• Title/Summary/Keyword: 마모 저항성

Search Result 127, Processing Time 0.034 seconds

Experimental Study on Vibration Reduction Characteristics of Polymer Concrete (폴리머 콘크리트의 진동저감 특성에 대한 실험적 연구)

  • Kim, Jeong-Jin;Shim, Hak-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.58-65
    • /
    • 2019
  • Polymer concrete is expected to be widely used as a building material because it has a shorter hardening time and excellent compression, tensile, bending, bond strength, frictional resistance and abrasion loss compared to general concrete. The polymer concrete has excellent vibration damping performance and research on the use of various reinforcing materials is being conducted. However, in order to completely replace the general concrete and the general anti-vibration reinforcement, such polymer concrete requires an overall review of vibration reduction performance considering physical properties, dynamic properties, productivity and field applicability. In this study, the physical and dynamic properties of polymer concrete by epoxy mixing ratio were compared with those of general concrete. It was appeared that compression, tensile, bending and bond strengths of polymer concrete by epoxy mixing were significantly higher than those of general concrete. Especially, the tensile strength was more than 4 ~ 6.5 times. Based on the basic physical properties of polymer concrete, the damping ratio, which is a dynamic characteristic according to the epoxy mixing ratio, was derived through analytical models and experiments. As a result, the dynamic stiffness of polymer concrete was 20% higher than that of general concrete and the loss rate was about 3 times higher.

Development of rotor overlay welding process (로타 오버레이 용접공정 개발)

  • Lee, Kyong-Woon;Kim, Dong-Jin;Kang, Sung-Tae
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.12-12
    • /
    • 2009
  • 터빈에서 핵심부품인 로터는 블레이드를 원심 운동시키는 대형 단조강이며, 고압의 증기 조건에서 고속회전하며 고온에서 운전과 저온에서 과속시험 동안 높은 원심력을 받는다. 또한 기동/정지 천이 동안 열응력을 받기 때문에, 이러한 운전조건에 부합되는 소재로서는 높은 Creep 강도 및 피로강도를 가지는 CrMoV type의 강종이 사용되어져 왔다. 발전소의 대용량화 및 고온화에 따라 종래의 증기조건에서 사용되어져 왔던 1%CrMoV강은 내산화성 및 내부식성이 문제가 되어 더 이상 사용이 불가하며, 고온/고압하에서도 우수한 소재 특성을 가지는 12%Cr강의 사용이 필수적이다. 그러나 12%Cr강으로 제작되는 로타는 Cr 양이 높기 때문에 저널부에 Galling 또는 Scuffing 이라 불리는 부적절한 마모현상과 사용 중 소착이 발생하기 쉬운 단점이 있기 때문에, 저널부에 Cr 함유량 2~3% 이하의 저합금강을 오버레이 용접하여 육성하는 일체형 가공구조의 로타 저널부가 주목되어 왔다. 따라서 본 연구에서는 Large scale 로타가 용접 도중 급열 및 급냉이 되지 않으면서 균일한 온도로 일정 시간 유지할 수 있는 열관리 장치 개발, 최적 오버레이 용접조건 선정 및 용접부 건전성 시험 평가를 통하여 12%Cr 로타 저널부의 최적 오버레이 용접공정을 확립하고자 하였다. 용접 열관리 장치는 전기저항 가열방식을 적용하고 있으며 용접이 최종 완료되기 전까지 로타 제품 전체는 $93^{\circ}C$이상의 온도로 유지 되어져야 하며, 규정 용접후열처리 온도는 $650^{\circ}C{\pm}14^{\circ}C$ 이다. 또한 로타 오버레이 용접은 모재 Set up $\Rightarrow$ 용접예열 $\Rightarrow$ GTA용접 $\Rightarrow$ SA용접 $\Rightarrow$ 용접후열(Post heating) $\Rightarrow$ 용접후열처리(PWHT) $\Rightarrow$ 정삭가공 $\Rightarrow$ NDE(UT) 순으로 수행 되어진다 실제 로타의 1/3 Scale로 시험편을 제작하여, 오버레이 mockup 시험을 수행한 후 화학성분, 경도 분포, 인장강도, 충격인성 및 굽힘시험을 수행한 결과, 오버레이 용접에서 요구되어지는 용접 물성값을 만족하는 것으로 확인되었다. 또한 균열 등의 선형 결함이나 기공, 슬라그 혼입과 같은 결함은 관찰되지 않았으며, 용접 시 아크의 안정성과 슬라그의 박리성은 양호하였으며 비드의 외관도 미려하여 용접 작업성도 양호하였다.

