• Title/Summary/Keyword: 로온도

Search Result 9,458, Processing Time 0.05 seconds

열처리 온도에 의한 디지털 합금 InGaAlAs 다중양자우물의 발광특성 변화

  • Jo, Il-Uk;Byeon, Hye-Ryeong;Ryu, Mi-Lee;Song, Jin-Dong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.414-414
    • /
    • 2013
  • InGaAlAs/InP은 $1.3{\sim}1.55{\mu}m$ 레이저 다이오드 응용을 위한 InGaAsP/InP를 대체하기 위한 물질로 많은 관심을 받아왔다. 디지털 합금 InGaAlAs 다중양자우물(multiple quantum wells: MQWs) 시료는 MBE (molecular beam epitaxy) 장비를 이용하여 n-InP 기판 위에 성장하였다. 양자우물과 장벽은 각각 (InGaAs)0.8(InAlAs)0.2와 (InGaAs)0.4(InAlAs)0.6 SPSs (short-period superlattices)로 $510^{\circ}C$에서 성장하였다. 발광특성을 향상시키기 위하여 질소분위기에서 $700^{\circ}C$ $750^{\circ}C$ 또는 $800^{\circ}C$에서 30초간 열처리(rapid thermal annealing: RTA)하였다. RTA 온도에 따른 디지털 합금 InGaAlAs MQWs의 발광특성을 분석하기 위해 PL (photoluminescence)과 TRPL(time-resolved PL)을 이용하였다. RTA 온도에 따른 InGaAlAs MQWs 시료의 발광 메카니즘 및 운반자 동력학을 연구하기 위하여 발광파장 및 온도에 따른 TRPL을 측정하였다. 저온(10 K)에서 PL 피크는 RTA 온도를 $700^{\circ}C$에서 $750^{\circ}C$로 증가하였을 때 1,242 nm에서 1,245 nm로 장파장 영역으로 이동하였다가 $800^{\circ}C$에서 열처리하였을 때 단파장 영역으로 이동하여 1,239 nm에서 나타났다. 또한 PL 세기는 RTA 온도를 증가함에 따라 증가함을 보이다가 RTA 온도를 $800^{\circ}C$로 증가하였을 때 PL 세기는 감소하였다. 발광소자 개발을 위한 InAlGaAs MQWs 시료의 최적의 열처리 조건을 이러한 PL과 TRPL 결과로부터 결정할 수 있다.

  • PDF

Change Point Detection of Heating Furnace Status using IoT Sensor Data (IoT 센서 데이터를 이용한 가열로 상태 변경 지점 감지 알고리즘)

  • Choi, Jeonghoon;Kim, Seyoung;Ryu, Kwang-Ryel
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.746-749
    • /
    • 2019
  • 자유 단조는 고온에 가열한 강괴에 높은 압력을 가하여 원하는 형상의 제품을 만드는 공정으로 에너지 소모가 매우 크다. 여러 개의 강괴를 가열로에 장입하여 고온에 가열한 후 소재를 하나씩 꺼내어 프레스 공정을 수행한다. 가열로에 함께 장입되는 소재들의 조합에 따라 가열 시 소요 시간 및 에너지 사용량이 달라진다. 소재 조합에 따른 가열 비용 예측을 통해 최적의 소재 조합을 결정하여 에너지 효율을 높일 수 있다. 비용 예측 모형을 학습하기 위해서는 가열 소요 시간 및 에너지 사용량 데이터가 필요하다. 따라서 본 논문에서는 가열로의 온도 및 가스 사용량 데이터를 이용하여 가열로의 가동 상태 변경 지점을 감지하는 방안을 제안한다. 가열로의 온도 및 가스 사용량은 IoT 인프라를 기반으로 손 쉽게 획득할 수 있다. 가열로의 상태 별로 온도 및 가스 사용량에 나타나는 패턴을 이용하여 상태 변경 지점을 감지한다. 이를 통해 가열 공정 데이터를 획득할 수 있을 뿐만 아니라 가열로의 상태를 실시간에 모니터링이 가능함으로써 불필요하게 가열하는 것을 예방하여 에너지 효율을 높일 수 있다.

