• Title/Summary/Keyword: 로그격자

Search Result 8, Processing Time 0.018 seconds

Improved efficiency of numerical modeling using the expanding domain method with a logarithmic grid (영역확장법 및 로그격자를 이용한 수치모델링 효율 향상 연구)

  • Hong, Bo-Ram;Bae, Ho-Seuk;Ha, Wan-Soo;Chung, Woo-Keen
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.75-80
    • /
    • 2016
  • Numerical modeling based on the finite difference method has been widely used with improved computer technology. However, high-capacity computing resources are required for this technique. To overcome this limitation, we propose an algorithm the employs a logarithmic grid in conjunction with the expanding domain method. The proposed algorithm was verified through comparison with numerical results obtained with a conventional method. The results confirmed that our algorithm can improve computational efficiency.

Design of improved Janus system based on the threshold cryptographic scheme (임계 암호 기법에 기반한 개선된 야누스 시스템의 설계)

  • 심미선;양종필;이경현
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.11a
    • /
    • pp.150-153
    • /
    • 2003
  • 지속적으로 증가하고 있는 웹사이트는 사용자마다 유일한 신분확인정보(ID, 패스워드)를 요구 한다. 이 때 사용자는 웹사이트마다 별개의 계정을 만드는 것이 공격자의 위협으로부터 안전하지만, 현실적으로 사용자의 기억의 한계, 편의 추구로 인해 한 사용자가 사용하는 계정의 가짓수는 한정되기 마련이다. 따라서, 어느 공격자가 단일 사용자의 특정 웹사이트에 대한 ID와 패스워드를 알게되면, 기공격자는 다른 웹사이트에 동일한 ID와 패스워드를 사용한 로그인 시도 공격이 성공할 확률이 매우 높다고 할 수 있다. 본 논문에서는 이러한 사용자 ID와 패스워드에 대한 문제점을 해결하기 위한 방안으로서 사용자는 로그인하려는 웹사이트에 상관없이 항상 동일한 ID와 패스워드를 사용하지만, 실질적으로는 사용자 머신내에 있는 내부 프록시(proxy)에 의해서 웹사이트마다 독립적이고 유일한 가명ID와 가명 패스워드를 생성하는 방안을 제안한다. 또한 제안 방안에서는 임계 암호 기법을 이용하여 단일 사용자 ID와 패스워드로부터 가명 ID와 가명 패스워드를 생성하는 함수를 안전하게 구성한다.

  • PDF

The Establishment of a High Resolution(1Km×1Km) Wind Energy Map Based on a Statistical Wind Field Model (통계적 바람장모형에의한 고해상도(1Km×1Km)풍력에너지지도 작성에 관한 연구)

  • Kim, Hea-Jung;Kim, Hyun-Sik;Choi, Young-Jean;Byon, Jae-Young
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.6
    • /
    • pp.1157-1167
    • /
    • 2010
  • This paper details a method for establishing a wind energy map having($1Km{\times}1Km$) resolution. The map is essential for measurement and efficiency-testing of wind energy resources and wind site analysis. To this end, a statistical wind field model is estimated that covers 345,682 regions obtained by $1Km{\times}1Km$ lattices made over South Korea. The paper derives various characteristics of a regional wind energy resource under the statistical wind field model and estimates them to construct the wind energy map. Kolmogorov-Smirnov test, based on TMY(typical meteorological year) wind data of 76 weather station areas, shows that a Log-normal model is adequate for the statistical wind field model. The model is estimated by using the wind speed data of 345,682 regions provided by the National Institute of Meteorological Research(NIMR). Various wind energy statistics are studied under the Log-normal wind field model. As an application, the wind energy density(W$/m^2$) map of South Korea is constructed with a resolution of $1Km{\times}1Km$ and its utility for the wind site analysis is discussed.

