• Title/Summary/Keyword: 레일 온도

Search Result 419, Processing Time 0.024 seconds

Preparation and Characterization of Polysaccharide-based Nanofiber Using Electrospinning Method (전기방사 방법을 이용한 천연 다당류 나노섬유 제조 및 특성 연구)

  • Kim, Se Jong;Lee, Su Jeong;Woo, Chang Hwa;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.26 no.4
    • /
    • pp.318-327
    • /
    • 2016
  • In this study, alginate/poly(ethylene oxide) (PEO), and chitosan/PEO solution are prepared by dissolving alginate and chitosan into specific solvent for electrospinning. Solutions are poured into 10 mL plastic syringes with a metal nozzle supplied a high voltage power. The solution of alginate and chitosan is controlled by polymer concentration, temperature, relative humidity, applied voltage, distance from nozzle and flow rate of solution. Morphologies of fabricated nanofiber are observed by scanning electron microscopy (SEM). Optimal conditions for electrospinning of alginate nanofiber membrane are 2 wt% of alginate, 2 wt% of PEO at $60^{\circ}C$, 15 cm from the nozzle, $8{\mu}m/min$ flow rate and 20~24 kV. The conditions for elctrospinning of chitosan nanofiber membrane are 2 wt% of chitosan, 2 wt% PEO at $25^{\circ}C$, 15 cm from the nozzle, $8{\mu}m/min$ flow rate and 24 kV. The fabrication conditions of complex nanofiber prepared with chitosan and alginate are 20 cm from the nozzle, $8{\mu}m/min$ flow rate and 26 kV.

Preparation and Characterization of Hydrophilic Aminated poly(styrene-ethylene-butylene-styrene) Polymer Membrane (친수성 아민화된 poly(styrene-ethylene-butylene-styrene) 고분자 분리막 제조 및 투습도 특성평가)

  • Son, Tae Yang;Kim, Ji Hyun;Park, Chi Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.336-343
    • /
    • 2017
  • These days, the quality of indoor air is a very important concept for modern people who have lived in building and is a matter of new thinking. The quality is determined by the temperature and humidity of indoor air. In addition, there is a disadvantage in that energy consumption is severe for indoor air improvement. Therefore, researches on methods to solve such problems using total heat exchange have been actively conducted. So, in this study, aminated poly(styrene-ethylene-butylene-styrene) polymers were synthesized by introducing a hydrophilic substituent, ammonium, into main chain and the properties of synthesized polymers were evaluated. The synthesis was carried out through chloromethylation and amination reactions to introduce ammonium into main chain. As a result, the water uptake and the ion exchange capacity of the synthesized polymers increased as the content of the reaction reagent solution increased. It was confirmed that the important data at the total heat exchange membrane, water vapor transmission rate also increased according to temperature, equivalent.

PreSPI: Design and Implementation of Protein-Protein Interaction Prediction Service System (PreSPI:단백질 상호작용 예측 서비스 시스템 설계 및 구현)

