• Title/Summary/Keyword: 링-테스트

Search Result 546, Processing Time 0.027 seconds

Mechanical Properties of Ta/TaN Multilayer (Ta/TaN 복합 다층 피막의 기계적 특성)

  • Gang, Yeong-Gwon;Lee, Jong-Mu;Choe, Sang-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.8
    • /
    • pp.837-842
    • /
    • 1999
  • The Ta/TaN multilayer structure with repeating layers of a poly-crystalline Ta layer of high ductility and a TaN layer of high hardness is expected to exhibit toughness. This paper reports the results on the hardness and the adhesion strength of Ta/TaN multilayers and compositional gradient Ta/TaN layers deposited on the high speed steel substrate by reactive sputtering as a function of annealing temperature. The TaN film deposited with the $N_2$/Ar ratio of 0.4 in the reactive sputtering process exhibits the highest crystallinity, and the highest hardness and the results of scratch test of the Ta/TaN multilayers. The hardness and adhesion strength of the Ta/TaN multilayers becomes deteriorated with increasing the annealing temperature in the heat treatment right after depositing the layers. Therefore, post-annealing treatments are not desirable in the case of the Ta/TaN multilayers from the standpoint of mechanical properties. Also the hardness of Ta/TaN multilayers increases with decreasing the compositional modulation wavelength, but the adhesion property of the layers is nearly independent of the wavelength. On the other hand, the compositional gradient Ta/TaN film exhibits the highest hardness and the value of scratch test for the post-annealing temperatures of 20$0^{\circ}C$ and 40$0^{\circ}C$, respectively. This tendency of the compositional gradient Ta/TaN films differs from that of the Ta/TaN multilayers.

  • PDF

Evaluation of Field Application and Optimum Operational Condition for Heavy Metals Analysis Using Environment-Friendly Bismuth Film Electrode (친환경 비스무스 필름 전극을 이용한 중금속 분석 최적조건 도출 및 현장 적용성 평가)

  • Kim, So-Youn;Yang, Yong-Woon;Jeon, Sook-Lye
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.2
    • /
    • pp.137-142
    • /
    • 2011
  • This study was conducted to establish the optimal electrolyte and bismuth concentrations using bismuth film electrode in laboratory and to confirm the possibilities of using this operational condition for heavy metals monitoring in field. In lab test, heavy metal measurement was not accurate more than 600 ppb when heavy metal (Pb, Cd, Zn) range 100~1,000 ppb was measured with bismuth 2,000 ppb. So, bismuth and heavy metal was reacted about 1:1 with ASV method. In electrolyte test, 0.1 M acetate buffer (pH 4.5), 0.1 M chloroacetate buffer (pH 2.0), 0.1 M HCl (pH 2.0), 0.1 M $HNO_3$ (pH 2.0) was tested. As a results, 0.1 M acetate buffer was most suitable in ASV measurement with bismuth film electrode. In field application, Pb, Cd and Zn was measured respectively 36~45 ppb, 84~91 ppb, 90~98 ppb when heavy metal (Pb, Cd, Zn) 100 ppb was spiked in field sample. These results were identified of matrix effect in field sample, So relationship between heavy metal measurement and matrix effects will be studied.

Real-Time Construction Resource Monitoring using RFID/USN Inter-working System (RFID/USN 연동 시스템을 활용한 건설자원 실시간 모니터링 시스템)

  • Ryu, Jeoung-Pil;Kim, Hyoung-Kwan;Kim, Chang-Yoon;Kim, Chang-Wan;Han, Seung-Heon;Kim, Moon-Kyum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.90-94
    • /
    • 2007
  • Location tracking automation of resources in construction industry is one of the most important procedures to improve construction project performance and reduce the period of construction. Recently, location tracking technologies have proven to be effective in tracking construction materials and equipment in real time through the instrumentality of RFID (Radio Frequency Identification). By using wireless communication and inter-working system between RFID and USN, it is possible that construction engineers receive the location information of construction resources without additional efforts that move the RFID reader to read tags periodically. In the inter-working system, RFID reader delivers the acquired materials information to sensor node which is connected by serial interface. Then sensor node transmits the received data to the data aggregation terminal that is a sink node. The data aggregation terminal can transmit collected data to construction manager who is out of construction site using infrastructure such as CDMA(Code Division Multiple Access) network. The combination model of the two system and field test scenarios are presented in this paper.