  • PDF

Improvement of Abrasion and Debris on Styrene-Butadiene-Styrene Block Copolymer with Carboxylated SBR Latex and Zinc Oxide (카르복실화 SBR 라텍스와 산화아연을 이용한 SBS의 내마모성과 데브리스(debris) 개선 연구)

  • Lee, Jin Hyok;Bae, Jong Woo;Kim, Jung Su;Yoon, Yoo-Mi;Jo, Nam-Ju
    • Elastomers and Composites
    • /
    • v.48 no.3
    • /
    • pp.225-231
    • /
    • 2013
  • In this study, we observed the effect of carboxylated SBR latex and zinc oxide on styrene-butadiene-styrene( SBS) composites for improving abrasion and debris. SBS composite, which added only silica, showed poor mechanical properties, NBS abrasion, and debris, caused by strong filler-filler interaction of silica. In case of adding carboxylated SBR latex, mechanical properties, NBS abrasion and debris of SBS composite were improved. Because of carboxyl group of carboxylated SBR latex interacted with silanol group of silica. Both carboxylated SBR latex and zinc oxide were added, SBS composite showed highest mechanical properties, NBS abrasion, and debris by forming ion cluster between carboxylated SBR latex and zinc oxide. By FT-IR analysis, ion clusters were confirmed that observed zinc carboxylated group stretch peak at $1550{\sim}1650cm^{-1}$ range. SBS composite, SC-4, showed excellent mechanical properties ; tensile strength $156kgf/cm^2$, elongation 936%, tear strength 59.4kgf/cm ; and excellent abrasion characteristics ; NBS abrasion 338%. Also, debris of SC-4 was minimized and showed wave-shape in fracture surface.

CHEMICAL DEGRADATION OF LIGHT-CURED DENTAL COMPOSITE RESINS (수종 치과용 광중합형 복합레진의 화학적 분해)

  • Yang, Kuy-Ho;Choi, Nam-Ki;Park, Mi-Ran;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.403-411
    • /
    • 2001
  • The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. The brands studied were Unifil(GC, Japan), Palfique(Tokuyama Japan). Definite$Degussa-H\ddot{u}ls$ AG, Germany). Revolution(Kerr, U.S.A.). Preweighed discs of each brand were exposed 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters: (a) mass loss(%) - determined from pre-and post-exposed specimen weights; (b) Si loss(ppm) - obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation depth$({\mu}m)$ - measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. The mass loss of Unifil was 3.21%, it was the highest of materials. But, there was no significant difference among the materials. 2. The degree of degradation layer depth was $107.69\sim47.40{\mu}m$, the sequence of the degree pf degradation layer depth was in descending order by Unifil, Palfique, Revolution, Definite. There was significant difference among the materials except Palfique and Definite. 3. The Si loss of Paltique was 8940.0ppm, it was the highest. There was significant difference among the materials, except Revolution and Definite(p<0.05). 4. The correlation coefficient between mass loss and degradation depth was relatively high(r = 0.06, p<0.05). 5. There was no significant coefficient correlation between Si loss and mass loss, and/or the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler. Above results suggested that the hydrolytic degradation is considered as evaluation factor of composite resins.

