• Title/Summary/Keyword: 디퓨저(diffuser)

Search Result 177, Processing Time 0.028 seconds

Analysis of Homogenized Laser Beam Display by a Polymeric Stretchable Diffuser (스트레쳐블 폴리머 디퓨저를 이용한 균질 레이저 디스플레이 해석)

  • Lee, Jae-Won;Lee, Seon-Bong;Choi, Hae-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • A stretchable polymeric membrane shaped diffuser was used to homogenize the coherent laser beam. The developed RGB module was used to focus and defocus test by beam combiners. Average oscillation frequency was set at 180Hz~300Hz and it resulted in the best homogenization effect in visual range. The blue laser module turned out to be the worst case for the transmission and primary reason is believed to be the short length of irradiated laser beam. The developed system removed the speckling and the brightness was decreased by 10 ~ 20% for the RGB laser. Overall the brightness was decreased by 13% and homogenity with respect to the temporal axis was improved from 30fs to 110fs.

Flow Visualization and Calculation at the Outlet of Propellant Tank Pressurizing Gas Injector (추진제탱크 가압용 인젝터 출구에서의 유동가시화 및 해석)

  • Kwon, Oh-Sung;Han, Sang-Yeop;Kwon, Ki-Jung;Chung, Yong-Cahp
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.73-79
    • /
    • 2010
  • Propellant tank pressurizing gas injector is used in the pressurization system of liquid propellant rocket to reduce incoming gas velocity and distribute the gas in the tank. Temperature distribution in the propellant tank ullage is varied according to the gas injector shape, and it has influence on the required pressurant gas and thermal phenomena in the tank. In this paper, diffuser type gas injector was studied to make the ullage have stratified temperature distribution. Injected gas flow at the outlet of prototype diffuser was visulized using particle image velocimetry method and it was compared with the results of calculation. Calculation was well agreed with measurement and was used as an inlet condition of propellant tank ullage calculation.

Numerical Analysis on Flow Uniformity According to Area Ratio and Diffuser Angle in an SCR Reactor of a 500 PS-Class Ship (500 PS급 선박 SCR 반응기에서 디퓨저 각도와 면적비에 따른 유동균일도 수치해석)

  • Seong, Hongseok;Park, Inseong;Jang, Hyun;Park, Changdae;Kim, Hyunkyu;Jung, Kyoungyul;Suh, Jeongse
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.4
    • /
    • pp.394-399
    • /
    • 2015
  • Because flow uniformity affects the life cycle and performance of the catalyst, it is an important design factor for selective catalytic reduction (SCR) systems. We examined how the diffuser angle and the area ratio of the inlet of the SCR reactor to the front of the catalyst affect flow uniformity. For the numerical analysis, we used STAR-CCM+, a common CFD software program. Analysis results showed that the larger the area ratio was, the less the flow uniformity was, and that the longer the diffuser length was, the greater the flow uniformity was. When the area ratio was greater than 1:5, the flow uniformity appeared very similar at the front of the catalyst. As a result, the spread time of the exhaust gas increased and the flow velocity decreased.

The Secondary Chamber Pressure Characteristics of Sonic/Supersonic Ejector-Diffuser System (음속/초음속 이젝터 시스템의 2차정체실 압력특성)

  • 이준희;최보규;김희동;박종호
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.50-56
    • /
    • 2001
  • The present study is an experimental work of the soni $c^ersonic air ejector-diffuser system. The pressure-time dependence in the secondary chamber of this ejector system is measured to investigate the steady operation of the ejector system. Six different primary nozzles of two sonic nozzles, two supersonic nozzles, petal nozzle, and lobed nozzle are employed to drive the ejector system at the conditions of different operating pressure ratios. Static pressures on the ejector-diffuser walls are to analyze the complicated flows occurring inside the system. The volume of the secondary chamber is changed to investigate the effect on the steady operation. the results obtained show that the volume of the secondary chamber does not affect the steady operation of the ejector-diffuser system but the time-dependent pressure in the secondary chamber is a strong function of the volume of the secondary chamber.er.

  • PDF

Study on Design of Secondary Throat Supersonic Exhaust Diffusers (2차목 초음속 디퓨저 설계에 관한 연구)

  • Park, Jin-Ho;Lee, Yang-Suk;Kim, Joong-Il;Ko, Young-Sung;Kim, Sun-Jin;Kim, Yoo;Kim, Seung-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.881-884
    • /
    • 2011
  • Secondary throat supersonic exhaust diffusers were designed by Normal-shock theory and manufactured. Experimental studies of the diffusers were performed using nitrogen gas of room temperature. It showed a difference about 18% between the experimental and theoretical results. The difference was shown by friction loss at the wall of the diffuers.

