• Title/Summary/Keyword: 레이저진단

Search Result 134, Processing Time 0.028 seconds

Development of Diagnostic Expert System for Machining Process Ffailure Detection (가공공정의 이상상태진단을 위한 진단전문가시스템의 개발)

  • Yoo, Song-Min;Kim, Young-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.147-153
    • /
    • 1997
  • Fault diagnosis technique in machining system which is one of engineering techniques absolutely necessary to automation of manufacturing system has been proposed. As a whole, diagnosis process is explained by two steps: sensor data acquisition and reasoning current state of system with the given sensor data. Flexible disk grinding process implemented in milling machine was employed in order to obtain empirical manufacturing process information. Resistance force data during machining were acquired using tool dynamometer known as sensor which is comparably accurate and reliable in operation. Tool status during the process was analyzed using influnece diagram assigning probability from the statistical analysis procedure.

  • PDF

Treatment of Gingival Irritation Fibroma Using $CO_2$ Laser (이산화탄소 레이저($CO_2$ laser)를 이용한 치은에 발생한 자극성 섬유종의 치료)

  • Choi, Young-Chan;Park, Ju-Hyun;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.2
    • /
    • pp.119-122
    • /
    • 2010
  • Carbondioxide($CO_2$) laser is one of the most widely employed lasers in oral soft tissue surgery because of its excellent affinity for water based soft tissues. It has some inherent advantages such as hemostasis, less postoperative swelling, reduction of bacterial population at surgical site, less need for suturing, less scarring, and less postoperative pain compared to conventional surgical therapies including the use of scalpel, diathermy, cryotherapy and electrosurgery. A 30-years-old male was presented with gingival swelling. Clinical examination revealed a well?defined pedunculated fibrotic mass on the buccal gingiva near right maxillary 1st molar. In radiographic examination, no remarkable abnormality was seen. Excisional biopsy was performed with $CO_2$ laser (continuous wave mode, 4.0W). Histological diagnosis was "Irritation fibroma". $CO_2$ laser has advantages those are suitable for surgical treatment of intraoral lesion. If appropriate training and experience are provided, the dentist would be able to manage intraoral lesions more efficiently and successfully with the use of the $CO_2$ laser.

Non-contact Stress Measurement in Steel Member of PSC Box Bridge Using Raman Spectroscopy (라만 형광 분광법을 이용한 PSC 박스교 인장케이블 응력측정방법 연구)

  • Kim, Jongwoo;Kim, Namgyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.130-134
    • /
    • 2019
  • In this paper, a laser-based non-contact load cell is newly developed for measuring forces in prestressed concrete tendons. First, alumina particles have been sprayed onto an empty load cell which has no strain gauges on it, and the layer has been used as a passive stress sensor. Then, the spectral shifts in fluorescence spectroscopy have been measured using a laser-based spectroscopic system under various force levels, and it has been found that the relation of applied force and spectral shift is linear in a lab-scale test. To validate the field applicability of the customized load cell, a full-scale prestressed concrete specimen has been constructed in a yard. During the field test, it was, however, found that the coating surface has irregular stress distribution. Therefore, the location of a probe has to be fixed onto the customized load cell for using the coating layer as a passive stress sensor. So, a prototype customized load cell has been manufactured, which consists of a probe mount on its casing. Then, by performing lab-scale uniaxial compression tests with the prototype load cell, a linear relation between compression stress and spectrum shift at a specific point where laser light had been illuminated has been detected. Thus, it has a high possibility to use the prototype load cell as a force sensor of prestressed concrete tendons.

