• Title/Summary/Keyword: 램프전류

Search Result 144, Processing Time 0.026 seconds

A Non-Linear Characteristics Modeling of High Frequency FL Lamp by Experimental Values (실험식을 이용한 고주파 형광램프의 비선형특성 모델링)

  • 함중걸;백수현
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.51-55
    • /
    • 1997
  • The high frequency fluorescnet lighting systems are widely used because of their high luminous efficacy. However, the performance of the fluorescnet lamp at high frequency reveals significant changes depending upon operating frequency, lamp shape, lamp voltage and current while adapting either an electronic or an magnetic ballast. Therefore the matching between the fluorescent lamp and the ballast is the major concern in designing a lighting system. In this paper, high frequency characteristics of the FHF32W lamp is measured in a range of frequencies from 12kHz to 50kHz. And we presented a model of a fluorescnet lamp with non-linear impedance depending on the lamp current. Finally, after identifying the operating condition under negative imped¬ance behavior as lamp current changing, we proposed a method of choosing the optimal parameter of a high frequency fluorescnet lamp and the result is analyzed.

  • PDF

An Experiment and Analysis for Standardize Measurement on CCFL (냉음극 형광램프의 표준화 계측을 위한 실험과 분석)

  • Jin, Dong-Jun;Jeong, Jong-Mun;Jeong, Hee-Suk;Kim, Jin-Shon;Lee, Min-Kyu;Kim, Jung-Hyun;Koo, Je-Huan;Gwon, Gi-Cheong;Kang, June-Gill;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.331-340
    • /
    • 2008
  • A method of measuring the current and voltage is suggested in the circuit of cold cathode fluorescent lamps (CCFLs) which are driven at a high frequency of $50{\sim}100\;kHz$ and a high voltage of several kV. It is difficult to measure the current and voltage in the lamp circuit, because the impedance of the probe at high voltage side causes the leakage current and the variation of luminance. According to the analysis of equivalence circuit with the probe impedance and leakage current, the proper measuring method is to adjust the input DC voltage and to keep the specific luminance when the probe is installed at a high voltage circuit. The lamp current is detected with a current probe or a high frequency current meter at the ground side and the voltage is measured with a high voltage probe at the high voltage side of lamp. The lamp voltage($V_C$) is measured between the ballast capacitor and the lamp electrode, and the output voltage($V_I$) of inverter is measured between inverter output and ballast capacitor. As the phases of lamp voltage($V_C$) and current ($I_G$) are nearly the same values, the real power of lamp is the product of the lamp voltage($V_C$) by the lamp current($I_G$). The measured value of the phase difference between inverter output voltage($V_I$) and lamp current($I_G$) is appreciably deviated from the calculated value at $cos{\theta}=V_C/V_I$.

Acoustic-Resonance Reduction of Metal Halide Lamps Using Amplitude Modulation (진폭변조에 의한 메탈핼라이드 램프의 음향공명 감소)

  • 이치환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.43-49
    • /
    • 2000
  • In this paper, a new control method is presented to reduce acoustic resonance phenomena of metal halide lamps with electronic ballasts. A behavior of frequency controlled resonant inverter is analyzed and the transfer function is obtained. An integrator as a current controller for ballast is employed. By using both a disturbance of the lamp power and spread spectrum effects for reducing acoustic resonance, an amplitude modulation is done by using the current controller with 200[Hz] sinusoidal wave. Arc stabilities of MH 250[W] lamps are studied with changing the modulation index. Experiments with two MH 250[W] lamps, made by different manufacturers, showed the validity of the proposed method.

