• Title/Summary/Keyword: 망막전위도 기록

Search Result 5, Processing Time 0.016 seconds

Waveform Sorting of Rabbit Retinal Ganglion Cell Activity Recorded with Multielectrode Array (다채널전극으로 기록한 토끼 망막신경절세포의 활동전위 파형 구분)

  • Jin Gye Hwan;Lee Tae Soo;Goo Yang Sook
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.148-154
    • /
    • 2005
  • Since the output of retina for visual stimulus is carried by neurons of very diverse functional properties, it is not adequate to use conventional single electrode for recording the retinal action potential. For this purpose, we used newly developed multichannel recording system for monitoring the simultaneous electrical activities of many neurons in a functioning piece of retina. Retinal action potentials are recorded with an extra-cellular planar array of 60 microelectrodes. In studying the collective activity of the ganglion cell population it is essential to recognize basic functional distinctions between individual neurons. Therefore, it is necessary to detect and to classify the action potential of each ganglion cell out of mixed signal. We programmed M-files with MATLAB for this sorting process. This processing is mandatory for further analysis, e.g. poststimulus time histogram (PSTH), auto-correlogram, and cross-correlogram. We established MATLAB based protocol for waveform classification and verified that this approach was effective as an initial spike sorting method.

  • PDF

PCA­based Waveform Classification of Rabbit Retinal Ganglion Cell Activity (주성분분석을 이용한 토끼 망막 신경절세포의 활동전위 파형 분류)

  • 진계환;조현숙;이태수;구용숙
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.211-217
    • /
    • 2003
  • The Principal component analysis (PCA) is a well-known data analysis method that is useful in linear feature extraction and data compression. The PCA is a linear transformation that applies an orthogonal rotation to the original data, so as to maximize the retained variance. PCA is a classical technique for obtaining an optimal overall mapping of linearly dependent patterns of correlation between variables (e.g. neurons). PCA provides, in the mean-squared error sense, an optimal linear mapping of the signals which are spread across a group of variables. These signals are concentrated into the first few components, while the noise, i.e. variance which is uncorrelated across variables, is sequestered in the remaining components. PCA has been used extensively to resolve temporal patterns in neurophysiological recordings. Because the retinal signal is stochastic process, PCA can be used to identify the retinal spikes. With excised rabbit eye, retina was isolated. A piece of retina was attached with the ganglion cell side to the surface of the microelectrode array (MEA). The MEA consisted of glass plate with 60 substrate integrated and insulated golden connection lanes terminating in an 8${\times}$8 array (spacing 200 $\mu$m, electrode diameter 30 $\mu$m) in the center of the plate. The MEA 60 system was used for the recording of retinal ganglion cell activity. The action potentials of each channel were sorted by off­line analysis tool. Spikes were detected with a threshold criterion and sorted according to their principal component composition. The first (PC1) and second principal component values (PC2) were calculated using all the waveforms of the each channel and all n time points in the waveform, where several clusters could be separated clearly in two dimension. We verified that PCA-based waveform detection was effective as an initial approach for spike sorting method.

  • PDF

Increase of Visual sensitivity by Zinc, Taurine, and Hypothermic-effect in Bullfrog's Eye (황소개구리 안구에서의 아연, 타우린, 저온효과에 의한 시각 감수성 증진)

  • Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.23-33
    • /
    • 2007
  • It has been reported high concentrations of zinc and taurine in ocular tissue, especially the retina-choroid, and the presence of physiological levels of zinc and taurine in these tissues seem essential for their normal function. In addition, several studies have reported temperature as another effector to the visual sensitivity. But, in spite of many studies, there are still remained many questions about their function and correlation in visual adaptation system. The purpose of present study was to clarify these points using electroretinogram(ERG) recording and absorption spectra scanning, before and after zinc and taurine treatments and hypothermic-effect in bullfrog(Rana catesbeiana) which is one of the poikilothermal animal. The optimal zinc concentration used in this study was determined $10^{-4}M$ while the optimal taurine concentration was 10-5 M, and temperature change for hypothermic-effect went through '$25^{\circ}C {\rightarrow}0^{\circ}C{\rightarrow}25^{\circ}C$'. In ERG recording, it is obtained that dark-adapted threshold became elevated and b-wave amplitudes was increased with zinc and taurine treatment and hypothermic-effect. In absorption spectra scanning, there is distinct absorbance increment over the whole spectral range(400~750 nm) after zinc and taurine treatment and hypothermic-effect. Furthermore there are some synergism effects between zinc and taurine as well as between zinc and hypothermic-effect as a result of co-treatment, respectively.

  • PDF

Reconstruction of Receptive Field of Retinal Ganglion Cell Using Matlab (Matlab을 이용한 망막신경절세포 감수야 구성)

  • Ye, Jang-Hee;Jin, Gye-Hwan;Goo, Yong-Sook
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.260-267
    • /
    • 2006
  • A retinal ganglion cell's receptive field is defined as that region on the retinal surface In which a light stimulus will produce a response. A retinal ganglion cell peers out at a small patch of the visual scene through its receptive field and encodes local features with action potentials that pass through the optic nerve to higher centers. Therefore, defining the receptive field of a retinal ganglion cell is essential to understand the electrical characteristics of a ganglion cell. Distribution of receptive fields over retinal surface provides us an Insight how the retinal ganglion cell processes the visual scene. In this paper, we provide the details how to reconstruct the receptive field of a retinal ganglion cell. We recorded the ganglion cell's action potential with multielectrode array when the random checkerboard stimulus was applied. After classifying the retinal waveform Into ON-cell, OFF-cell, ON/OFF-cell, we reconstructed the receptive field of retinal ganglion cell with Matlab. Here, we show the receptive fields of ON-cell and OFF-cell.

  • PDF

Feasibility of Optoelectronic Neural Stimulation Shown in Sciatic Nerve of Rats (흰쥐의 좌골 신경 자극을 통한 광전 자극의 가능성에 대한 연구)

  • Kim Eui tae;Oh Seung jae;Baac Hyoung won;Kim Sung june
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.611-615
    • /
    • 2004
  • A neural prostheses can be designed to permit stimulation of specific sites in the nervous system to restore their functions, lost due to disease or trauma. This study focuses on the feasibility of optoelecronic stimulation into nervous system. Optoelectronic stimulation supplies, power and signal into the implanted optical detector inside the body by optics. It can be effective strategy especially on the retinal prosthesis, because it enables the non-invasive connection between the external source and internal detector through natural optical window 'eye'. Therefore, we designed an effective neural stimulating setup by optically based stimulation. Stimulating on the sciatic nerve of a rat with proper depth probe through optical stimulation needs higher ratio of current spreading through the neural surface, because of high impedance of neural interface. To increase the insertion current spreading into the neuron, we used a parallel low resistance compared to load resistance organic interface and calculated the optimized outer parallel resistance for maximum insertion current with the assumption of limited current by photodiode. Optimized outer parallel resistance was at a range of 500Ω-700Ω and a current was at a level between 580uA and 650uA. Stimulating current efficiency from initial photodiode induced current was between 47.5 and 59.7%. Various amplitude and frequency of the optical stimulation on the sciatic nerve showed the reliable visual tremble, and the action potential was also recorded near the stimulating area. These result demonstrate that optoelectronic stimulation with no bias can be applied to the retinal prosthesis and other neuroprosthetic area.