Laser 방식 및 CCD 방식 Film Digitizer의 균일도 비교평가

  • 강원석;정해조;민덕기;김새롬;이상호;김희중
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.80-80
    • /
    • 2003
  • 디지털 의료영상 획득기술과 컴퓨터 및 네트워크 기술의 발달로 현재 각 병원에서는 PACS(Picture Archiving and Communication System)를 설치하여 필름을 사용하지 않고 진단과 진료를 하는 병원이 증가하고 있으며, 이에 따라 기존 필름상태의 의료영상은 필름디지타이저로 디지털 영상화한 후 모니터를 통하여 판독과 진료에 이용하고 있다. 본 연구에서는 현재 세브란스병원에서 사용되고 있는 CCD 방식 필름디지타이저와 레이저 스캐너방식 필름디지타이저의 픽셀값 균일도에 대해 중점적으로 비교, 분석하고자 한다. 픽셀값 균일도 측정을 위해 필름프린터를 이용하여 균일한 광학밀도를 가진 필름을 출력하였다. 그 테스트 필름은 각 사분면에 각기 다른 광학밀도를 가지고 있었으며, 그 광학밀도 값은 각각 0.19, 0.71, 1.41, 그리고 3.10 이었다. 제작된 필름은 레이저 (Model 2905, Array Corp., Japan) 방식과 CCD 방식 (SEDAS Media Film Scanner, Kodak, japan) 디지타이저에 의해 디지털화 되었다. 그 영상들은 다시 분석을 위해 PACS를 통해 PC로 전송되어졌고 자체 제작된 소프트웨어를 이용하여 균일도에 대한 분석을 수행하였다. 하나의 사분면 영상에 대하여 일정한 간격과 크기로 20개의 ROI를 만들고, 그 내부의 픽셀값들의 평균값을 구하여 그 영역의 대푯값으로 하였다. 그 대푯값들 중 최대값과 최소값의 차이에 대한 백분율로써 균일도를 표시하였다. 그 결과 광학밀도가 0.19인 사분변의 영상에서의 균일도는 레이저 방식 및 CCD 방식 각각에서 99.8%, 94.3%였으며, 0.71인 사분면에서는 99.4%, 75.6%, 1.41 일때는 97.9%, 62.96%, 그리고 3.1인 사분면에서는 82.7%, 53.7%였다. 같은 광학밀도를 가진 사분면에서는 레이저방식의 균일도가 CCD 방식에 비해 더 우수함을 알 수 있었으며, 같은 방식에서 얻은 영상이라 할지라도 광학 밀도값이 높은 사분변에서 얻은 영상일수록 균일도가 떨어짐을 알 수 있었다. 결론적으로, 레이저 방식 필름 디지타이저는 균일도 면에서도 CCD 방식에 비해 우수함을 알 수 있었으며 CCD 방식은 백라이트의 균일도가 영상의 균일도에 영향을 미칠수도 있는 만큼 향후 거기에 대한 연구도 이루어져야 할 것으로 생각된다.

  • PDF

Technology and Market Trend Analysis of the Laser Slide Marking System (레이저 슬라이드 마킹 시스템의 기술 및 시장동향 분석)

  • Kwon, young-il
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.457-461
    • /
    • 2007
  • Laser slide marking systems are being considered by the staffs of clinical laboratories in hospitals as the main potential substituent for the conventional manual processes of the laboratory works. Many of the processes in domestic hospitals such as operations of test equipments in clinical laboratories and physical distributions in hospitals are being computerized due to the recent development of information technologies. The clinical laboratories in charge of inspection processes are putting their efforts on the computerization and automation of the test equipments, which increases the demand for the usage of laser marking slide systems which is the main component of the inspection works. The domestic market size of the laser slide marking systems is expected to be 250 million won in 2008, which is believed to increase to 1.75 billion won in 2012. The laser slide marking system was first introduced to domestic hospitals in 2005. It's product life cycle is currently on the early stage, and it is believed to have a very high growth potential in the future.

  • PDF

연소진단 용 광대역 코헤런트 반 스톡스 라만 분광기의 제작 및 정확도 분석.

  • Park, Cheol-Ung;Park, Seung-Nam;Han, Jae-Won;Park, Bu-Min;Sin, Hyeon-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.33-44
    • /
    • 1997
  • 연소상태의 온도를 이동하면서 측정할 수 있는 광대역 코헤런트 반스톡스 라만 분광기를 제작하였다. 분광기의 온도 측정 정확도를 향상시키기 위하여 무모드레이저를 제작하여 스톡스광으로 사용하였다. 이동형 CARS 분광기에 적합하도록 CARS신호 측정용 단색기를 제작하여 분광기 내부에 설치 하였다. CARS 분광기의 온도 측정의 정확도를 알아보려고 흑연관 전기로를 이용하여 표준 복사온도계와 CARS 분광기로 측정한 온도의 차이를 측정하였다. 장치의 온도 정확도는 1000 K - 2400 K 사이의 온도영역에서 2%이내 였다. 무모드 색소레이저의 출력 스펙트럼의 시간에 따른 안정도를 측정하여 온도측정에 미치는 오차를 조사한 결과 1500 K에서 5 시간 동안 1.5 %이내 였다. 평면 화염 버너에서 프로판공기 예혼합 화염의 온도 분포를 측정하여 이 장치의 응용 가능성을 확인하였다.

  • PDF

Measurement of combustion gas temperature using laser-induced breakdown spectroscopy (레이저 유도 플라즈마 분광분석법을 이용한 연소 가스 온도 측정 기술)

  • Lee, Seok Hwan;Kim, Yong-Gyoo;Kang, Woong;Joung, Wukchul;Lee, Joo Hyun;Kim, Sunghun;Yang, Inyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.285-289
    • /
    • 2017
  • Laser-induced breakdown spesctroscopy (LIBS) is a technique that complements the disadvantages of conventional laser-based combustion diagnosis techniques such as weak signal strength, complex equipment configuration, and low accuracy. In this study, basic research was carried out to measure the combustion gas temperature of scramjet engines using LIBS. Spray flames were generated from Jet A-1 fuel used in scramjet engines and gas temperatures were measured at the top of the flames with a calibrated thermocouple. The LIBS signals were acquired at the same points as the temperature measurement positions of the thermocouple. The LIBS spectra were analyzed to obtained a calibration curve between the LIBS signal and the reference temperature measured at the thermocouple. Therefore, it was confirmed that the combustion gas temperature can be measured in-situ using LIBS.