  • PDF

Discharge Characteristics of the Cold Cathode and External Electrode Fluorescent Lamps (냉음극 및 외부전극 형광램프의 방전 특성)

  • Cho Guangsup;Lee Dae H.;Lee Joo Y.;Song Hyuck S.;Gill Doh H.;Koo Je H.;Choi Eun H.;Kim Sang B.;Kim Bong S.;Kang June G.;Cho Mee R.;Hwang Myung G.;Kim Young Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.1
    • /
    • pp.49-57
    • /
    • 2005
  • The characteristics of current and voltage in a basic discharge experiment are investigated for a cold cathode fluorescent lamp with ballast capacitors attached at both ends of lamp and for a capacitive coupled external electrode fluorescent lamp. In the current-voltage characteristics for a cold cathode fluorescent lamp except ballast capacitors, it is shown that the typical glow discharge with the cathode fall follows after the dark current and Townsend firing discharge. However, in the characteristics for a cold cathode fluorescent lamp including ballast capacitors, the current increases as the voltage increases in the glow discharge region without representing a cathode fall since the most voltage is loaded at two capacitors. The characteristics for the external electrode fluorescent lamp shows the same as that of the cold cathode fluorescent lamp in the respect of glow discharge characters, and the external electrode itself roles the ballast capacitor.

A Theoretical Analysis of Voltage and Current in Low Pressure Mercury-Argon Mixture Gas Discharge with Frequency Variation (저압 수은-아르곤 혼합기체 방전의 주파수에 따른 전압, 전류 변화의 이론적 해석)

  • Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.23-27
    • /
    • 2005
  • A fluorescent lamp which uses low pressure mercury-argon gas discharge shows the maximum current and minimum lamp voltage near 1(kHz) source frequency at constant power. For explain these phenomena theoretically, in this paper a atomic level discharge model was made and particle density and electron temperature variation were calculated using numerical method.

LCD 백라이트용 형광램프에서의 광 방출 광의 전파

  • Im, Yu-Ri;Han, Guk-Hui;Jeong, Jong-Yun;Im, Hyeon-Gyo;Jo, Yun-Hui;Kim, Hyeon-Cheol;Yu, Dong-Geun;Jo, Gwang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.417-417
    • /
    • 2010
  • 작은 직경의 외부 전극 형광램프와 냉음극 형광램프는 LCD-TV의 광원으로 사용하고 있다. 교류 전압으로 구동되는 외부전극 형광램프와 교류 및 직류 전압으로 구동되는 냉음극 형광램프에서 광 방출 신호를 관측하였다. 이러한 빛은 양광주의 고전압부에서 접지부로 $10^5-10^6\;m/s$의 속도로 전파한다. 램프에서 방출된 광이 양광주를 따라 전파하는 현상은 일반 형광등과 네온싸인관에서도 동일하게 관측된다. 이러한 빛의 전파 현상은 지난 70년의 형광 램프 역사상 처음 관측되었다. 양광주 영역의 플라즈마는 높은 전압과 수 십 kHz가 인가되는 전극부에서 발생한 고밀도 플라즈마의 확산으로 생성된다. 고전압이 인가된 전극부에서 발생한 고밀도의 플라즈마는 인가되어지는 구동 주파수에 해당하는 섭동으로 작용하여 플라즈마 파동으로 양광주 영역으로 전파된다. 이러한 플라즈마 파동은 고밀도 전극부에서 저밀도 양광주 영역으로 플라즈마 밀도의 차이에 의하여 된다. 이때 파동의 전파 속도는 관 전류에 따라 달라진다. 타운젠트 방전 이전의 저 전류일 때는 ${\sim}10^5\;m/s$이며, 타운젠트 방전 이후 글로우 방전에서의 전파 속도는 ${\sim}10^6\;m/s$로 증가한다. 또한 타운젠트 방전 이전의 저 전류에서는 파동이 감쇠하는 경향을 보이며, 고 전류에서의 파동의 감쇠는 매우 작다. 관측된 광신호의 결과로부터 전파되는 파동의 원인은 플라즈마 확산에 의한 밀도의 차이에 의한 것으로 해석된다. 즉, 수 십 kHz의 구동 주파수를 갖는 플라즈마 파동이 양광주의 플라즈마 밀도 구배에 의하여 전파된다. 이러한 파동은 높은 전압이 인가되는 전극부에서 낮은 전압부로 향하는 조류의 흐름과 같이 나타난다.