  • PDF

Application Testing and Comparative Effectiveness of Green-tide Mitigation Technique in the Lower Part (Chusori) of the So-ok Stream (Daecheong Reservoir), Korea (소옥천 하류(추소리)에서 녹조현상 경감기술의 현장 시험 적용 및 효과 비교)

  • Shin, Jae-Ki;Kim, Youngsung;Noh, Joonwoo;Kim, Jong-Myung;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.4
    • /
    • pp.258-270
    • /
    • 2016
  • This study was conducted to test the green-tide mitigation technique in the lower part of the Sook Stream (Chusori) of Daecheong Reservoir from June 27 to August 24, 2014. And the effects were compared with weekly monitoring result of the watching station of the algae alert system (AAS) as well as test beds reach. The green-tide in a test bed was begun from the upstream, and it was gradually transferred and spread toward the downstream by the hydrological factors. The total amount of algae removed by algae removal device during the test period was 33,920 kg, and solids dewatered by natural gravity was 8,480 kg. Also chlorophyll-a content was 2.83 kg, the number of blue-green algae cells was equivalent to $78.6{\times}10^{14}$ cells. Compared with the results of the watching station of AAS, the pre-concentrate removal work in the outbreak waters was able to suggest the possibility of green-tide mitigation. In addition, an effective management of the green-tide was required spatial and temporal occurrence information and practical device technology. Particularly, the optimal timing of algae removal in the river-reservoir hybrid system was recommended at times before the monsoon rainy season and reached the lowest water level.

A Study on the Sensory Tests Correlated Objective Measurements for the Gloss and Gloss-lasting Capability of Lipstick (립스틱의 광택 및 광택 지속성에 대한 객관적인 측정법에 관한 연구)

  • Kim, Kyung-Nam;Kim, Yoon-Jeong;Lee, Hwa-Young;Kim, Eun-Jeong;Cheon, Ji-Min;Kang, Hak-Hee;Lee, Ok-Sub
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.1 s.49
    • /
    • pp.59-64
    • /
    • 2005
  • In case of lipsticks, observer's subjective sensitivity has been the main index to estimate gloss and gloss-lasting capability. The glossmeter has been applied to measure the gloss of make-up cosmetics like nail enamel, however is not effective for lipstick because of uneven sampling. Also gloss-lasting capability couldn't have been measured. In this study, we optimized measurement methods of gloss and gloss-lasting capability of lipsticks, which are highly correlated to subjective sensory tests. We set up the standard methods of gloss measurement by changing application conditions, for example, materials, sizes and application number of times and so on. And we introduced optimizing measurement system, in which shaking speed and temperature were controlled to measure gloss-lasting capability. Applying our methods, the gloss values were very close to the results of sensory tests, and we could express the gloss and gloss-lasting capability of lipsticks numerically Repeatability and reproducibility of our methods were certified by six-sigma statistical tool.

Field Applications of Non-powered Downward Water Circulation System to Improve Reservoir Water Quality (저수지 수질개선을 위한 무동력 하향류 수류순환시스템의 현장적용성)

  • Jang, YeoJu;Lim, HyunMan;Jung, JinHong;Park, JaeRho;Kim, WeonJae
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.2
    • /
    • pp.109-119
    • /
    • 2019
  • Eutrophication has occurred due to the inflow of various water pollutants in many Korean reservoirs with low depth, and algal blooms of surface layer and low oxygenation of deep layer have repeated every year. There are several existing technologies to alleviate the stratification of reservoirs, but it is difficult to apply them in field sites due to the necessity of electric power and low economic efficiency. In this study, a non-powered water circulation system using natural energy of wind and water flow has been developed, and two test-beds constructed in the reservoirs with different conditions and examined its field applicability. Through computational fluid dynamics (CFD) simulation, it has been shown that the water circulation system could induce the downward flow to mitigate the stratification between surface and deep layers, and its influence radius could reach about 30 m. As a result of long-term monitoring of the test-beds, various water quality improvement effects have been observed such as moderation of DO fluctuation by water circulation, reduction of DO supersaturation and prevention of excessive pH rising. In order to improve the applicability of the water circulation system, it is considered necessary to review countermeasures against flood and depth conditions of each reservoir.

