Properties of Harmful Substances Absorption Eco-friendly Artificial Stone Containing Basalt Waste Rock (현무암 폐석을 첨가한 유해물질 흡착 친환경 인조석재의 특성)

  • Pyeon, Su-Jeong;Gwon, Oh-Han;Kim, Tae-Hyun;Lee, Sang-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.431-438
    • /
    • 2016
  • Recently, Both rapid economic growth and high-quality native finishing materials demand in buildings such as local infrastructure facilities and cultural facilities have increased along with local quarries. So, increasing local quarries and environmental pollution occurred in quarries get the eyes to damaged area of the surroundings. As an example, carcinogen such as solid formed to fixing asbestos and dust have damaged to local resident. Especially, Radon gas released from asbestos can exist everywhere on earth, released soil and rock as radioactive substances, can be caused lung cancer followed by a smoking. When pollution source to indoor air quality that lacking ventilation rate of the residential building moved in a cycle, human responses such as headache, dizziness, etc. get appear, so on it threatened resident's physical condition. Thus, we need to urgent attention to reduction harmful substance. In the case of radon gas of the pollution source to indoor air quality in housing, it has characteristic that keep on going through half-life released from source, we need to control radon gas source than source removal. We set on vermiculite addition ratio to 10% which has harmful substances adsorption performance, proceed experiment to basalt waste rock addition ratio 50, 60, 70, 80(%). The result of an experiment, based on 'KS F 4035, precast terrazzo', we can be obtainable in the best terrazzo at basalt waste rock addition ratio 70%.

A Study on Drainage System of Non-motorized For Overtopping and Radon Reduction (무동력 배수시스템을 활용한 도상월류 및 라돈저감방안 연구)

  • Ko, Soung-Gee;Kuk, Yun-Mo;Kim, Man-Hwa;Park, Jong-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.208-213
    • /
    • 2011
  • Seoul Metropolitan Rapid Transit Corporation has 148's stations. Total length is 152km and most of the station is located in the basement and Groundwater occur inflow of 700,000 tons per day. Groundwater is treated as a natural flow way instead of artificial ways. Therefore, most of the collection wells is located in the low place or station for the efficient induction and collecting water. Manhole overtopping is occurring frequently because groundwater is concentrated in the drain pipe near the collecting well and heavy rainfall in summer. As a result, ballast contamination and radon levels are increased in tunnel. This paper introduces a solution is increasing overflow in tunnel, which introduces drainage system of non-motorized that uses differencial head between collecting well and manhole.

  • PDF

A Questionnaire Design Strategy for Enhancing the Rationality and Testing for the Validity of Choice Experiments Using Example Choice Questions (Choice Experiments의 합리성 제고 및 타당성 검증을 위한 설문지 디자인 연구 - 예제 도입 방안을 중심으로 -)

  • Kim, Yong-Joo
    • Environmental and Resource Economics Review
    • /
    • v.14 no.1
    • /
    • pp.1-24
    • /
    • 2005
  • One of the most important factors that determine the quality of a stated preference study is questionnaire design. This study introduces strategies for enhancing the rationality and testing for the validity of choice experiments(CE) using "example" choice questions that mimic the main choice questions. From the case study of WTP for reduced radon radiation exposures in the home, the study found that screening out irrational responses, 12% of the effective responses, resulted in a meaningful increase in model fit. Meanwhile the study tested for anchoring effects, as a way of confirming the divergent validity of the study, by looking at equality of models estimated for two subsamples. The overall test results were mixed. The pros and cons of the questionnaire design strategy employed are also reported.

  • PDF

Performance Test of the Ultralow Background Gamma-Ray Measurement System (극저준위 백그라운드 감마선 측정시스템의 성능시험)

  • Na, Won-Woo;Lee, Young-Gil
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.219-226
    • /
    • 1997
  • Ultralow background gamma-ray measurement system was installed to measure and analyze gamma-rays emitted from environmental and swipe samples. The background reduction techniques applied on this system are the passive shielding to surround the HPGe detector, an active external anticosmic shield to shield cosmic-rays and the nitrogen gas supply to minimize the introduction of ubiquitous radon decay nuclei. The performance test result showed that the system background at energies between 50 keV and 2 MeV is reduced about $10^{-2}$ order and the MDA is so low as to be suitable for the environmental sample analysis. But it is appeared that the neutron produced by cosmic-ray increases the background at low energy region.

  • PDF

Concentration Distributions and A Reduction Strategy of Airborne Radon in Seoul Metropolitan Subway Stations (서울시 지하철역내의 라돈 농도분포 및 저감대책)

  • 김동술;김윤신;김신도;신응배;김성천;유정석
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.4
    • /
    • pp.271-277
    • /
    • 1993
  • Indoor radon has been known as one of the notorious carcinogens. However, a safe environmental criterion of radon has not yet been established in Korea, The main objectives of this study were to study concentration distributions of radon, to trace radon sources in subways, and to obtain a strategy for radon reduction in Seoul metropolitan area. Radon concentrations had been extensively determined by several steps. The first step was to survey radon levels in all of 83 subway stations from October to November in 1991. The second step was to select 40 out of 83 stations and then to study seasonal variations in 1991 and 1992. The third step was to monitor radon levels by hourly-basis plans. The fourth step was to seek a radon reduction strategy by altering ventilation at Ankuk station where had the highest radon concentration during the first measurement step. Each underground floor in the station was divided into 10 sites to measure hourly radon variations. The final step of the study was to measure radon concentrations in groundwater that is one of the possible main sources radon place. The result of the various measuring approaches showed short-and long-term radon variation and indicated radon reduction schemes.