  • Kim, Hong-Soog;Jang, Woo-Hyuk;Lee, Sung-Doke;Han, Dong-Soo
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2004.11a
    • /
    • pp.86-100
    • /
    • 2004
  • 계산을 통한 단백질 상호작용 예측 기법의 중요성이 제기되면서 많은 단백질 상호 작용 예측 기법이 제안되고 있다. 하지만 이러한 기법들이 일반 사용자가 손쉽게 사용할 수 있는 서비스 형태로 제공되고 있는 경우는 드물다. 본 논문에서는 현재까지 알려진 단백질 상호작용 예측 기법 중 예측 기법의 완성도가 높고 상대적으로 예측 정확도가 높은 것으로 알려진 도메인 조합 기반 단백질 상호 작용 예측 기법을 PreSPI(Prediction System for Protein Interaction)라는 서비스 시스템으로 설계하고 구현하였다. 구현된 시스템이 제공하는 기능은 크게 도메인 조합 기반 단백질 상호 작용 예측 기법을 서비스 형태로 만들어 제공하는 기능으로 입력 단백질 쌍에 대한 상호작용 예측이 중심이 된 핵심기능과, 핵심 기능으로부터 파생되는 기능인 부가 기능, 그리고 주어진 단백질에 대한 도메인 정보검색 기능과 같이 단백질 상호작용에 관하여 연구하는 연구자에게 도움이 되는 일반적인 기능으로 구성되어 있다. 계산을 통해 단백질 상호 작용을 예측하는 시스템은 대규모계산이 요구되는 경우가 많아 좋은 성능을 갖추는 것이 중요하다. 본 논문에서 구현된 PreSPI 시스템은 서비스에 따라 적절히 그 처리를 병렬화 함으로써 시스템의 성능 향상을 도모하였고, PreSPI 가 제공하는 기능을 웹 서비스 API 로 Deploy 하여 시스템의 개방성을 지원하고 있다. 또한 인터넷 환경에서 변화되는 단백질 상호 작용 및 도메인에 관한 정보를 유연하게 반영할 수 있도록 시스템을 계층 구조로 설계하였다. 본 논문에서는 PreSPI 가 제공하는 몇 가지 대표적인 서비스에 관하여 사용자 인터페이스를 중심으로 상술함으로써 초기 PreSPI 사용자가 PreSPI 가 제공하는 서비스를 이해하고 사용하는 데에도 도움이 되도록 하였다.있어서 자각증상, 타각소견(他覺所見)과 함께 이상(異常)은 확인되지 않았으며 부작용도 없었다. 이상의 결과로부터, ‘펩타이드 음료’는 경증고혈압 혹은 경계역고혈압자(境界域高血壓者)의 혈압을, 자각증상 및 혈액${\cdot}$뇨검사에도 전혀 영향을 미치지 않고 저하시킨다고 결론지었다.이병엽을 염색하여 흰가루 병균의 균사생장과 포자형성 등을 관찰한 결과 균사가 용균되는 것을 볼 수 있었으며, 균사의 용균정도와 분생포자형성 억제 정도는 병 방제효과와 일치하는 경향을 보였다.을 의미한다. IV형은 가장 후기에 포획된 유체포유물이며, 광산 주변에 분포하는 석회암체 등의 변성퇴적암류로부터 $CO_{2}$ 성분과 다양한 성분의 유체가 공급되어 생성된 것으로 여겨진다. 정동이 발달하고 있지 않으며, 백운모를 함유하고 있는 대유페그마타이트는 변성작용에 의한 부분용융에 의해 형성된 멜트에서 결정화되었으며, 상당히 높은 압력의 환경에서 대유페그마타이트의 결정화작용 과정에서 용리한 유체의 성분이 전기석에 포획되어 있다. 이때 용리된 유체는 다양한 성분을 지니고 있었으며, 매우 낮은 공융온도와 다양한 딸결정은 포유물 내에 NaCl, KCl 이외에 적어도 $CaCl_{2},\;MgCl_{2}$와 같은 성분을 포함하고 있음을 지시한다. 유체의 용리는 적어도 $2.7{\sim}5.3$ kbar 이상의 압력과 $230{\sim}328^{\circ}C$ 이상의 온도에서 시작되었다.없었다. 결론적으로 일부 한방제와 생약제제는 육계에서 항생제를 대체하여 사용이 가능하며 특히 혈액의 성분에 유의한 영향을 미치는 것으로 사료된다. 실증연구가 필요할 것으로 사료된다.trip과 Sof-Lex disc로 얻어진 표면은 레진전색제의 사용으로 표면조도의 개선

  • PDF

Recovery of $SF_6$ from Gas Mixtures with Low Concentration of $SF_6$ (저농도 $SF_6$ 기체혼합물로부터 $SF_6$의 회수)

  • Lee, Hyun-Jung;Lee, Hyun-Kyung;Choi, Ho-Sang;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.256-262
    • /
    • 2011
  • This study describes the performance of PSF and PC membranes for separation and recovery of $SF_6$ from gas mixtures (10% $SF_6$/70% $N_2$/19% $O_2$/1% $CF_4$) containing low concentration of $SF_6$. The $SF_6$ concentration in retentate, recovery efficiency and selectivity of mixed gases were measured as a function of retentate flow rate and temperature. The concentration of $SF_6$ in the gas recovered from PSF and PC membrane respectively decreased with increase of retentate flow rate and increased with increase of temperature. The values of $SF_6$ concentration in retentate of PSF membrane were higher than those of PC membrane at constant experimental conditions. The maximum value of recovery efficiency of PSF and PC membranes are 95.9% and 67.8%, respectively, under 298.15 K and 150 cc/min of retentate flow rate. With the exception of $CF_4/SF_6$, the real selectivities of $N_2/SF_6$ and $O_2/SF_6$ at PSF membrane were higher than those of PC membrane.