  • PDF

Power supply design and discharge characteristics analysis of xenon flashlamp by using LLC resonance rhenomena (LLC 공진현상을 이용한 제논 플래쉬램프 전원회로의 설계 및 방전특성분석)

  • Lee, Hee-Chang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.312-317
    • /
    • 2014
  • In this paper, I propose the design technology of LLC resonant converter for the xenon flashlamp that is used to the solid state laser. Through the fabrication of 1.5kW large scale LLC resonant converter, the discharge characteristics are carried out, and introduce the new control method for limiting inrush current by the abrupt load current changes. The mathematical modeling for the lamp discharge includes the internal loss and lamp parameters. I propose the optimal method for the driving conditions of xenon flashlamp from the simulation results comparing the real measurements.

전해질 무첨가 전기/UV 공정을 이용한 염료의 제거

  • Park, Yeong-Sik;Kim, Dong-Seok
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.350-354
    • /
    • 2008
  • 전기/UV 공정에 사용하기 위해 일반적인 살균 램프인 UV-C 램프와 오존도 같이 발생하는 오존 등의 RhB 분해능을 고찰한 결과 오존 램프의 RhB 제거율이 UV-C램프보다 높은 것으로 나타났다. 전해질을 첨가하지 않은 전기/UV 공정에서 최적 전류는 1 A로 나타났다. 전기/UV 공정에서 RhB 제거의 경우 전기분해 공정과 UV 공정의 단일 공정의 RhB 농도감소와 전기/UV 복합 공정의 RhB 제거는 같아 공정의 시너지 효과는 관찰되지 않았다. 그러나 COD의 경우 전기분해 공정과 오존 램프에 의한 단일 공정의 COD 제거보다는 전기/UV 공정의 COD 제거농도가 높아 시너지 효과가 나타나는 것으로 사료되었다.

  • PDF

The Algorithm of Life Time Examination for High pressure Natrium Lamp (고압나트륨램프의 수명진단 알고리듬)

  • Han, Tae-Hwan;Woo, Chun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2323-2325
    • /
    • 2004
  • 고압방전등을 점등하기 위해서는 고전압의 시동전압이 필요하게 되는데, 이러한 시동전압은 고 압력의 나트륨램프에서도 필요하게 된다. 자기장은 전기 방전튜브에서 만들어지게 되며 증기 원자에 대한 전자충돌이 가속화되면서 2차 전자가 발생하고 전기 방전튜브에 전류가 급속도로 흐르게 되며, 나트륨램프의 제자회사마다 서로 다른 램프의 수명 및 교환시점도 서로 다르게 다는 것을 본 논문의 연구과정에서 발견하게 되었다. 본 논문에서는 LabVIEW 소프트웨어패키지를 사용해서 발견한 내용을 나트륨램프의 수명진단의 알고리즘을 제안한다.

  • PDF

A Characteristics Modelling of Start-up and Frequency of Fluorescent Lamp by Empirical Values (실험치에 의한 형광램프의 기동 및 주파수특성 모델링)

  • 함중걸;백수현;김일남;맹인재
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.21-25
    • /
    • 1996
  • 형광램프 시스템의 설계에서 안정기의 실패는 형광램프의 특성을 고려하는 것이 매우 중요하다. 특히, 시동시 과도특성에 근거한 형광램프의 동작모델을 등가회로로 알아내기 위해 실험에 의해 얻어진 결과를 등가희로 모델링과 Pspice 시뮬레이션에 의해 나타난 결과와 비교 분석하였으며, 특히 고주파용 형광램프의 동작 특성은 동작주파수, 형상, 램프 전압 및 전류값에 따라 차이가 많기 때문에 형광램프의 특성은 안정기의 특성을 고려한 형광램프 시스템에 동작특성 정합성에 매우 중요하다. 형광램프에 대한 고주파 특성으로 가장 많이 사용되는 주파수 영역(12Khz - 50Khz)에 대해서 실험, 분석한 결과 형광램프의 부(負)임피던스 동작특성을 파악하고 고주파 형광램프의 최적 특성치를 선택할 수 있는 방법을 제시하였다.

  • PDF