• Title/Summary/Keyword: 마이크로 소수력

Search Result 12, Processing Time 0.031 seconds

A Scheme on Energy Efficiency Through the Convergence of Micro-grid and Small Hydro Energy (마이크로그리드와 소수력 에너지의 융합을 통한 에너지 효율화 기법)

  • Kang, Bo-Seon;Lee, Keun-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • As smart grid techniques developed, public attention is concentrating on energy efficiency. So it is necessary to study on new renewable energy in order to manage the energy within micro grid consisting smart grid. Among them, small hydro energy has the advantage of being installable anywhere depending the amount of water used by the users within micro grid. This study examines if the measured value is appropriate for small hydro power generation by measuring generation quantity and operation rate of generator based on the sewage flow used by apartments and multi-unit dwellings where those users live. Some appropriate apartments and multi-unit dwellings generate electricity with small hydro generator using sewage as potential energy. This study intends to suggest more effective management by introducing energy management system and electricity storage device of micro grid.

Experimental Study of Micro hydropower with Vortex Generation at Lower Head Water (저낙차에서 와류발생부를 구비한 마이크로 소수력에 관한 실험 연구)

  • Choi, In-Ho;Kim, Jong-Woo;Chung, Gi-Soo
    • Journal of Wetlands Research
    • /
    • v.22 no.2
    • /
    • pp.121-129
    • /
    • 2020
  • This paper described a laboratory investigation of micro hydropower at lower head water in a free vortex flow. The vortex height, turbine rotation and torque for straight blade with inner curved edge, twisted blade and curved blade were investigated at the flow rate of 0.0069 ㎥/s in the inlet channel. The results showed that the optimum vortex strength occurred within the range of the diameter of basin to the outlet diameter ratios of 0.17~18.5. The power output and efficiency of straight blade were higher as compared to other blades. The highest amount of generated energy was 12.33 W, the torque was 0.91 N·m and the highest efficiency by considering effective head was 29.5 %, whereas the highest efficiency by considering vortex height was 80.5 % at the rotational speed of 132 rpm. The water vortex velocity of straight blade was about 2.8 times larger than the mean velocity in the inlet channel.

Design of Floating Point Adder and Verification through PCI Interface (부동 소수점 가산기 모듈의 설계와 PCI 인터페이스를 통한 검증)

  • Jung Myung-Su;Sonh Seung-Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.886-889
    • /
    • 2006
  • 수치연산 보조프로세서로도 알려져 있는 부동 소수점 연산장치(FPU)는 컴퓨터가 사용하는 기본 마이크로프로세서보다 더 빠르게 숫자를 다를 수 있는 특별한 회로 설계 또는 마이크로프로세서를 말한다. FPU는 전적으로 대형 수학적 연산에만 초점을 맞춘 특별한 명령 셋을 가지고 있어서 그렇게 빠르게 계산을 수행할 수 있는 것이다. FPU는 오늘날의 거의 모든 PC에 장착되고 있지만, 실은 그것은 그래픽 이미지 처리나 표현 등과 같은 특별할 일을 수행할 때에 필요하다. 초창기 컴퓨터 회사들은 각기 다른 연산방식을 사용했다. 이에 따라 연산결과가 컴퓨터마다 다른 문제점을 해결하기 위해 IEEE에서는 부동 소수점에 대한 표준안을 제안하였다. 이 표준안은 IEEE Standard 754 이며, 오늘날 인텔 CPU 기반의 PC, 매킨토시 및 대부분의 유닉스 플랫폼에서 컴퓨터 상의 실수를 표현하기 위해 사용하는 가장 일반적인 표현 방식으로 발전하였다. 본 논문에서는 부동 소수점 표준안 중 32-bit 단일 정밀도 부동 소수점 가산기를 VHDL로 구현하여 FPGA칩으로 다운하고 PCI 인터페이스를 통해 Visual C++로 데이터의 입출력을 검증하였다.

