• Title/Summary/Keyword: 디지털 위치

Search Result 1,400, Processing Time 0.025 seconds

The evaluation of lens absorbed dose according to the Optimold for whole brain radiation therapy (전뇌 방사선치료 시 Optimold에 따른 수정체의 흡수선량 평가)

  • Yang, Yong Mo;Park, Byoung Suk;Ahn, Jong Ho;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 2014
  • Purpose : In the current whole brain Radiation Therapy, Optimold was used to immobilize the head. However, skin dose was increased about 22% due to the scattering radiation by the Optimold. Since the minimum dose causing cataracts was 2 Gy, it could be seen that the effects were large especially on the lens. Therefore, in the whole brain Radiation Therapy, it was to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part. Materials and Methods : In order to compare and to evaluate the lens absorbed dose according to the presence of Optimold in the eyeball part, the Optimold mask was made ??up to 5mm bolus on the part of the eye lens in the human model phantom (Anderson Rando Phantom, USA). In the practice treatment, to measure the lens dose, the simulation therapy was processed by placing the GafChromic EBT3 film under bolus, and after the treatment plan was set up through the treatment planning system (Pinnacle, PHILIPS, USA), the treatments were measured repeatedly three times in the same way. After removing the Optimold mask in the eyeball part, it was measured in the same way as above. After scanning the film and measuring the dose by using the Digital Flatbed Scanner (Expression 10000XL, EPSON, USA), the doses were compared and evaluated according to the presence of Optimold mask in the eyeball part. Results : When there was the Optimold mask in the eyeball part, it was measured at $10.2cGy{\pm}1.5$ in the simulation therapy, and at $24.8cGy{\pm}2.7$ in the treatment, and when the Optimold mask was removed in the eye part, it was measured at $12.9cGy{\pm}2.2$ in the simulation therapy, and at $17.6cGy{\pm}1.5$ in the treatment. Conclusion : In case of removing the Optimold mask in the eyeball part, the dose was increased approximately 3 cGy in the simulation therapy and was reduced approximately 7 cGy in the treatment in comparison to the case that the Optimold mask was not removed. During the whole treatment, since the lens absorbed dose was reduced about 27%, the chance to cause cataracts and side effects was considered to be reduced due to decrease of the absorbed dose to the eye lens which had the high sensitivity on the radiation.

Analyzing animation techniques used in webtoons and their potential issues (웹툰 연출의 애니메이션 기법활용과 문제점 분석)

  • Kim, Yu-mi
    • Cartoon and Animation Studies
    • /
    • s.46
    • /
    • pp.85-106
    • /
    • 2017
  • With the media's shift into the digital era in the 2000s, comic book publishers attempted a transition into the new medium by establishing a distribution structure using internet networks. But that effort shied from escaping the parallel-page reading structure of traditional comics. On the other hand, webtoons are showing divers changes by redesigning the structure of traditional sequential art media; they tend to separate and allot spaces according to the vertical scroll reading method of the internet browser and include animations, sound effects and background music. This trend is also in accordance with the preferences of modern readers. Modern society has complicated social structures with the development of various media; the public is therefore exposed to different stimuli and shows characteristics of differentiated perceptions. In other words, webtoons display more relevant and entertaining characteristics by inserting sounds and using moving texts and characters in specific frames, while traditional comics require an appreciation of withdrawal and immersion like other published media. Motions in webtoons are partially applied for dramatic tension or to create an effective expression of action. For example, hand-drawn animation is adopted to express motions by dividing motion images into many layers. Sounds are also utilized, such as background music with episode-related lyrics, melodies, ambient sounds and motion-related sound effects. In addition, webtoons provide readers with new amusement by giving tactile stimuli via the vibration of a smart phone. As stated above, the vertical direction, time-based nature of animation motions and tactile stimuli used in webtoons are differentiated from published comics. However, webtoons' utilization of innovative techniques hasn't yet reached its full potential. In addition to the fact that the software used for webtoon effects is operationally complex, this is a transitional phenomenon since there is still a lack of technical understanding of animation and sound application amongst the general public. For example, a sound might be programmed to play when a specific frame scrolls into view on the monitor, but the frame may be scrolled faster or slower than the author intended; in this case, sound can end before or after a reader sees the whole image. The motion of each frame is also programmed to start in a similar fashion. Therefore, a reader's scroll speed is related to the motion's speed. For this reason, motions might miss the intended timing and be unnatural because they are played out of context. Also, finished sound effects can disturb the concentration of readers. These problems come from a shortage of continuity; to solve these, naturally activated consecutive sounds or animations, like the simple rotation of joints when a character moves, is required.