Effect of Water-back-flushing Time and Period in Advanced Water Treatment System by Ceramic Microfiltration (세라믹 정밀여과에 의한 고도정수처리 시스템에서 물 역세척 시간 및 주기의 영향)

  • Park, Jin-Yong;Lee, Hyuk-Chan;Cho, Jae-Hyeong
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.26-34
    • /
    • 2008
  • In this study, periodic water-back-flushing using permeate water was performed to minimize membrane fouling and to enhance permeate flux in advanced water treatment system by ceramic microfiltration. We investigated effect of water-back-flushing period (FT) and time (BT), and tried to find the optimal operating conditions. BT was fixed at 3 sec and FT was changed in $30{\sim}120$ sec to inspect effect of FT. Also, FT was fixed at 120 sec and BT was changed as $3{\sim}12$ sec at experiment of BT effect. At both two experiments, TMP was fixed at 1.52 bar, water-back-flushing pressure at 0.98 bar, feed flow rate at 0.5 L/min, and feed water temperature at $20^{\circ}C$. As the result, optimal FT was 30 sec at fixed BT 3 sec in our experimental range. It means that the more frequent back-flushing was the more effective to reduce membrane fouling. However, there were not large effects of FT due to a short BT. Then, increasing BT at fixed FT 120 sec could decrease resistance of membrane fouling ($R_f$) and increase permeate flux (J) and dimensionless permeate flux ($J/J_o$), and the most total permeate volume ($V_T$) could be produced at the maximum BT 12 sec.

The Study on Optimum Operation Conditions of Ceramic MF Membrane Process in Y Water Treatment Plant (Y 정수장 세라믹막 여과공정 최적 운영인자 평가)

  • You, Sang-Jun;Ahn, Hyo-Won;Park, Sung-Han;Lim, Jae-Lim;Hong, Sung-Chul;Yi, Pyong-In
    • Membrane Journal
    • /
    • v.24 no.3
    • /
    • pp.201-212
    • /
    • 2014
  • This study was performed to discover the optimum operation conditions for the advanced water treatment using the ceramic membrane, introduced the first in the nation at the Y water treatment plant (WTP). The result of investigation to find the optimum operation conditions which can continue preserving the filtration performance as well as satisfying both the economics and the water quality is as follows. In the ordinary water quality condition of the Y WTP, the optimum filtration time(the backwash period), which can minimize the production of backwash waste and preserve the membrane performance was examined to be 4.0 hours on basis of institution capacity ($16,000m^3/day$). Examining the recovery rate of TMP from the chemical cleaning (CIP) discovered that the inorganic contaminants, which cause membrane fouling, such as iron, manganese, aluminum, were removed through the acidic cleaning using citric acid, whereas the membrane recovery rate was found to be low. But, on the other hand, the TMP was recovered to the initial value from the alkali cleaning using the NaOCl. Therefore, the main contaminant causing the fouling was determined to be hydrophilic organic compound( biopolymer). The membrane recovery rate is highly influenced by the temperature of the cleaning chemical. That is, the rate increased with increasing temperature.

Surface Modification of Poly(vinylidene fluoride) Membranes using Surface Modifying Macromolecules (SMMs) and Their Application to Pervaporation Separation (SMMs을 이용한 고분자막의 표면개질과 이의 투과증발분리 연구)

  • Rhim, Ji-Won;Lee, Byung-Seong;Kim, Dae-Hoon;Lee, Bo-Sung;Yoon, Seok-Won;Im, Hyeon-Soo;Moon, Go-Young;Nam, Sang-Yong;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.206-213
    • /
    • 2008
  • Poly(vinylidene fluoride) (PVDF) membrane surfaces were modified using surface modifying macromolecules (SMMs). The Zonyl BA-L as SMM was used and the various PVDF membranes containing 0 to 2 wt% SMM were prepared. The resulting membranes were characterized through SEM, contact angle measurements and pervaporation separation of water-ethanol system. SMM layers were created in the surface regions of PVDF membranes by SEM images and the contact angles were increased more than untreated PVDF membranes. The pervaporation was carried out at 50, 60 and $70^{\circ}C$, and the PVDF membranes containing 1 and 2 wt% SMM were used for 10, 20, 50 wt% water in the binary water/ethanol mixtures and pure water. PVDF/2 wt% Zrlnyl BA-L membrane showed the permeability 5.3 $g/m^2hr$ and separation factor 287 at $50^{\circ}C$ for water : ethanol = 10 : 50 solution.