전동기의 열회로계산

  • 김방광;최진원
    • 전기의세계
    • /
    • v.30 no.12
    • /
    • pp.761-763
    • /
    • 1981
  • Computer의 도움으로 복잡한 선형회로망의 해석이 숩게 되자, 전기기계의 열회로에 관한 연구와 실험이 많은 전기기계 Maker에 의해서 수행되어 지고 있다. 열회로라는 것은 각 부분의 온도를 전위(potential)로 보고, 발열체는 current source 로 보아, 온도차에 의해서 열이 전달되는 현상을 전위차(전압)에 의해서 전류가 흐르는 회로로 변환한 것을 말하는 데 전동기에 있어서의 열특성은 열저항과 열용량으로 계산되어 지고 있다.

  • PDF

A Study On Temperature Control Of A Glass Melting Furnace Using Fuzzy Logic (퍼지 로직을 이용한 유리 용해로 온도 제어에 관한 연구)

  • Moon, Un-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2920-2922
    • /
    • 1999
  • 본 논문에서는 유리 용해로의 온도 제어 문제에 있어서, 퍼지 이론의 응용 방식을 제시한다. 유리용해로의 동특성을 분석하고, 이에 적합하도륵 기존 고전적인 제어기와 퍼지 로직을 결합하는 알고리듬을 제시한다. 제시된 제어기는 실제 용해로의 생산공정에 효율적으로 적용되었다.

  • PDF

A Property Analysis on Spatial Distribution of Sea Water Temperature Difference for Site Selection of Ocean Thermal Energy Conversion Plant (해양온도차 발전소의 입지선정을 위한 해수 온도차의 공간적 분포특성 분석)

  • 서영상;장이현;조명희
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.567-575
    • /
    • 1999
  • This study found potential ability to generate electric power using difference in water temperature between sea surface water and deep water in the East Sea which includes the East Sea Proper Water with the temperature less than 1$^{\circ}C$ throughout a year without seasonal variation. To quantify the difference in water temperature between sea surface water and deep water in the East Sea. We computed the annual mean ($^{\circ}C$), the annual amplitude ($^{\circ}C$), the annual phase (degree) and the duration time which showed more than 15$^{\circ}C$ temperature difference from the water temperature data using Harmonic analysis during 1961~1997. The best place for generating electric power in the East Sea seems to be the eastward ocean areas (36$^{\circ}$ 05'N, 129$^{\circ}$ 48'E~36$^{\circ}$ 05'N, 130$^{\circ}$ 00E'E) from Pohang city. The annual mean of the difference in water temperature between sea surface water and 500 m depth was 24$^{\circ}$C at the place to generate electric power in August according to the data of 1961~1997. the maximum duration periods with more than 15$^{\circ}C$ temperature difference were 215 days (5/5-12/10) a year in the place mentioned electricity with a stable plan. In the East Sea coastal areas of the Korean peninsula, the average minimum depth to reach the East Sea Proper Water from surface water is 300 m and fluctuates between 250 m and 350 m throughout a year. Further studies could be needed for the utilization of cold water, such as the East Sea Proper Water for energy conversion.

  • PDF

An First Order Approximiate Analytical Solution to Predict Qualitative Performance Characteristics of Stirling Enging (Stirling기관(機關)의 성능예측(性能豫測)을 위한 1차원(次元) 근사해석(近似解析))

  • Kim, Tae Han
    • Current Research on Agriculture and Life Sciences
    • /
    • v.9
    • /
    • pp.87-94
    • /
    • 1991
  • An approximate analytical method to predict performance characteristics of the stirling engines in a preliminary design stage was investigated. In basic equations proposed by walker, typical temperatures of working fluids in expansion and compression spaces were treated the same as those of working fluids in heater and cooler respectively. While the temperature of working fluids in the expansion space was actually lower than that of working fluids in the heater, the temperature of working fluids in the compression space was higher than that of working fluids in the cooler. The aim of this study divided typical temperatures of working fluids in expansion and compression spaces into serval grades, and than evaluated the experimental engine. As the result, the case which working fluids temperature of expansion space was treated as lower than the heater temperature and which that of compression space was treated as higher than the cooler temperature, was much closer to the experimental value.

