• Title/Summary/Keyword: 루버

Search Result 54, Processing Time 0.025 seconds

A Study on the Flow Analysis of Ventilation Louver for Polar Ship (극지운항 선박용 루버 환기창 유동해석에 관한 연구)

  • Yi, Chung-Seob;Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.16-22
    • /
    • 2018
  • This study is about flow distribution in ventilation systems used in marine louvers. The flow analysis on a louver installed on the vent of a vessel results in the following conclusions: (a) as the velocity of the fluid entering the louver increases, the pressure drop increases; (b) as the pressure drop increases, it tends to increase following a quadratic function. The velocity was confirmed to decrease at the entrance of the louver. This indicates that as the pressure increases, the velocity decreases, and the velocity of the moving fluid is increasing as it passes through the louver vanes.

An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins (복합 전열 촉진 핀이 적용된 핀-관 열교환기의 성능에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4364-4374
    • /
    • 2015
  • In this study, heat transfer and friction characteristics of compound enhanced fin-and-tube heat exchangers were experimentally investigated. Louver-finned heat exchangers were also tested for comparison purpose. The effect of fin pitch on j and f factor was negligible. The j factor decreased as number of tube row increased. However, f factor was independent of number of tube row. Louver fin samples yielded higher j and f factors than compound enhanced fin samples. For one row, j and f factors of louver fin were 23% and 27% higher than those of compound enhanced fin. For two row, those were 11% and 8%, and for three row, those were 10% and 9%. However, heat transfer capacities at the same pressure drop of the compound enhanced fins were 6.4% for one row, 11.1% for two row and 13.6% for three row larger than those of louver fins, Existing louver fin correlation overpredicted the present j factors and underpredicted the present f factors.

An Experimental Study on Air-Side Performance of Fin-and-Tube Heat Exchangers Having Compound Enhanced Fins Under Wet Condition (복합 전열 촉진 핀이 적용된 핀-관 열교환기의 습표면 성능에 대한 실험적 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.5778-5788
    • /
    • 2015
  • In this study, wet surface heat transfer and friction characteristics of compound enhanced fin-and-tube heat exchangers were experimentally investigated. Louver-finned heat exchangers were also tested for comparison purpose. The effect of fin pitch on j and f factor was negligible. Both j and f factor decreased as number of tube row increased. Compound enhanced fin samples yielded higher j and f factors than louver fin samples. For one row, j and f factors of compound enhanced fin samples were 11% and 43% higher than those of louver fin samples. For two row, those were 8% and 50%, and for three row, those were 17% and 53%. Heat transfer capacities at the same pressure drop of the compound enhanced fin samples were 2.0% for one row, 3.1% for two row and 8.4% for three row larger than those of louver fin samples, Data were compared with predictions of existing louver fin correlations.

An Experimental Study on the Airside Performance of Fin-and-Tube Heat Exchangers Having Wide Louver Fin (광폭 루버 핀이 장착된 핀-관 열교환기의 공기측 전열 성능에 관한 실험적 연구)

  • Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.254-262
    • /
    • 2015
  • Heat transfer rate can be increased by increasing the heat transfer area. In this study, wide louver fin-and-tube heat exchangers with $P_t/P_l=1.03$ were tested and compared with louver fin-and-tube heat exchanger with $P_t/P_l=0.6$. Results show that heat transfer capacities of wide louver samples are larger (9.8% at one row, 13.6% at two row and 4.1% at three row) than those of conventional louver samples. Considering the area ratio of 1.78, the increase of heat transfer capacity is rather small, possibly due to the smaller heat transfer coefficient and fin efficiency of the wide louver sample. The j factor of the louver fin was 67% larger at one row, 42% larger at two row and 52% larger at three row. The f factor of the louver fin was 81% larger at one row, 63% larger at two row and 60% larger at three row. The effect of fin pitch on j and f factors are not pronounced and the j factor decreased as the number of tube row increased.

