• Title/Summary/Keyword: 마이크로챔버

Search Result 62, Processing Time 0.027 seconds

Three Dimensional Electro-Fluid-Structural Interaction Simulation for Pumping Performance Evaluation of a Valveless Micropump (무밸브 마이크로 펌프의 성능평가를 위한 3차원 전기-유체-구조 상호작용 해석)

  • Pham, My;Phan, Van Phuoc;Han, Cheol-Heui;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.744-750
    • /
    • 2009
  • In this study, the pumping performance of a piezoelectric valveless micropump is simulated. The micropump, which was developed in the previous work, is composed of a four-layer lightweight piezocomposite actuator, a polydimethylsiloxane (PDMS) pump chamber, and two diffusers. The piezoelectric domain, the fluid domain and the structural domain are coupled in the three-dimensional simulation. We used ANSYS for the piezoelectric and structural domains and ANSYS CFX for the fluid domain. The effects of driven frequency on the flow rate have been investigated by simulating the flow characteristics for 10 Hz and 40 Hz driven frequencies. The flow rates with respect to driven frequencies up to 300 Hz have been calculated.

Performance Evaluation of Rotational Flow of a 2×2 Microfluidic Centrifuge with varying Inlet Conditions and Chamber Sizes (마이크로 유체 원심분리기의 입구 조건과 챔버 크기에 따른 회전 유동 성능 평가)

  • Jeon, Hyeong Jin;Kwon, Bong Hyun;Kim, Dae Il;Kim, Hyung Hoon;Go, Jeung Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • This paper describes the measurement of performance evaluation of rotational flow varying chamber size and Reynolds number. Through the experimental visualization of the flow rotation, the number and position of flow rotation in the $2{\times}2$ microfluidic centrifuge were examined. At a chamber width of 250${\mu}m$, single flow rotation was obtained over at a Reynolds number of 300, while at a chamber width of 500 ${\mu}m$, single flow rotation did not appear. For performance evaluation, the intensity in microchamber was measured during 20 sec. At a chamber width of 250 ${\mu}m$, performance of rotational flow increased as Reynolds number increased. However, the variation of intensity in microchamber remained unchanged at a chamber width of 500 ${\mu}m$. The numerical analysis showed that the threshold centrifugal acceleration to obtain rotational flow for ejected particles was 200g.

Development of having double-chamber in micro-bubble pump (두 개의 챔버를 갖는 마이크로 버블펌프의 개발)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

Visualization of Rotational Flow for Chamber Size of a 2×2 Microfluidic Centrifuge (마이크로 유체 원심분리기의 챔버 크기에 따른 회전 유동 가시화)

  • Jeon, Hyeong Jin;Kwon, Bong Hyun;Kim, Dae Il;Go, Jeung Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.25-29
    • /
    • 2012
  • This paper introduces a new parameter to design the $2{\times}2$ microfluidic centrifuge with single flow rotation positioned at the center of microchamber. The dimensional centrifugal acceleration momentum flux which is defined as the interfacial momentum flux divided by distance from the center of the chamber explains the flow rotation and its threshold provides a reference to expect single flow rotation. Through the numerical and experimental visualization of the flow rotation, the number and position of flow rotation in the $2{\times}2$ microfluidic centrifuge were examined. At a channel width of $50{\mu}m$ and chamber width of $250{\mu}m$, single flow rotation was obtained over at a Reynolds number of 300, while at a channel width of $100{\mu}m$ and chamber width of $500{\mu}m$, single flow rotation did not appear. The numerical analysis showed that the threshold centrifugal acceleration momentum flux to obtain single flow rotation was $3500kg/m{\cdot}s^2$.

Cathode Power Development of Hall Thruster for Small Satellite using Microwave cathode (마이크로웨이브 음극을 이용한 소형 인공위성의 홀 추력기용 음극전원 개발)

  • Kang, Seokhyun;Choo, Wongyo;Choi, Junku;Jeong, Yunhwang;Kim, Younho;Kang, Seongmin;Kuninaka, Hitoshi;Cha, Hanju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.974-980
    • /
    • 2014
  • A power supply of cathode has been developed for hall-effect thruster for small satellite. A microwave cathode has been applied to the electric propulsion system and cathode power is necessary in oder to work securely. Anode current is varied by a flow rate controlled by anode tank pressure. Then cathode current has to be controled in proportion by anode current. So cathode power supply has been designed to offer a current proportional to anode current. Also cathode power has been tuned to work securely for cathode to emit more electron than anode within 0.03A. The function test of cathode power was performed by constructing an equivalent load for anode and cathode. It has been tested in a vacuum chamber in order to ensure a stable operation of the thruster. And it was confirmed that thruster normally has been operated in the space environment after the launch.