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

An Oceanic Current Map of the East Sea for Science Textbooks Based on Scientific Knowledge Acquired from Oceanic Measurements (해양관측을 통해 획득된 과학적 지식에 기반한 과학교과서 동해 해류도)

  • Park, Kyung-Ae;Park, Ji-Eun;Choi, Byoung-Ju;Byun, Do-Seong;Lee, Eun-Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.4
    • /
    • pp.234-265
    • /
    • 2013
  • Oceanic current maps in the secondary school science and earth science textbooks have played an important role in piquing students's inquisitiveness and interests in the ocean. Such maps can provide students with important opportunities to learn about oceanic currents relevant to abrupt climate change and global energy balance issues. Nevertheless, serious and diverse errors in these secondary school oceanic current maps have been discovered upon comparison with up-to-date scientific knowledge concerning oceanic currents. This study presents the fundamental methods and strategies for constructing such maps error-free, through the unification of the diverse current maps currently in the textbooks. In order to do so, we analyzed the maps found in 27 different textbooks and compared them with other up-to-date maps found in scientific journals, and developed a mapping technique for extracting digitalized quantitative information on warm and cold currents in the East Sea. We devised analysis items for the current visualization in relation to the branching features of the Tsushima Warm Current (TWC) in the Korea Strait. These analysis items include: its nearshore and offshore branches, the northern limit and distance from the coast of the East Korea Warm Current, outflow features of the TWC near the Tsugaru and Soya Straits and their returning currents, and flow patterns of the Liman Cold Current and the North Korea Cold Current. The first draft of the current map was constructed based upon the scientific knowledge and input of oceanographers based on oceanic in-situ measurements, and was corrected with the help of a questionnaire survey to the members of an oceanographic society. In addition, diverse comments have been collected from a special session of the 2013 spring meeting of the Korean Oceanographic Society to assist in the construction of an accurate current map of the East Sea which has been corrected repeatedly through in-depth discussions with oceanographers. Finally, we have obtained constructive comments and evaluations of the interim version of the current map from several well-known ocean current experts and incorporated their input to complete the map's final version. To avoid errors in the production of oceanic current maps in future textbooks, we provide the geolocation information (latitude and longitude) of the currents by digitalizing the map. This study is expected to be the first step towards the completion of an oceanographic current map suitable for secondary school textbooks, and to encourage oceanographers to take more interest in oceanic education.

Development of Greenhouse Cooling and Heating Load Calculation Program Based on Mobile (모바일 기반 온실 냉난방 부하 산정 프로그램 개발)

  • Moon, Jong Pil;Bang, Ji Woong;Hwang, Jeongsu;Jang, Jae Kyung;Yun, Sung Wook
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.419-428
    • /
    • 2021
  • In order to develope a mobile-based greenhouse energy calculation program, firstly, the overall thermal transmittance of 10 types of major covers and 16 types of insulation materials were measured. In addition, to estimate the overall thermal transmittance when the cover and insulation materials were installed in double or triple layers, 24 combinations of double installations and 59 combinations of triple installations were measured using the hotbox. Also, the overall thermal transmittance value for a single material and the thermal resistance value were used to calculate the overall thermal transmittance value at the time of multi-layer installation of covering and insulating materials, and the linear regression equation was derived to correct the error with the measured values. As a result of developing the model for estimating thermal transmittance when installing multiple layers of coverings and insulating materials based on the value of overall thermal transmittance of a single-material, the model evaluation index was 0.90 (good when it is 0.5 or more), indicating that the estimated value was very close to the actual value. In addition, as a result of the on-site test, it was evaluated that the estimated heat saving rate was smaller than the actual value with a relative error of 2%. Based on these results, a mobile-based greenhouse energy calculation program was developed that was implemented as an HTML5 standard web-based mobile web application and was designed to work with various mobile device and PC browsers with N-Screen support. It had functions to provides the overall thermal transmittance(heating load coefficient) for each combination of greenhouse coverings and thermal insulation materials and to evaluate the energy consumption during a specific period of the target greenhouse. It was estimated that an energy-saving greenhouse design would be possible with the optimal selection of coverings and insulation materials according to the region and shape of the greenhouse.

K-DEV: A Borehole Deviation Logging Probe Applicable to Steel-cased Holes (철재 케이싱이 설치된 시추공에서도 적용가능한 공곡검층기 K-DEV)

