• Title/Summary/Keyword: 마이크로파 라디오미터

Search Result 10, Processing Time 0.025 seconds

A Study on a Human Body Detection Sensor Using Microwave Radiometer Technologies (마이크로파 라디오미터 기술을 응용한 인체 감지 센서에 관한 연구)

  • Son, Hong-Min;Park, Hong-Kyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.333-340
    • /
    • 2015
  • In this paper, we propose a passive microwave sensor for detecting human body using microwave radiometer technologies. The proposed sensor detects human body by measuring the change of the received radiation power from fixed background object due to human body. A C-band microwave radiometer is designed and implemented. The received radiation power changes due to human body is measured by the C-band microwave radiometer, and the effectiveness of the proposed sensor is evaluated by the measurement result analysis.

Design of a Microwave Radiometer Receiver for Soil Moisture monitoring (토양 수분 모니터링용 마이크로파 라디오미터 수신기 설계)

  • Son, Hong-Min;Park, Hong-Kyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.173-180
    • /
    • 2014
  • The development process of a L-Band microwave radiometer for remote sensing of soil-moisture are described in this paper. Achieving the development aim of the measurement accuracy within 2% for soil moisture content of 0~50%, the requirements and specifications of the microwave radiometer and its receiver are drawn. The receiver with high gain, high sensitivity is designed and implemented to satisfy these requirements and specifications. The receiver has the bandwidth of 40 MHz, the system gain of 50 dB and the sensitivity of average value 0.19 K, maximum value 0.313K at 1390 MHz.

System Requirement Analysis of Passive Microwave Radiometer in Earth Observation Satellite (지구관측위성 수동형 마이크로파 라디오미터의 시스템 설계 요구 사항 분석 연구)

  • Ryu, Sang-Burm;Yong, Sang-Soon;Lee, Sang-Kon;Lee, Seung-Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.2
    • /
    • pp.87-96
    • /
    • 2012
  • In this research, we describe recent technologies and system requirements of the passive microwave radiometer used in Earth observation satellites. And we classify types of microwave radiometer system for Earth observation satellites according to observation targets and ways to scan and discuss a design method. Also, requirements of passive radiometer for Earth observation missions in the latest practical examples used and developed are analyzed in this research.

Development of a Microwave Radiometer for Remote Sensing of Water Surface Temperature (수면 온도 원격탐사용 마이크로파 라디오미터의 개발)

  • Son, Hong-Min;Youn, Jeong-Beam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1107-1115
    • /
    • 2012
  • This paper presents the development processes of a microwave radiometer for remote sensing of water surface temperature. Achieving the measurement accuracy within $2^{\circ}C$ for water surface temperature of $5{\sim}30^{\circ}C$, the requirements and specifications of the microwave radiometer and its receiver are drawn. The receiver with high gain, high sensitivity is designed and implemented. The receiver has the bandwidth of 50 MHz, the system gain of 45.2 dB and the sensitivity of 0.56K at 5.02 GHz. The effectiveness of the developed microwave radiometer in the measurement of water surface temperature is demonstrated experimentally. The results show the microwave radiometer can detect water surface temperature for $7.5{\sim}18^{\circ}C$ within the accuracy of $0.45^{\circ}C$.

Development of a L-Band Microwave Radiometer for Remote Sensing of Water Surface Salinity (수면 염분 원격탐사용 L-Band 마이크로파 라디오미터의 개발)

  • Son, Hong-Min;Youn, Jeong-Beam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.9
    • /
    • pp.900-907
    • /
    • 2013
  • The development processes of a L-band microwave radiometer for remote sensing of water surface salinity are described in this paper. Achieving the development aim of the measurement accuracy within 2 psu for water surface salinity of 0~40 psu, the requirements and specifications of the microwave radiometer and its receiver are drawn. The receiver with high gain, high sensitivity is designed and implemented to satisfy these requirements and specifications. The receiver has the bandwidth of 45 MHz, the system gain of 47 dB and the sensitivity of 0.41 K at 1,390 MHz. The effectiveness of the developed L-band microwave radiometer for remote sensing of water surface salinity is demonstrated experimentally. The results show the microwave radiometer can detect water surface salinity for 10~28 psu within the accuracy of 1.4 psu.