  • PDF

Natural Reduction Characteristics of Radon in Drinking Groundwater (음용 지하수 중 라돈 자연저감 특성)

  • Noh, Hoe-Jung;Jeong, Do-Hwan;Yoon, Jeong-Ki;Kim, Moon-Su;Ju, Byoung-Kyu;Jeon, Sang-Ho;Kim, Tae-Seung
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.1
    • /
    • pp.12-18
    • /
    • 2011
  • To investigate the natural reduction characteristics of radon with a short half-life (3.82 day) in drinking Qgroundwater, we analyzed the changes of radon concentrations of groundwater, waters in storage tanks, and tap waters from the small-scale groundwater-supply systems (N = 301) by LSC (Liquid Scintillation Counter). We also analyzed the concentrations of uranium (half-life 4.5 billion years) in the waters by ICP/MS to compare with natural reduction of radon concentration. The radon concentrations of 68 groundwater-supply systems occupying 22.6% of the total samples exceeded the US EPA's Alternative Maximum Contaminant Level (AMCL : 4,000 pCi/L), with the average radon concentration of 7,316 pCi/L (groundwaters), 3,833 pCi/L (tank waters) and 3,407 pCi/L (tap waters). Compared to the radon levels of pumped groundwaters, those of tank and tap waters naturally reduced significantly down to about 50%. Especially, in case of 29 groundwater-supply systems with the groundwater radon concentrations of 4,000~6,000 pCi/L, average radon concentrations of the tank and tap waters naturally decreased down to the AMCL. Therefore this study implies that radon concentrations of drinking groundwater can be effectively reduced by sufficient storage and residence in tanks.

Cost-benefit Analysis on Occupational Reference Levels for Radon (지각방사선(라돈) 참조준위별 저감 대책에 따른 비용 편익 분석)

  • Choi, Eun-Hi;Chung, Eun Kyo;Kim, Su-Geun;Jung, Myung-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.1
    • /
    • pp.57-68
    • /
    • 2019
  • Objective: The purpose of this study is to propose the benefits of reduction measures according to the occupational radon reference level in order to present basic data for radon management guidelines considering domestic circumstances. Methods: This study uses radon data measured in the subway stations from 2015 to 2016. Of the total of 4,643 cases, 4,231 cases were analyzed excluding the 412 cases where the values were below $300Bq/m^3$. Results: Cost-Benefit analysis was done on the results of the field survey on subway work sites. At the exposure level of $400Bq/m^3$, the ratio between the cost and the benefit was highest at 1 : 1.81(the cost was KRW 1,398,568,032, while the benefit KRW 2,5248,772,841). At the exposure level of $600Bq/m^3$, the ratio of cost and benefit was 1: 1.80, at $300Bq/m^3$ it was 1.72, at $800Bq/m^3$ it was 1.71, at $200Bq/m^3$ it was 1.54, and at $100Bq/m^3$ it was 1.40. Conclusions: Radon management in the workplace provides economic benefits and appropriate reduction strategies are needed. In addition, it is necessary to establish and distribute radon exposure assessment procedures and guidelines for the safety and health of employees when exceeding the exposure standard, and guidelines for radon management in the workplace should be established.

Evaluation for Effectiveness of Radon Mitigation on Dwellings and Public Buildings in Korea (건축물 유형에 따른 라돈 저감 효과 평가)

  • Lee, DongHyun;Ryu, Seung-Hun;Jo, JungHeum;Seo, SungChul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.518-527
    • /
    • 2014
  • Objectives: The adverse health effects attributed to exposure to radon have been well known over the world. However, the efforts for prevention and mitigation of radon have not been taken in Korea so far. The purpose of this study was to evaluate the effectiveness of mitigation methods applied for various types of houses and public buildings with high level of radon. Methods: Based on the results of "National Radon Survey" performed by the National Institute of Environmental Research(NIER) in 2010-2012, we selected 30 candidate buildings consisting of 20 houses and 10 public buildings with greater than $148Bq/m^3$ of radon level. We measured the concentration of radon in 30 buildings, using E-PERMs and RAD-7 during January to March of 2013. More than five E-PERMs and one RAD-7 per house were installed for seven days. Ten houses and five public buildings were finally chosen to be mitigated after mainly considering the level of radon and the location of buildings nationwide. Three mitigation methods such as Sealing, two types of Active Ventilation(window-shaped and wall-typed ventilations), and Active Soil Depressurization(ASD) were applied, and the concentrations of radon were measured before and after mitigation, respectively. To evaluate the effectiveness of mitigation methods, reduction rates of radon were calculated and Wilcoxon's signed-rank test was performed. Results: The mean concentration of 15 buildings just before radon mitigation was $297.8Bq/m^3$, and most of the buildings were located in Gangwon, Chungbuk, Chungnam, and Daegu areas(73.3%), and built in 1959-1998. The level of radon decreased from 48% to 90% and kept the below recommendation limit of $148Bq/m^3$ after installation of radon mitigation. Among mitigation methods applied, the reduction rate(58.7-90.4%) of radon attributed to ASD was the greatest than that of other methods, followed by Active Ventilation(48.4-78.4%) and Sealing(<22%). The effectiveness of radon reduction by window-shaped Active Ventilation(63.2-75.2%) was relatively better than that of wall-typed Active Ventilation(48.4-54.3%). Conclusions: The results of this study indicate that ASD could be more effective for radon mitigation. Moreover, our findings would be background information in future for making the strategy for radon mitigation nationwide, as well as for developing Korean-version of mitigation techniques according to types of dwellings in Korea.