  • Yoonho, Song;Yeonguk, Jo;Seungdo, Kim;Tae Jong, Lee;Myungsun, Kim;In-Hwa, Park;Heuisoon, Lee
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • We designed a borehole deviation survey tool applicable for steel-cased holes, K-DEV, and developed a prototype for a depth of 500 m aiming to development of own equipment required to secure deep subsurface characterization technologies. K-DEV is equipped with sensors that provide digital output with verified high performance; moreover, it is also compatible with logging winch systems used in Korea. The K-DEV prototype has a nonmagnetic stainless steel housing with an outer diameter of 48.3 mm, which has been tested in the laboratory for water resistance up to 20 MPa and for durability by running into a 1-km deep borehole. We confirmed the operational stability and data repeatability of the prototype by constantly logging up and down to the depth of 600 m. A high-precision micro-electro-mechanical system (MEMS) gyroscope was used for the K-DEV prototype as the gyro sensor, which is crucial for azimuth determination in cased holes. Additionally, we devised an accurate trajectory survey algorithm by employing Unscented Kalman filtering and data fusion for optimization. The borehole test with K-DEV and a commercial logging tool produced sufficiently similar results. Furthermore, the issue of error accumulation due to drift over time of the MEMS gyro was successfully overcome by compensating with stationary measurements for the same attitude at the wellhead before and after logging, as demonstrated by the nearly identical result to the open hole. We believe that the methodology of K-DEV development and operational stability, as well as the data reliability of the prototype, were confirmed through these test applications.

Radiation Dose Reduction in Digital Mammography by Deep-Learning Algorithm Image Reconstruction: A Preliminary Study (딥러닝 알고리즘을 이용한 저선량 디지털 유방 촬영 영상의 복원: 예비 연구)

  • Su Min Ha;Hak Hee Kim;Eunhee Kang;Bo Kyoung Seo;Nami Choi;Tae Hee Kim;You Jin Ku;Jong Chul Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.344-359
    • /
    • 2022
  • Purpose To develop a denoising convolutional neural network-based image processing technique and investigate its efficacy in diagnosing breast cancer using low-dose mammography imaging. Materials and Methods A total of 6 breast radiologists were included in this prospective study. All radiologists independently evaluated low-dose images for lesion detection and rated them for diagnostic quality using a qualitative scale. After application of the denoising network, the same radiologists evaluated lesion detectability and image quality. For clinical application, a consensus on lesion type and localization on preoperative mammographic examinations of breast cancer patients was reached after discussion. Thereafter, coded low-dose, reconstructed full-dose, and full-dose images were presented and assessed in a random order. Results Lesions on 40% reconstructed full-dose images were better perceived when compared with low-dose images of mastectomy specimens as a reference. In clinical application, as compared to 40% reconstructed images, higher values were given on full-dose images for resolution (p < 0.001); diagnostic quality for calcifications (p < 0.001); and for masses, asymmetry, or architectural distortion (p = 0.037). The 40% reconstructed images showed comparable values to 100% full-dose images for overall quality (p = 0.547), lesion visibility (p = 0.120), and contrast (p = 0.083), without significant differences. Conclusion Effective denoising and image reconstruction processing techniques can enable breast cancer diagnosis with substantial radiation dose reduction.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Analysis of Fruit Quality and Productivity of 'Kawanakajima Hakuto' Peach according to the Different Irrigation Starting Point (관수 개시점에 따른 복숭아 '천중도백도'의 과실 품질 및 생산성 변화 분석)

  • Seul Ki Lee;Jung Gun Cho;Jae Hoon Jeong;Dongyong Lee;Jeom Hwa Han;Si Hyeong Jang;Suhyun Ryu;Heetae Kim;Sang-Hyeon Kang
    • Journal of Bio-Environment Control
    • /
    • v.32 no.4
    • /
    • pp.475-483
    • /
    • 2023
  • This study was conducted to determine the optimal irrigation starting point by analyzing tree growth, physiological responses, fruit quality, and productivity in peach orchards. Seven-year-old 'Kawanakajima Hakuto' peach trees were used in an experimental field (35°49'30.4"N, 127°01'33.2"E) located within the National Institute of Horticultural and Herbal Science located in Wanju-gun, Jeollabuk-do. The irrigation starting point was set with four levels of -20, -40, -60, and -80 kPa from June to September 2022. While there were no significant differences in increase of trunk cross-section area and leaf area among treatments, shoot length and diameter decreased in the -80 kPa and -20 kPa treatments. The photosynthetic rate measured in August was highest for -60 kPa (17.7 μmol·m-2·s-1), followed by -40 kPa (15.6 μmol·m-2·s-1), -20 kPa (14.5 μmol·m-2·s-1) and -80 kPa (14.0 μmol·m-2·s-1). SPAD value measured in May and August was lower in the -80 kPa and -20 kPa treatments than in the -60 kPa and -40 kPa treatments. The harvest date reached three days earlier in the -20 kPa treatment compared to other treatments. The fruit weight was highest in the -60 kPa (379.1 g), followed by -40 kPa (344.0 g), -80 kPa (321.0 g) and -20 kPa (274.9 g). Firmness was the lowest in the -20 kPa treatment. The soluble solid content was highest in the -60 kPa treatment (13.3°Bx).The ratio of marketable fruits was highest in the -60 kPa treatment (50.7%) and lowest in the -80 kPa treatment (23.4%). In conclusion, we suggest that setting the irrigation starting point at -60 kPa could improve the fruit quality and yield in peach orchards.

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.