Connectivity Verification and Noise Reduction Analysis of Smart Safety Helmet for Shipyard Worker (조선소 작업자를 위한 스마트 안전모의 커넥티비티 검증 및 소음저감 분석)

  • Park, Junhyeok;Heo, Junyeoung;Lee, Sangbok;Park, Jaemun;Park, Jun-Soo;Lee, Kwangkook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.1
    • /
    • pp.28-36
    • /
    • 2022
  • Currently, the automation and intelligence of the shipbuilding industry have improved its work production capacity and cost competitiveness, but the reduction rate of safety accidents among industrial site workers is still low and the damage caused by safety accidents is very serious, so there is a need for improvement according to the workplace. This research aims to demonstrate the connectivity between smart safety helmets in the demonstration area to verify the effectiveness along with the development of smart helmets for worker protection and environmental safety in shipyards. For efficient communication between workers, impact noise of over 95dB was confirmed in the workplace, and noise reduction was required. To solve this problem, the filtering performance was compared and analyzed using the Butterworth, Chebyshev, and elliptic algorithms. The connectivity test and noise reduction method between smart helmets proposed in this study will increase the usability and safety of the field through the development of advanced smart helmets tailored to the shipbuilding workplace in the future.

Comparison of Laboratory Tests Applied for Diagnosing the SARS-CoV-2 Infection (SARS-CoV-2 감염의 진단에 이용되는 검사실 테스트의 비교)

  • Lee, Chang-Gun;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.2
    • /
    • pp.79-94
    • /
    • 2022
  • Due to the highly contagious nature and severity of the respiratory diseases caused by COVID-19, economical and accurate tests are required to better monitor and prevent the spread of this contagion. As the structural and molecular properties of SARS-CoV-2 were being revealed during the early stage of the COVID-19 pandemic, many manufacturers of COVID-19 diagnostic kits actively invested in the design, development, validation, verification, and implementation of diagnostic tests. Currently, diagnostic tests for SARS-CoV-2 are the most widely used and validated techniques for rapid antigen, and immuno-serological assays for specific IgG and IgM antibody tests and molecular diagnostic tests. Molecular diagnostic assays are the gold standard for direct detection of viral RNA in individuals suspected to be infected with SARS-CoV-2. Antibody-based serological tests are indirect tests applied to determine COVID-19 prevalence in the community and identify individuals who have obtained immunity. In the future, it is necessary to explore technical problems encountered in the early stages of global or regional outbreaks of pandemics and provide future directions for better diagnostic tests. This article evaluates the commercially available and FDA-approved molecular and immunological diagnostic assays and analyzes their performance characteristics.

Quantitative Estimation Method for ML Model Performance Change, Due to Concept Drift (Concept Drift에 의한 ML 모델 성능 변화의 정량적 추정 방법)

  • Soon-Hong An;Hoon-Suk Lee;Seung-Hoon Kim
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.12 no.6
    • /
    • pp.259-266
    • /
    • 2023
  • It is very difficult to measure the performance of the machine learning model in the business service stage. Therefore, managing the performance of the model through the operational department is not done effectively. Academically, various studies have been conducted on the concept drift detection method to determine whether the model status is appropriate. The operational department wants to know quantitatively the performance of the operating model, but concept drift can only detect the state of the model in relation to the data, it cannot estimate the quantitative performance of the model. In this study, we propose a performance prediction model (PPM) that quantitatively estimates precision through the statistics of concept drift. The proposed model induces artificial drift in the sampling data extracted from the training data, measures the precision of the sampling data, creates a dataset of drift and precision, and learns it. Then, the difference between the actual precision and the predicted precision is compared through the test data to correct the error of the performance prediction model. The proposed PPM was applied to two models, a loan underwriting model and a credit card fraud detection model that can be used in real business. It was confirmed that the precision was effectively predicted.

Monitoring and Development of Pretreatment Method for Perfluorinated Compounds in Fish Samples (어류에서의 과불화합물 분석을 위한 전처리법 확립 및 모니터링)

  • Heo, Jin-Ju;Lee, Ji-Woo;Kim, Seung-Kyu;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.485-494
    • /
    • 2013
  • An efficient extraction method was developed for the analysis of 16 perfluorinated compounds (PFCs) in fish samples. We compared the recoveries from the Ion-Pairing Extraction (IPE), Liquid-Liquid Extraction (LLE), Solid-Phase Extraction (SPE), IPE + SPE method with varying the injection time of the internal standard. As a result, IPE method with the internal standard before extraction was evaluated as the most effective pretreatment method. The RPM (Revolution Per Munite) and pH in IPE-before method were additionally adjusted and the more efficient pretreatment method was established. The total 33 fish samples including liver and gut samples were collected from Korean markets and analyzed PFCs with developed pretreatment method of this study. Total 16 PFC levels in fish samples ranged from ND to 1.67 ng/g with 100% detection frequency. The average PFCs concentrations of muscle, liver and gut samples from fish were compared and showed the following trend: liver (17.8 ng/g) > gut (13.3 ng/g) > muscle (1.67 ng/g). The PFC levels in fish samples were similar or lower than other available previous results of foreign studies.