  • PDF

Development of Temperature Controlled Impulse Sealer for Preventing Cumulative Heat and Improving Sealing Quality (누적열 방지 및 비닐 접착품질 향상을 위한 온도 제어형 임펄스 씰러 (Impulse Sealer)의 개발)

  • Kim, Insoo;Kim, Sung Min;Seo, Jongchul
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.117-123
    • /
    • 2019
  • The general Impulse Sealer has a problem of sealing quality because continuously sealing process results in an undesirable temperature rise, which may accumulate the heat during the operation. In order to address such a drawback, the controlled sealing temperature method can be effectively utilized compared with the general controlled time method. As such, a temperature sensor with capability of detecting the sealing temperature was installed, and a separate PCB was manufactured to control the sealing temperature by measuring and calculating the detected temperature. The temperature changes during the temperature rise and maximum temperature after continuously operation were investigated using an Impulse Sealer system. Next, the results obtained from experiment were compared with each other. As such, the maximum temperature was 70.3℃, whereas 8.9℃ was recorded as control temperature. It implies that this controlled temperature system prevented the undesirable temperature rise, thereby causing a consistent sealing quality.

The Survey of Cold Storage Temperature and Determine of Appropriate Statistics Probability Distribution Model (국내 식품냉장창고 온도분포 분석 및 적정 확률분포모델 설정)

  • Kim, Hyong-Tae;Kim, Sang-Kyu;Behk, Ok-Jin;Bahk, Gyung-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.312-316
    • /
    • 2012
  • This study was to present the proper probability distribution models that based on the data for surveys of food cold storage temperatures as the input variables to the further MRA (Microbial risk assessment). The temperature was measured by directly visiting 7 food plants. The overall mean temperature for food cold storages in the survey was $2.55{\pm}3.55^{\circ}C$, with 2.5% of above $10^{\circ}C$, $-3.2^{\circ}C$ and $14.9^{\circ}C$ as a minimum and maximum. Temperature distributions by space-locations was $0.80{\pm}1.69^{\circ}C$, $0.59{\pm}1.68^{\circ}C$, and $0.65{\pm}1.46^{\circ}C$ as an upper (2.4~4 m), middle (1.5~2.4 m), and lower (0.7~1.5 m), respectively. Probability distributions were also created using @RISK program based on the measured temperature data. Statistical ranking was determined by the goodness of fit (GOF) to determine the proper probability distribution model. This result showed that the LogLogistic (-4.189, 5.9098, 3.2565) distribution models was found to be the most appropriate for relative MRA conduction.

Quality Characteristics of Ssangwha Extract according to Extraction Conditions (쌍화추출물의 추출조건에 따른 품질특성에 관한 연구)

  • Park Sang-Soon;Lee Keun-Bo;Han Myung-Kyu
    • The Korean Journal of Food And Nutrition
    • /
    • v.17 no.4
    • /
    • pp.368-373
    • /
    • 2004
  • Optimal extraction conditions were established from the difference of quality characteristics according to extraction conditions of Ssangwha extracts(SWE). Extract yields of SWE obtained from the established extraction conditions were as follows. The maximum yield was 48.90% at extraction temperature 90$^{\circ}C$ and alcohol concentration 50%, extraction yield and alcohol concentration of extraction solvent was proportioned. Increase of extraction yields at extraction temperature 80∼90$^{\circ}C$ and more than alcohol concentration 30% had slowdown tendency according to increase of alcohol concentration. At this view point, the optimum extraction conditions were alcohol concentration 30% and more than extraction temperature 80$^{\circ}C$. In this study, optimal extraction conditions of SWE were extraction temperature 90$^{\circ}C$ and alcohol concentration 30%.

Temperature variation due to ultrasonic absorption in protein (초음파 흡수에 의한 단백질에서의 온도 변화 특성)

  • 신동욱
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.159-164
    • /
    • 1993
  • 초음파 흡수에 의한 단백질에서의 온도 변화 특성을 관측하기 위하여, 간단한 조직의 형태인 계란 흰자와 계란 흰자의 주성분인 물과 알부민 수용액을 시료로 선택하여, 초음파 흡수에 의한 온도 변화 특성을 물리 음향학적으로 관측하였다. 수 MHz의 초음파를 집속형 변환기에서 연속파의 형태로 시료에 투사하였을 때, 한정된 시료에서의 온도 변화를 측정하였다. 측정결과, 물과 알부민 성분에 의한 온도 증가 효과는 미미함을 알 수 있었다. 초음파 흡수에 의한 계란 흰자에서의 온도 변화는 단백질의 주성분인 알부민에 의한 효과보다는, 단백질을 구성하고 있는 각 성분들의 결합에 의한 효과가 큼을 알 수 있다. 이들 결과에 대한 이론적 검토로부터 초음파 흡수에 의한 인체내 온도 변화 및 부작용에 대한 초음파 강도의 안전기준의 토대 마련이 가능함을 제시하였다.

  • PDF