  • PDF

Effects of Rear Diffuser Size on the Driving Performance of a Passenger Car (자동차의 주행 성능에 미치는 리어 디퓨저 크기의 영향)

  • Lee, Gyo Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.655-661
    • /
    • 2019
  • This study examined the change in driving performance according to the starting position of the rear diffuser of a vehicle. To accomplish this, the CATIA 3D design program was used to model the vehicle with reference to a commercial SUV vehicle and design the rear diffuser to start from 300, 400, and 500 mm from the rear tire. The flow and drag change were analyzed and the change in air flow was confirmed using Fluent, a flow analysis program at a vehicle traveling speed of 60, 100, and 140 km/h. The rear diffuser reduced the lift and drag forces compared to no diffuser regardless of the starting position. This is because if there is a rear diffuser, it will reduce the vortex phenomenon by suppressing the flow separation that occurs when air is drawn out from the rear portion of the vehicle. In this study, the starting point SP 400 was determined to be the optimal condition because the lift force was the smallest at SP 400 and the lift reduction effect was the best.

Numerical Analysis of Flow Rate Distribution of Diffusers with Various Shapes (다양한 디퓨저 형상의 유량 분배 특성에 관한 수치해석 연구)

  • Kim, Myoung Soo;Kim, Hoo Bae;Choi, Hyoung Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.789-795
    • /
    • 2014
  • In this study, the distribution characteristics of diffusers with various shapes that are installed in an open-type thermal storage system are numerically investigated. Four diffusers are designed to distribute a working fluid evenly through the holes on bifurcated pipes. Three-dimensional steady simulations of incompressible laminar flow are conducted using commercial software (ANSYS-FLUENT). The simulation results show that both the bidirectional header-type diffuser and the H-type diffuser distribute the working fluid evenly whereas both the unidirectional and the bidirectional diffusers distribute the working fluid unevenly. The results also show that the H-type diffuser requires a higher head of pump than the bidirectional header-type diffuser. Therefore, the bidirectional header-type diffuser is recommended for use because it enables even distribution of the working fluid and requires a low head of pump.

Design and Performance Test of 1300RT Centrifugal Compressor for a HFC-134a Turbo-Chiller (HFC-134a용 1300RT급 원심압축기의 설계 및 성능시험)

  • Ko, Kyung-Tae;Choi, Young-Min;Shin, Jeong-Kwan;Kim, Kyung-Hun
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.672-677
    • /
    • 2001
  • This study has been conducted to design the high efficiency centrifugal compressor for a HFC-134a. The 2-stage centrifugal compressor consists of inlet guide vanes, two impellers with splitters, a deswirler, a vaneless diffuser and a volute casing. We have designed the high efficiency centrifugal compressor by applying the repeated design procedure including a meanline design, a 3D geometry generation of 1st and 2nd impellers etc. Also, a fluid dynamic calculation of impellers and deswirler have been conducting using a commercial code STAR-CD.

  • PDF

The Design and Performance Test of a Centrifugal Compressor for HFC-134a (대체냉매용 원심압축기의 설계 및 성능시험)

  • Sin, Jung-Kwan;Kim, Kyung-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.250-257
    • /
    • 2002
  • A centrifugal compressor for HFC-l34a has been newly designed and developed. Flow analysis using commertial programs was used to evaluate performance and internal flow of the impeller, inlet guide vane and diffuser etc. and design software was developed. The compressor for HFC-l34a was also investigated experimentally to check compression performance. The calculated data coincide the test results of compressor. The data obtained in the present study are useful for design of HFC-l34a centrifugal compressors.

  • PDF

An Experimental Study on the Performance Evaluation of a Small-Sized Centrifugal Compressor (소형 원심압축기의 성능평가에 대한 실험적 연구)

  • Cho, Sung-Kook;Kang, Shin-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1052-1063
    • /
    • 1998
  • The performance database of small-sized centrifugal compressors is needed for the design of high performance machines and also for the verification of design tools and analysis software. An impeller is designed, manufactured and tested. The effects of several parameters on the evaluation of performance are investigated and the performance test of parallel diffuser is also carried out. The proper estimation of static pressure, total temperature and blockage at the impeller exit is important for performance evaluation. 4 method in cooperation with 3-D calculation is suggested. The measured performances are in a good agreement with the predicted results. However, there are some discrepancies in efficiency.