  • PDF

CFD Performance analysis of Micro Tubular-type hydro turbine by blade shape (블레이드 형상 변화에 따른 마이크로 튜블러 수차의 CFD 성능해석)

  • Park, Ji-Hoon;Hwang, Young-Cheol;Mo, Jang-Oh;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.206.1-206.1
    • /
    • 2011
  • Recently, various developments in the area of small hydropower have being made and small hydro turbines are suitable for domestic use because it is a clean and renewable energy source. A small hydropower generator produces power by using the different water pressure levels in pipe lines and energy which was initially wasted by use of a reducing valve at the end of the pipeline is instead collected by a tubular-type hydro turbine in the generator. In this study, in order to acquire the performance of tubular-type hydro turbine applied, the output power, head, efficiency characteristics due to the different guide vane and runner vane angle are examined in detail. Moreover, influences of pressure and velocity distributions with the variation of guide vane and runner vane angle on turbine performance are investigated by using a commercial CFD code.

  • PDF

A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant (정수장 마이크로 소수력 발전기 적용에 대한 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

CFD Analysis of a Counter-rotating Tubular Type Micro-Turbine with Diffuser (디퓨져를 이용한 튜블러형 상반전 수차의 CFD 성능해석)

  • Lee, Nakjoong;Park, Jihoon;Hwang, Young-Ho;Kim, Youtaek;Lee, Youngho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.205.2-205.2
    • /
    • 2011
  • Micro hydraulic turbines take a growing interest because of its small and simple structure as well as high possibility of applying to micro and small hydropower resources. The differential pressure exiting within the city water pipelines can be used efficiently to generate electricity like the energy generated through gravitational potential energy in dams. In order to reduce water pressure at the inlet of water cleaning centers, pressure reducing valves are used widely. Therefore, pressure energy is wasted. Instead of using the pressure reduction valve, a micro counter-rotating hydraulic turbine can be replaced to get energy caused by the large differential pressure found in the city water pipelines. In this study, in order to acquire design data of counter-rotating tubular type micro-turbine, output power, head, and efficiency characteristics due to the diffuser.

  • PDF

A Study on the Microcomputer-based PID Governor for Small Hydro Power Plant (마이크로 컴퓨터를 이용한 소수력발전소 PID 조속기에 관한 연구)

  • 신동렬;이규현;이원용
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.7
    • /
    • pp.492-500
    • /
    • 1987
  • Microcomputer-based PID governor which can be provided either stability or rapid response for small hydro power plant at low cost is developed and adapted to the 5 KW model hydro power for the performance test. The effects of PID gains on stability boundaries of the hydraulic turbine generating system is investigated. For the optimum selection of the PID gains, general equations are derived on the base of the experiments. This control system has a good performance at the model of hydro power plant. For the prediction of the control system, a mathematical model was developed and the results of the simulation using this model was matched with the experimental results.

  • PDF

Micro-Hydropower System with a Semi-Kaplan Turbine for Sewage Treatment Plant Application: Kiheung Respia Case Study (하수처리장 적용을 위한 Semi-카플란 수차가 장착된 마이크로수력발전 시스템: 기흥레스피아 사례)

  • Chae, Kyu-Jung;Kim, Dong-Soo;Cheon, Kyung-Ho;Kim, Won-Kyoung;Kim, Jung-Yeon;Lee, Chul-Hyung;Park, Wan-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.363-370
    • /
    • 2013
  • Small scale hydropower is one of most attractive and cost-effective energy technologies for installation within sewage treatment plants. This study was conducted to evaluate the potential of a semi-kaplan micro-hydropower (MHP) system for application to sewage treatment plants with high flow fluctuations and a low head. The semi-kaplan MHP is equipped with an adjustable runner blade, and is without a guide vane, so as to reduce the incidence of mechanical problems. A MHP rating 13.4 kWp with a semi-kaplan turbine has been considered for Kiheung Respia sewage treatment plant, and this installation is estimated to generate 86.8 MWh of electricity annually, which is enough to supply electricity to over 25 households, and equivalent to an annual reduction of 49 ton $CO_2$. The semi-kaplan turbine showed a 90.2% energy conversion efficiency at the design flow rate of 0.35 $m^3/s$ and net head of 4.7 m, and was adaptable to a wide range of flow fluctuations. Through the MHP operation, approximately 2.1% of total electricity demand of Kiheung Respia sewage treatment plant will be achievable. Based on financial analysis, an exploiting MHP is considered economically acceptable with an internal rate of return of 6.1%, net present value of 15,539,000 Korean Won, benefit-cost ratio of 1.08, and payback year of 15.5, respectively, if initial investment cost is 200,000,000 Korean Won.