Improvement for Natural Ventilation Flow inside a Large Factory Building Using Louver-t ype Ventilator (루버를 이용한 대형공장 내부 자 연환기유동 개선에 관한 연구)

  • Kang, Jong-Hoon;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.705-706
    • /
    • 2008
  • When heat generated inside a large factory building is not discharged due to a stagnant flow, the working environment of workers becomes worse and the cooling of high-temperature products such as hot-rolling coils is delayed. To investigate the natural ventilation inside a large factory building, experimental studies were carried out using wind-tunnel tests. The scale-down factory building models were placed in an atmospheric boundary layer (ABL) and the mean and fluctuating velocity fields were measured using a particle image velocimetry (PIV) technique. For the prototype factory model, the outdoor air is only entrained into the factory building through the one-third open windward wall, and stagnant flow is formed in the rear part of the target area. In order to improve the indoor ventilation environment of the factory building, three different louver-type ventilators were attached at the upper one-third open windward wall of the factory model. Among the three louver ventilators tested in this study, the ventilator model #3 with the outer louver (${\theta}_o$ = 90$^{\circ}$) and the inner louver (${\theta}_i$ = -70$^{\circ}$) was found to improve the natural ventilation inside the factory building model effectively. The flow rate of the entrained air was increased with aligning the outer louver blades with the oncoming wind and guiding the entrained air down to the ground surface with elongated inner louver blades.

  • PDF

Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser (사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구)

  • Jang, Heon-Deock;Lee, Dae-Hui;Lee, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.683-687
    • /
    • 2012
  • The purpose of this paper is to numerically study the characteristics of the indoor air flow of a square ceiling type diffuser according to the vane angle and flow rate. The CFX of ANSYS 13.0 was used for the CFD tool. The size of the room is $6m(X){\times}6m(Y){\times}2.7m(Z)$. The exhaust diffuser was positioned diagonally to the supply diffuser. This diffuser was designed to have many holes, so the air supply had long throw patterns with low velocity decay. The characteristics of the indoor air flow was studied at volume flow rates of 5.1 CMM and 7.4 CMM, and a vane angle from $30^{\circ}$ to $60^{\circ}$, every $10^{\circ}$.

Numerical Analysis on the Heat Transfer Enhancement by Modified Lovour Fin (개량 루버핀에 의한 열전달 성능향상에 관한 연구)

  • Chung, Jae-Dong;Park, Byung-Kyu;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.408-413
    • /
    • 2001
  • Numerical analysis on the three-dimensional laminar flows (Re=1000) and heat transfer in a rectangular channel with punched longitudinal vortex generator have been conducted to explore the heat transfer enhancement and the combined effect of the angle of attack ${\alpha}$ and the lovour angle ${\beta}$. Rectangular winglets have been used as vortex generators. Velocity and temperature fields and spanwise averaged Nu and friction factor were presented. Enhancement of heat transfer and flow loss penalty are evidenced. The results show performance characteristics allowing a reduction in heat transfer surface area of 62% for fixed heat duty and for fixed pumping power compared with that of channel flow without vortex generator. However, adding lovour angle to the vortex generator shows no positive effect on the heat transfer enhancement.

  • PDF

Improvement of Natural Ventilation in a Factory Building Using PIV Technique (PIV 풍동실험을 통한 공장건물의 자연환기 향상 연구)

  • Kang Jong-Hoon;Lee Snag-Jeon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.46-49
    • /
    • 2005
  • Vents at outer walls of a large factory building are very important for natural ventilation. But, if a full-open vent is used, rain comes through the vents. We tried to utilize the natural ventilation effectively using a louver. A 1/120 scale-down building model was placed inside an atmospheric boundary layer simulated in a wind tunnel test section. The effect of louver angle on the ventilation flow inside the factory building was investigated experimentally. Instantaneous velocity fields inside the building model were measured using a 2-frame PIV system with varying the louver angles ($\theta=20^{\circ},\;40^{\circ},\;60^{\circ}$). For the case of $\theta=60^{\circ}$, as the incoming flow into the factory building increases, the inside velocity distribution becomes uniformly.

  • PDF

Technique Development Tendency for Ice Class Louver (아이스 클래스(Ice-Class)루버의 기술개발 동향)

  • Seo, Kwang-Oog;Shim, Eui-Bo;No, Byeang-Su;Cho, Dae-Hwan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2015.07a
    • /
    • pp.41-42
    • /
    • 2015
  • 극해 지역은 채굴가능 매장량의 30% 정도의 각종 천연자원이 매장되어 있으며 기후변화로 인해 북극해 항로를 이용한 운항 및 자원의 수송과 저장을 위해 빙해 선박과 극지용 해양구조물의 수요가 증가하고 있다. 이 연구에서는 아이스 클라스 등 방한기술에 근거하여 빙해 선박에 탑재되는 루버의 기술개발 동향에 대해 고찰 하였다.

  • PDF