• Title/Summary/Keyword: 리브 피치

Search Result 5, Processing Time 0.027 seconds

Heat Transfer of a Two-Dimensional Jet Impinging on the Wall with Transverse Repeated Ribs of Square Cross-Section (四角리브를 갖는 傳熱面에 衝突하는 2次元 噴流의 熱傳達에 관한 硏究)

  • 김상필;서정윤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.214-221
    • /
    • 1987
  • The purpose of this study is augmentation of heat transfer without additional power in the case of rectangular air jet which impinges vertically on the heating surface. The experimental results are obtained heat transfer augmentation of a two-dimensional impinging jet using the surface roughness of transverse repeated-rib type. The integral average heat transfer coefficient of ribbed plate is about two times larger than that of flat plate. In order to supplement the information about the mechanism of heat transfer augmentation, the flow structure in the stagnation region is visually studied by using the smoke wire technique. The heat transfer augmentation is due to the effect of stretching of large scale vortex in the stagnation region.

A Study on Heat Trasfer Characteristics of Smooth and Ribbed Tubes for Boiler (보일러용 裸管 및 리브붙이管 의 熱傳達 特性 에 관한 硏究)

  • 김종보;한승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.699-705
    • /
    • 1985
  • Heat transfer characteristics in terms of the tube wall-temperature and the enthalpy have been investigated utilizing ribbed (rifled) tubes in order to enhance heat transfer performance. Considerations were given for the cases of smooth tubes in order to compare with the case of ribbed tubes. The tilt angle of the experimental tubes are from 0.deg. to 90.deg. , in order to simulate the boiler water tubes having 15.deg.-90.deg. inclined angle in boiler nose and studded tubes (burner zones), Natural convection and forced convection (Re=1810) conditions were considered in the experiments. The experimental results for the effect for the tube inclination through a natural convection and forced convection are presented and it is shown that ribbed tubes permit an appreciable increase in heat transfer coefficients and consequently it means substantial reductions in boiler water wall tubes and heat exchanger surface areas.

Numerical Analysis of Thermal and Flow affected by the variation of rib interval and Pressure drop Characteristics (리브 간격 변화에 따른 열.유동 수치해석 및 압력 저하 특성)

  • Chung, Han-Shik;Lee, Gyeong-Wan;Shin, Yong-Han;Choi, Soon-Ho;Jeong, Hyo-Min
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.616-624
    • /
    • 2011
  • The flow characteristics and heat transfer augment on the periodically arranged semi-circular ribs in a rectangular channel for turbulent flow has been investigated numerically. The aspect ratio of the rectangular channel was AR=5, the rib height to hydraulic diameter ratio were 0.07 and rib height to channel height ratio was set as e/H=0.117 for various PR(rib pitch-to-rib height rate) between 8~14, respectively. The SST k-${\omega}$ turbulence model and v2-f turbulence model were used to find out the heat transfer and the flow characteristics of near the wall which are suited to obtain realistic phenomena. The numerical analysis results show turbulent flow characteristics, heat transfer enhancement and friction factor as observed experimentally. The results predict that turbulent kinetic energy(k) is closely relative to the diffusion of recirculation flow. and v2-f turbulence model simulation results have a good agreement with experimental values.

Effect of Rib Pitch on Heat Transfer and Friction Factor in a Two Wall Divergent Channel (2벽면 확대 사각채널에서 리브 피치가 열전달과 마찰계수에 미치는 효과)

  • Ahn, Soo Whan;Lee, Myung Sung;Jeong, Seong Soo;Bae, Sung Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.175-180
    • /
    • 2014
  • Experimental investigations of the heat transfer and friction factors in the ribbed divergent rectangular channel with the channel exit hydraulic diameter to inlet hydraulic diameter ratio of 1.16 were performed. The surface heaters were mounted onto the two opposite walls. The main experimental parameter is the ratio of rib pitch (p) to height (e), at which the ratios (p/e) of 6, 10, and 14 are considered in the channel with ribs on one wall only. The straight ribbed square channel is also considered as a comparison. The major findings are that the ratio of p/e = 6 shows the highest values in the heat transfer and the ratio of p/e = 10 indicates the greatest friction factor in the ribbed divergent channel. Editor's note:No major changes or corrections needed. Well written.

Turbulent Heat Transfer and Friction in Four-Wall Convergent/Divergent Square Channels with One Ribbed Wall (한면에 리브가 설치된 4벽면 수축/확대 채널의 난류 열전달과 유체마찰)

  • Ahn, Soo Whan;Lee, Myung Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.10
    • /
    • pp.773-778
    • /
    • 2015
  • The local heat transfer and pressure drop of developed turbulent flows in convergent/divergent channels with square axial cross-sectional areas were experimentally investigated to improve the channel design, such as a gas turbine cooling system. Square convergent/divergent channels with one ribbed wall were manufactured with a fixed rib height e of 10 mm and a ratio of rib spacing p to height e of 10. The measurement was conducted for Reynolds numbers from 15,000 to 89,000. Convergent, divergent, and straight channels with ratios $D_{ho}/D_{hi}$ of 0.75, 1.33, and 1.0, respectively, are considered. Of the three channel types, the ribbed divergent channel was found to produce the best thermal performance under identical flow rate, pumping power, and pressure loss conditions.