young;Kim, Sung-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.221-226
    • /
    • 2011
  • The structural integrity of APR1400 reactor vessel internals has been being assessed referring the US Nuclear Regulatory Commission regulatory guide 1.20 comprehensive vibration assessment program. The program is composed of a vibration and stress analysis, a limited vibration measurement, and an inspection. This paper covers the vibration and stress analysis on the reactor vessel internals due to the pulsation of reactor coolant pump. 3-dimensional models to calculate the hydraulic loads and structural responses were built and the pressure distributions and the structural responses were predicted using ANSYS. The peak stress of the reactor vessel internals is much lower than the acceptance limit.

  • PDF

Numerical Analysis for Linear and Nonlinear Attenuation Characteristics of Exhaust Silencer Systems (배기 소음기의 선형 및 비선형 감쇄 특성에 대한 수치해석)

  • 김종태;김용모;맹주성;류명석;구영곤
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.4
    • /
    • pp.179-189
    • /
    • 1996
  • An unstructured grid finite-volume method has been applied to predict the linear and nonlinear attenuation characteristics of the expansion chamber silencer system. In order to achieve a grid flexibility and a solution adaptation for geometrically silencer system. In order to achieve a grid flexibility and a solution adaptation for geometrically complex flow regions associated with the actual silencers, the unstructured mesh algorithm in context with the node-centered finite volume method has been employed. The present numerical model has been validated by comparison with the analytical solutions and the experimental data for the acoustic field of the concentric expansion chamber with and without pulsating flows, as well as the axisymmetric blast flowfield with open end. Effects of the chamber geometry on the nonlinear wave attenuation characteristics is discussed in detail.

  • PDF