Development of a Microwave Radiometer for Remote Sensing of Oil Spills on the Water Surface (수면 기름 유출 원격 탐사용 마이크로파 라디오미터의 개발)

  • Son, Hong-Min;Park, Jin-Woo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.858-867
    • /
    • 2011
  • In this paper, we propose a microwave radiometer for remote sensing of oil spills on the water surface. In order to achieve the development aim of the measurement accuracy within 0.2 mm for oil slicks of 0~4 mm thickness, the requirements of the microwave radiometer and the specifications of its receiver are drawn. From these requirements and specifications, the receiver with high gain, high sensitivity is designed and implemented. The receiver has the bandwidth of 58 MHz, the system gain of 47.3 dB and the sensitivity of 0.46 K at 10.65 GHz. The processes of design and implementation of the receiver are described in this paper. The effectiveness of the proposed microwave radiometer in the measurement of oil slicks is demonstrated experimentally. The results show the microwave radiometer can detect the oil slicks for 0~5 mm thickness within the accuracy of 0.13 mm successfully.

Harmonic-Suppressed Hairpin Bandpass Filter for the Microwave Radiometer (마이크로파 라디오미터를 위한 하모닉 억제 특성을 가진 헤어핀 필터)

  • Yun, Tae-Soon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.10
    • /
    • pp.1169-1174
    • /
    • 2014
  • In this paper, for improving the performance of selecting and the sensitivity of the L-Band microwave radiometer for remote sensing of soil-moisture, the harmonic-suppressed hairpin bandpass filter is described. As the harmonic frequencies of the SIR can be controlled by the ratio of the impedance and electrical length, SIRs are used in the hairpin BPF for suppressing harmonics. Manufactured harmonic-suppressed hairpin BPF has the SIRs of three types and its harmonic is suppressed under 35 [dB] until 5 times of the center frequency of 1390 [MHz].

Modified Microwave Radio-thermometer for Measuring Temperature of Living Body (생체의 온도 측정을 위한 수정된 마이크로파 라디오-써모미터)

  • Kim Tae-Woo;Cho Tae-Kyung;Park Byoung-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.2 s.302
    • /
    • pp.27-32
    • /
    • 2005
  • This paper presents a modified microwave radio-thermometer (MRTM) with material characteristic estimator and multiple temperature conversion tables to measure subcutaneous temperature of a living body This estimator provides a temperature retrieval unit with the data of material characteristics such as permittivity, conductivity, thickness and geometry of the living body. The temperature retrieval unit with multiple temperature conversion tables can select one of the tables and computes temperature value corresponding to measured radiation power. In the experiments, it was shown that the MRTM could reduce measurement errors of about $0.82^{\circ}C\;to\;7.68^{\circ}C$ for the cases of distilled water and mixed liquid at the temperature of $37^{\circ}C$.

Current Status and Future Prospects of Satellite Payloads Technology (인공위성 탑재체 기술 현황 및 전망)

  • Yong, Sang-Soon;Kang, Gm-Sil;Heo, Haeng-Pal
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.8
    • /
    • pp.710-717
    • /
    • 2016
  • Satellite payload can be classified as electro-optical payload, SAR, microwave radiometer, communication payload, navigation payload and so on in accordance with the mission objective. The technology of satellite payload was tried to be obtained through development of KOMPSAT series, COMS and STSAT in Korea. In this paper, the required technology for the development and world market trend of satellite payload were studied and described. Since KOMPSAT program has been started in 1994, technology status and future prospects of satellite payload in Korea are studied and analyzed.

Implementing Graphic User Interface System for Microwave Radiometry Data to Utilize Breast Cancer Diagnosis (유방암 진단 활용을 위한 마이크로파 라디오미터 측정 데이터의 GUI 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Lee, Jeong-Whan;Han, Jong-Sam;Heo, Kyou-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.818-824
    • /
    • 2013
  • In this study, a novel Graphic User Interface (GUI) software development system is suggested so that it can be applied to diagnose breast cancer with utilizing 3~4.2 GHz microwave radiometric data. The estimated inner and surface temperature values on the patient's right and left breast in terms of microwave radiometry are visualized in HSV color mapping space and their relevant contour regions and lines are depicted by Marching Square graphic algorithm. Also the database system is implemented in terms of patient and diagnostic module to support the medical decisions concerning the breast cancer diagnosis.