Characterization of Gas Permeation Properties of Polyimide Copolymer Membranes (공중합체 폴리이미드를 이용한 기체분리막의 특성평가)

  • Lee, Jung Moo;Lee, Myeong Geon;Kim, Se Jong;Koh, Hyung Chul;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.223-230
    • /
    • 2015
  • We synthesized novel polyimides with high gas permeability and selectivity for application of gas separation membrane. 2,2-bis(3,4-carboxylphenyl) hexafluoropropane dianhydride (6FDA) and two kinds of amines with high permeability and solubility were used to prepare the novel polymide. 2,4,6-Trimethyl-1,3-phenylenediamine (DAM) was used to improve gas permeability and 4,4-Methylenedianiline was used to improve the gas selectivity respectively. The polyimide copolymers were synthesized by commercial chemical imidization method using Triethylamine and Acetic anhydride and their average molecular weights were over 100,000 g/mol. The glass temperature (Tg) and the thermal degradation temperature were characterized using differential scanning calorimeter (DSC) and thermogravimetric analysis (TGA). The synthesized copolymers showed high Tg over $300^{\circ}C$ and high thermal degradation temperature over $500^{\circ}C$. The gas permeation properties were measured by time-lag equipment. Although general polyimides showed very low gas permeability, synthesized polyimide copolymer showed high $O_2$ permeability of 10.1 barrer with high $O_2/N_2$ selectivity around 5.3. From this result, we confirm that these membranes have possibility to apply to gas separation membrane.

Preparation of Superflux Nickel Capillary Support with 3D Macropore Channel Network For Gas Separation and Liquid Filtration Membranes (기체/액체 분리막을 위한 3차원 Macropore 채널을 갖는 Superflux 니켈 모세관 지지체의 제조)

  • Song, Ju-Seob;Cho, Churl-Hee
    • Membrane Journal
    • /
    • v.28 no.3
    • /
    • pp.214-219
    • /
    • 2018
  • In the present study, superflux nickel capillary supports for gas and vapor separation membranes were prepared by a combined process of NIPS and sintering. Nickel capillary precursors were prepared by NIPS process from PSf-Ni-DMAC-PEG400 dope solution and was sintered at various temperatures in $H_2$ atmosphere to reliably produce Ni capillary support. The optimized Ni capillary support has an outer and inner diameters of 722 and $550{\mu}m$, and its thickness was $94{\mu}m$. It has 3-dimensional pore channel network and its porosity and mean pore diameter was 26% and $4{\mu}m$, respectively. Also, its mechanical strength was tested in tensile mode: its fracture load was 2.84 kgf and the fracture elongation was 13%. Finally, its single gas permeance was measured: He, $N_2$, $O_2$, and $CO_2$ permeance was 432,327, 281,119, 264,259, and 193,143 GPU, respectively. The superflux behavior could be explained from viscous flow through the macropores having a diameter of $4{\mu}m$ and narrow thickness. It could be concluded that the superflux behavior of the Ni capillary support was from the 3-D pore channel network and the small thickness.

Chromel-Alumel Thermoelectric Flow Sensor Fabricated on Dielectric(Si3N4/SiO2/Si3N4) Membrane (유전체(Si3N4/SiO2/Si3N4)멤브레인 위에 제작된 크로멜-알루멜 열전 유량센서)

  • Lee, Hyung-Ju;Kim, Jin-Sup;Kim, Yeo-Hwan;Lee, Jung-Hee;Choi, Yong-Moon;Park, Se-Il
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.103-111
    • /
    • 2003
  • A chromel-alumel thermoelectric flow sensor using $Si_3N_4/SiO_2/Si_3N_4$ thermal isolation membrane was fabricated. Temperature coefficient of resistance of thin film Pt-heater was about $0.00397/^{\circ}C$, and Seebeck coefficient of chromel-alumel thermocouple was about $36\;{\mu}V/K$. The sensor showed that thermoelectric voltage decreased as thermal conductivity of gas increased, and $N_2$-flow sensitivity increased as heater voltage increased or the distance between heater and thermocouple decreased. When heater voltage was about 2.5 V, $N_2$-flow sensitivity and thermal response time of the sensor were about $1.5\;mV/sccm^{1/2}$ and 0.18 sec., respectively. Linear range in flow sensitivity of the flow sensor was wider than that of Bi-Sb flow sensor.