  • PDF

Experimental Study on the Shearing and Crushing Characteristics of Subaqueous Gravels in Gravel Bed River (수중 자갈의 전단 및 파쇄 특성에 관한 실험적 연구)

  • Kim, So-Ra;Jeong, Sueng-Won;Lee, Gwang-Soo;Yoo, Dong-Geun
    • Journal of the Korean earth science society
    • /
    • v.42 no.2
    • /
    • pp.164-174
    • /
    • 2021
  • The study examines the shearing and crushing characteristics of land-derived subaqueous granular materials in a gravel-bed river. A series of large-sized ring shear tests were performed to examine the effect of shear time and shear velocity on the shear stress characteristics of aquarium gravels with a 6-mm mean grain size. Three different shear velocities (i.e., 0.01, 0.1, and 1 mm/sec) were applied to measure the shear stress under the drained (long-term shearing) and undrained (short-term shearing) conditions. Different initial shear velocities, i.e., 0.01→0.1→1 mm/sec and 0.1→0.01→1 mm/sec, were considered in this study. The test results show that the grain crushing effect is significant regardless of drainage conditions. The shear stress of coarse-grained materials is influenced by initial shear velocities, regardless of the drainage conditions. In particular, particle breakage increases as grain size increases. The shearing time and initial shear velocity are the primary influencing factors determining the shear stress of gravels. The granular materials may be broken easily into particles through frictional resistance, such as abrasion, interlocking and fracture due to the particle-particle interaction, resulting in the high mobility of granular materials in a subaqueous environment.

The effect of various foods on the color stability of artificial teeth (여러가지 음식물에 따른 인공치의 색 안정성에 관한 연구)

  • Lee, Youngil-Il;Cho, In-Ho;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.82-90
    • /
    • 2009
  • Statement of problem: Recently, as patients' expectation and interest for esthetics are increasing, concerns of esthetic restoration for removable dentures as well as fixed prosthodontics are also increasing. And the color stability of artificial teeth will affect a long term success rate of the denture. But the stain or discoloration of these artificial teeth as well as denture resin has caused esthetic problem. Purpose: This study was designed to evaluate the influence on color stability of artificial teeth when soy sauce, red pepper paste and coffee which many Koreans have eaten were applied. Material and methods: For artificial teeth type(Endura $Anterio^{(R)}$, Physio $Duracross^{(R)}$, Trubyte $Biotone^{(R)}$) selected for the study, 10 specimens each were soaked into individual beakers of soy sauce, red pepper paste, coffee and distilled water. And $L^*$, $a^*$, $b^*$ value were measured for evaluation of the color difference (${\Delta}E^*$) with spectrophotometer on the 1 day, 1 week, 2 weeks, 4 weeks and 8 weeks after immersion. Results: 1. ${\Delta}E^*$ value of artificial teeth which were soaked in soy sauce and coffee was various according to soaking periods. However there was significant difference between Trubyte $Biotone^{(R)}$ and Physio $Duracross^{(R)}$ in red pepper paste regardless of soaking period(P<.05). 2. Except for 8 weeks of Endura $Anterio^{(R)}$, 4 weeks and 8 weeks of Physio $Duracross^{(R)}$, artificial teeth soaked in red pepper paste regardless of the type had significant difference of ${\Delta}E^*$ value compared with other groups (P<.05). 3. $a^*$, $b^*$ value of Endura $Anterio^{(R)}$ and Trubyte $Biotone^{(R)}$ which were soaked in red pepper paste had significant difference compared with the value of other group(P<.05). Conclusion: Red pepper paste had the greatest effect on color difference of artificial tooth. Physio $Duracross^{(R)}$ showed relatively less color difference than Trubyte $Biotone^{(R)}$ and Endura $Anterio^{(R)}$. But as ${\Delta}E^*$ difference were all less than 3.3, these artificial resin teeth seemed appropriate for clinical use.

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.