KpqC 공모전에 제출된 Fiat-Shamir with aborts 구조의 격자 기반 서명 기법 분석

  • 홍가희;우주;박종환
    • Review of KIISC
    • /
    • v.33 no.3
    • /
    • pp.27-37
    • /
    • 2023
  • 양자 컴퓨팅의 발전으로 기존의 전자서명 기법에 사용되던 소인수분해 문제와 이산로그 문제가 다항 시간 내에 풀린다. 그에 따라 국내외에서는 양자 컴퓨팅 환경에서도 안전한 암호 기법에 대한 연구가 활발히 진행되고 있다. 미국 국립 표준 기술 연구소에서 양자 내성 암호 기법의 표준을 설립하고자 Post-Quantum Cryptography Standardization Process를 진행하였으며 전자서명 기법으로는 CRYSTALS-Dilithium, FALCON, SPHINCS+가 표준으로 선택되었다. 국내에서도 양자 내성 암호 표준 수립을 위하여 KpqC 공모전이 개최되었다. 본 논문에서는 KpqC 공모전 Round 1에 제안된 격자 기반 전자서명 기법 중 Dilithium과 같이 Fiat-Shamir with aborts paradigm 구조로 설계된 3개의 기법, HAETAE, GCKSign, NCC-Sign을 분석하고 Dilithium과 함께 비교하였다.

Hydrological Assessment of Multifractal Space-Time Rainfall Downscaling Model: Focusing on Application to the Upstream Watershed of Chungju Dam (멀티프랙탈 시·공간 격자강우량 생산기법의 수문학적 적용성 평가 : 충주댐상류유역 중심으로)

  • Song, Ho Yong;Kim, Dong-Kyun;Kim, Byung-Sik;Hwang, Seok-Hwan;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.959-972
    • /
    • 2014
  • In this study, a space-time rainfall grid field generation model based on multifractal theory was verified using nine flood events in the upstream watershed of Chungju dam in South Korea. For this purpose, KMA radar rainfall data sets were analyzed for the space-time multifractal characteristics. Simulated rainfall fields that represent the multifractal characteristics of observed rainfall field were reproduced using the space-time rainfall grid field generation model with log-Poisson distribution and three-dimension wavelet function. Simulated rainfall fields were applied to the S-RAT model as input data and compared with both observed rainfall fields and low-resolution rainfall field runoff. Error analyses using RMSE, RRMSE, MAE, SS, NPE and PTE indicated that the peak discharge increases about 20.03% and the time to peak decreases about 0.81%.

Experimental Study on the Damping Estimation of the 5×5 Partial Fuel Assembly (5×5 부분핵연료 집합체의 감쇠추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.163-168
    • /
    • 2006
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle $(5\times5)$ which is called partial fuel assembly is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid to obtain the Flow-Induced Vibration (FIV) characteristics of the scaled fuel assembly over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the assembly prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the scaled test assembly. For the damping factor of the partial fuel assembly and the grid cage at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the partial fuel assembly is about $0.7\%$ with reasonable error of $2\%$ for the previous results. Nonlinear behavior of the partial fuel assembly might be stem mainly from the rod-grid support configuration.

Experimental study on the damping estimation of the 5$\times$5 rod bundle (5$\times$5 봉다발의 감쇄추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.503-506
    • /
    • 2005
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle (5$\times$5) is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid like the coolant mixing performance and to obtain the Flow-Induced Vibration (FIV) characteristics of the rod bundle over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the bundle prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the small scaled test bundle. For the damping factor of the rod bundle and the grid case at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the rod bundle is about 0.7% with reasonable error of 2% for the previous results. Nonlinear behavior of the rod bundle might be stem mainly Iron the rod-grid support configuration.

  • PDF

Travel Time Calculation Using Mono-Chromatic Oneway Wave Equation (단일주파수 일방향파동방정식을 이용한 주시계산)

  • Shin, Chang-Soo;Shin, Sung-Ryul;Kim, Won-Sik;Ko, Seung-Won;Yoo, Hai-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.4
    • /
    • pp.119-124
    • /
    • 2000
  • A new fast algorithm for travel time calculation using mono-chromatic one-way wave equation was developed based on the delta function and the logarithms of the single frequency wavefield in the frequency domain. We found an empirical relation between grid spacing and frequency by trial and error method such that we can minimize travel time error. In comparison with other methods, travel time contours obtained by solving eikonal equation and the wave front edge of the snapshot by the finite difference modeling solution agree with our algorithm. Compared to the other two methods, this algorithm computes travel time of directly transmitted wave. We demonstrated our algorithm on migration so that we obtained good section showing good agreement with original model. our results show that this new algorithm is a faster travel time calculation method of the directly transmitted wave for imaging the subsurface and the transmission tomography.

  • PDF