Design and Analysis of Piezoelectric Micro-Pump Using Traveling-Wave (진행파를 이용한 압전 마이크로 펌프의 설계와 해석)

  • Na, Yeong Min;Lee, Hyun Seok;Park, Jong Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.567-573
    • /
    • 2014
  • Since the development of microelectromechanical systems (MEMS) technology for the medical field, various micro-fluid transfer systems have been studied. This paper proposes a micro-piezoelectric pump that imitates a stomach's peristalsis by using two separate piezoelectric elements, in contrast to existing micro-pumps. This piezoelectric pump is operated by using the valve-less traveling wave of peristalsis movement. If the piezoelectric plates at the two separated plates are actuated at the input voltage, a traveling wave occurs between the two plates. Then, the fluid migrates by the pressure difference generated by the traveling wave. Finite element analysis was performed to understand the mechanics of the combined system with piezoelectric elements, elastic structures, and fluids. The effects of design variables such as the chamber height and number of ceramics on the flow rate of the fluid were examined.

Cross-sectional Radiation Type Mixer into the Boundary Surface using PMN-PT for Micromixing (마이크로믹서에의 응용을 위해 PMN-PT를 이용한 경계면과 수직방향 방사형 믹서)

  • Heo Pil Woo;Yoon Eui Soo;Kho Kwang Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.1
    • /
    • pp.33-37
    • /
    • 2005
  • A micromixer plays an important role in Bio-MEMS or μ-TAS. Mixing is generally generated by turbulence and interdiffusion of two fluids. Because of low Reynolds number values (Re << 2000) within microchannels, it is difficult to generate turbulence, and consequently mixing mainly depends on interdiffusion. So, channel distance is often prohibitively long to mix two different fluids properly. To reduce this mixing length, we proposed a new mixer for micromixing in which two fluids were effectively mixed by an ultrasonic wave generated by PMN-PT. The ultrasonic wave was radiated into a chamber In the cross-sectional direction into the boundary surface formed by two fluids. The two fluids were positioned one on top of the other. The mixing state was measured by observing the color of samples due to the reaction of NaOH and phenolphthalein.

Fabrication of a Micro-thermoelectric Probe (마이크로 프로브 기반 열전 센서 제작 기술)

  • Chang, Won-Seok;Choi, Tae-Youl
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1133-1137
    • /
    • 2011
  • A novel technique for the fabrication of a glass micropipette-based thermal sensor was developed utilizing inexpensive thermocouple materials. Thermal fluctuation with a resolution of ${\pm}0.002$ K was measured using the fabricated thermal probe. The sensors comprise unleaded low-melting point solder alloy (Sn) as a core metal inside a borosilicate glass pipette coated with a thin film of Ni, creating a thermocouple junction at the tip. The sensor was calibrated using a thermally insulated calibration chamber, the temperature of which can be controlled with a precision of ${\pm}0.1$ K and the thermoelectric power (Seebeck coefficient) of the sensor was recorded from 8.46 to $8.86{\mu}V$/K. The sensor we have produced is both cost-effective and reliable for thermal conductivity measurements of micro-electromechanical systems (MEMS) and biological temperature sensing at the micron level.

Fabrication, Performance Evaluation of Components of Planar Type MEMS Solid Propellant Thruster (평판형 MEMS 고체 추진제 추력기 요소 제작 및 성능 평가)

  • Park, Jong-Ik;Kwon, Se-Jjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.6
    • /
    • pp.581-586
    • /
    • 2008
  • The MEMS solid propellant thrusters have very low thrust level for applying to the propulsion system of micro/nano satellites or the side jet thruster of smart bombs. In this research, the fabrication possibility of planar type MEMS solid propellant thrusters that have enlarged burning surface area was examined and the safety of the structure of thruster during the firing test was confirmed. The performance of a micro igniter which is the key component of the MEMS solid propellant thruster was estimated by the ANSYS Icepak and evaluated by the experiment. Finally, the thrust was measured by the micro force sensor. The levels of thrust were 300, 600 mN in the case of K=15, 20.

Humidity Sensor Using Microwave Sensor Based on Microstrip Defected Ground Structure Coated with Polyvinyl Alcohol (폴리비닐알코올로 코팅된 마이크로스트립 결함 접지 구조 기반 마이크로파 센서를 이용한 습도 센서)

  • Yeo, Junho;Kwon, Younghwan
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.627-632
    • /
    • 2020
  • In this paper, we have studied a development of a humidity sensor using a microwave sensor based on a microstrip defected ground structure coated with polyvinyl alcohol. A high-sensitivity microwave sensor, which is sensitive to the changes in the permittivity of the material under test, is designed by adding an interdigital capacitor-shaped defected ground structure to the ground plane of a microstrip line. Polyvinyl alcohol, a polymer material whose permittivity varies depending on humidity, is coated with a thin thickness on the defected ground structure of the proposed microwave sensor, and the changes in the resonance frequency and magnitude of the transmission coefficient for the microwave sensor according to humidity are measured. When relative humidity increases from 40% to 80% in 10% increments at a temperature of 25 degrees using a temperature/humidity chamber, the resonant frequency of the transmission coefficient decreases from 1.475 GHz to 1.449 GHz, and the magnitude is increased from -32.90 dB to -25.67 dB.