  • PDF

Integration of 3D Laser Scanner and BIM Process for Visualization of Building Defective Condition (3D 레이저 스캐닝과 BIM 연동을 통한 건축물 노후 상태 정보 시각화 프로세스)

  • Choi, Moonyoung;Kim, Sangyong;Kim, Seungho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.2
    • /
    • pp.171-182
    • /
    • 2022
  • The regular assessment of a building is important to understand structural safety and latent risk in the early stages of building life cycle. However, methods of traditional assessment are subjective, atypical, labor-intensive, and time-consuming and as such the reliability of these results has been questioned. This study proposed a method to bring accurate results using a 3D laser scanner and integrate them in Building Information Modeling (BIM) to visualize defective condition. The specific process for this study was as follows: (1) semi-automated data acquisition using 3D laser scanner and python script, (2) scan-to-BIM process, (3) integrating and visualizing defective conditions data using dynamo. The method proposed in this study improved efficiency and productivity in a building assessment through omitting the additional process of measurement and documentation. The visualized 3D model allows building facility managers to make more effective decisions. Ultimately, this is expected to improve the efficiency of building maintenance works.

Fabrication of Compact Ruby Laser and its Operation Characteristics (플라즈마 진단용 소형 루비레이저의 제작과 동작특성에 관한 연구)

  • Jin, Yun-Sik;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1271-1274
    • /
    • 1995
  • In this paper, design feature and operation characteristics of compact Ruby laser for plasma diagonostics are described. A linear Xe flashlamp and a single elliptical cavity are adopted as optical pumping system. With charging energy of 484J, the maximum output energy of 170mJ, laser pulse width $110{\mu}s$, and slope efficiency 0.09% were obtained. If Q-switch system is added to this laser, we suppose this laser will be quite enough for diagonizing plasma.

  • PDF

Clinical effect of combined treatment by subgingival curettage and $CO_2$ laser application (치은연하 소파술과 $CO_2$ 레이저의 병용시의 임상적 효과)

  • Lee, Sang-Heon;Jin, Mi-Sung;Im, Se-Ung;Kim, Chang-Sung;Choi, Seong-Ho;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.243-253
    • /
    • 2004
  • 최근의 레이저 기술의 발전은 치의화영역에서 많은 가능성을 제시해 주고 있으며, 레이저를 이용한 외과적 치료의 기전과 안전성은 많은 분야에서 입증되어 있다. 근래에는 치주학적 분야에도 레이저를 적용하려는 노력이 계속되어 왔으며, 치석의 제거나 치근면의 세균제거 등에서 효과를 제시한 연구들이 있었다. 본 연구의 목적은 $CO_2$ 레이저를 통상적 치은연하소파술과 병용하였을때의 임상적 효과를 임상 지수의 측정을 통하여 평가하는 것이다. 만성 중둥도-고도의 치주염으로 진단된 12명의 환자가 본 임상연구에 포함되었다. 한 환자에서 각각 2부위의 사분악을 선택하여 임의로 2가지 치료군에 다음과 같이 나누어 포함시켰다: 1) 치은연하 소파술만을 적용한 사분악을 대조군 2) 치은연하 소파술과 0.8W의 에너지 수준을 갖는 $CO_2$ 레이저를 병용하여 적용한 사분악을 Laser 군으로 포함하였다. 치주낭 탐침 깊이, 임상 부착 수준, 치은 퇴축 및 탐침시 출혈풍의 임상지수를 치료전과 술후 각각 1, 3, 6개월 경과시에 측정하여 다음과 같은 결과를 얻었다. 치주낭 탐침 깊이, 임상 부착 수준, 치은 퇴축 및 탐침시 출혈 등의 모든 측정한 임상지수에서 치료전 ${\cdot}$ 후를 비교하였을 때 통계적으로 유의한 개선을 보였다. 그러나 실험군과 대조군간의 비교에서는 치주낭 탐침 깊이, 임상 부착 수준에서는 통계적으로 유의한 차이를 보이지 않았다. 탐침시 출혈은 술후 6개월시에 Laser군에서 대조군에 비하여 통계적으로 유의성있는 차이를 보이며 감소하였다(p<0.05). 결론적으로 $CO_2$ laser를 비외과적 치주 치료에 부가적으로 적용하였을 때 염증 감소에 기여할 가능성이 있을 것으로 사료된다.