• Title/Summary/Keyword: 마찰진자 베어링

Search Result 14, Processing Time 0.021 seconds

A study on the characteristics of friction pendulum isolation bearings (마찰진자형 면진베어링의 특성 연구)

  • 김영중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.407-414
    • /
    • 2000
  • The friction pendulum type seismic isolation system (FPS) has been developed to provide a simple and effective way to achieve earthquake resistance for buildings . The major advantages are: the isolation frequency can be easily achieved by designing a curvature of the surface and does not depend on the supported weight of a structure. The function of carrying vertical load is separated to the function of providing horizontal stiffness. Next the friction provides sufficient energy dissipation to protect the structure from earthquake response and resistance to the weak external disturbances such as wind load and ground vibrations due to traffic. In this paper, the friction coefficients are evaluated from number of experiments on the FPS test specimens. The relations between friction coefficient and the test waveform, velocity, and pressure are reviewed and further works are discussed.

  • PDF

Experimental Study on Floor Isolation of Main Control Room of Nuclear Power Plant using FPS(Friction Pendulum System) (마찰진자베어링(FPS) 면진시스템을 적용한 원전주제어실의 진동대 실험)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.445-452
    • /
    • 2005
  • The seismic characteristics with Friction Pendulum System have been studied using a shaking table system. In this study, we made two kind of floor system (Type I, Type II) and several seismic tests with and without isolation system were conducted to evaluate floor isolation effectiveness of Friction Pendulum System. Both type have showed large reduction effectiveness in acceleration, response spectra but Type II have showed lower acceleration and lower first mode in response spectra, compared to type I. On the basis of test results and consideration of application, it is found that type II is more suitable for floor model of main control room of Nuclear Power Plant.

  • PDF

Seismic Design for Application of LNG Storage Tank Isolation System (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Hyun-Jae;Kim, Nam-Sik;Kim, Jae-Min;Yang, Seong-Yeong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • The demand of natural gas is gradually increasing as a clean fuel in the world. Therefore, LNG storage tanks and related facilities of the importance of leading a community-based facility have emerged. The seismic design of LNG storage tank including seismic analysis have been developed steadily. But, the seismic analysis and design techniques for LNG storage tanks are lacking, in Korea. Consequently, it is necessary to develop an analysis model that LNG storage tanks in isolation system can describe the behavior. Further, LNG storage tank capable of ensuring safety and economy, it is necessary to develop design techniques. The studies have suggested seismic design procedures of LNG storage tanks with isolation system including triple-FPB and idealized complex hysteresis model of triple-FPB.

Seismic design for application of LNG storage tank isolation system (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Jae-Hyun;Yang, Seong-Yeong;Kim, Nam-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.132-138
    • /
    • 2013
  • Natural gas as a clean fuel of the world demand for the trend is gradually increasing demand for clean energy in the country and there is growing interest. Therefore, LNG storage tanks and related facilities in the country of the importance of leading a community-based facility has emerged. So common sense that an earthquake with a seismic isolation device LNG storage tank similar to the actual behavior of the analytical model which can describe the development and construction of storage tanks to enhance the safety and economic design techniques need to be developed. In this study, a base isolation system, seismic analysis procedure of LNG storage tanks, and Triple-FPB developed a mathematical model of the present crystallized and complexity factors to the sum over histories model simplifies the complex behavior of the LNG storage tank with base isolation system how to interpret the seismic isolation is proposed.

  • PDF