Image Enhancement and Clinical Evaluation in Digital Chest Radiography (디지털 방사선 흉부영상의 영상개선과 임상평가)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.143-149
    • /
    • 2008
  • The aim of this study is to suggest the method for image enhancement of digital chest radiograph and evaluate clinically the quality of the resultant image. A nonlinear iterative filter was developed in order to reduce quantum noise preserving edge. Dynamic range was adjusted and adaptive image enhancement was performed based on the property of anatomic region and the degree of compatibility with neighboring pixels. The lung fields were enhanced appropriately to visualize effectively vascular tissue, bronchus and lung tissue with the desired mediastinum enhancement. Clinic evaluation was performed by three radiologists with at least 8 years experience. The anatomic regions of 11 in PA and 9 in Lateral were observed carefully in each 100 radiographs according to ITU (International Telecommunication Union) recommendation 500 protocol. The result showed the mean 3.4 between good and adequate. This means that the clinical utility of the image quality is enough. In this study, image enhancement was carried out considering image display device and human perceptual system to prevent the loss of useful anatomic information. In order to increase the diagnostic accuracy in digital radiograph, the continuous study on image enhancement is needed.

  • PDF

Image quality assessment with dose reduction using high kVp and additional filtration for abdominal digital radiography (디지털 복부방사선검사에서 고관전압과 부가여과판을 사용한 선량감소와 영상평가)

  • Jang, ji-sung;Lee, ho-beom;Choi, kwan-woo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.59-60
    • /
    • 2018
  • 디지털 복부 방사선검사에서 고관전압과 부가필터를 이용한 선량감소가 최근 큰 관심을 받고 있다. 본 연구에서는 복부 방사선 검사에서, 기존 방법(80 kVp without filter)과는 다른 고관전압(92 kVp)과 부가필터(0.1 mm Cu-filter)를 사용하여 적절한 진단학적 영상품질을 유지하면서 상당한 환자 선량을 감소 시켰다. 따라서, 본 연구에 방법을 적절하게 이용하면 진단학적 영상품질을 유지하며 환자선량도 감소하는데 유용하리라 사료된다.

  • PDF

A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo (디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 -)

  • Jo, Gwang-Ho;Kang, Yeong-Han;Kim, Bu-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2008
  • Digital imaging for general rediography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  • PDF

Implementation of Digital Mammogram CAD Algorithm (디지털 유방영상의 CAD 알고리즘 구현)

  • Lee, Byungchea;Choi, Guirack;Jung, Jaeeun;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • Medical imaging has increased rapidly in the increase of interest in health, with the development of computer technology, digitization of medical imaging is rapidly advancing, PACS has been introduced to the medical field. Increase in the production of medical images by these phenomena made increased the workload of radiologist who must read a medical image. in response to the need for secondary diagnosis using a computer, The term of CAD in medical radiology field was introduced. In this study, we have proposed a CAD algorithm for the interpretation of the image obtained by the digital X-ray mammography equipment. The experiments were performed by programmed in Visual C++ for the proposed algorithm. A result of the execution of the CAD algorithm seven sample images, the results of five samples was confirmed in breast cancer and benign tumors, both the images sample was error processing. If you use a program that implements this with the algorithm proposed in this study it is helpful to reading breast images, and it is considered to contribute significantly to the early detection of breast cancer.

Correction Method of Slit Modulation Transfer function on Digital Medical Imaging System (디지털 의료영상에서 슬릿법에 의한 Modulation Transfer Function의 보정방법)

  • Kim, Jung-Min;Jung, Hoi-Woun;Min, Jung-Whan;Im, Eon-Kyung
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.133-139
    • /
    • 2006
  • By using CR image pixel data, We examined the way how to calculate the MTF and digital characteristic curve. It can be changed to the text-file(Excel) from a pixel data which was printed with a digital x-ray equipment. In this place, We described the way how to figure out and correct the sharpness of a digital images of the MTF from FUJITA. Excel program was utilized to calculate from radiography of slit. Digital characteristic curve, Line Spread Function, Discrete Fourier Transform, Fast Fourier Transform digital specification curve, were indicated in regular sequence. A big advantage of this method, It can be understood easily and you can get results without costly program and without full knowledge of computer language. It shows many different values by using different correction methods. Therefore we need to be handy with appropriate correction method and we should try many experiments to get a precise MTF figures.

  • PDF

구내 방사선 촬영에 있어서 Film과 Digital sensor에 따른 피폭선량의 차이에 대한 비교

  • Kim, Ju-Yeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.45-49
    • /
    • 2005
  • 목적 : 기존 구내 방사선 촬영에서 사용되었던 Film에서의 노출선량과 Digital Sensor를 이용한 구내 디지털 촬영에서의 노출선량을 비교하여 현재 광범위 하게 사용 되어지고 있는 Digital Sensor가 환자의 피폭선량을 감소하는데 기여하는 정도를 알아본다. 대상 및 방법 : 치아 우식증이 없는 5개의 구치부 치아를 선택하여 석고 블럭에 매식한 후 교합면과 인접면에 우식병소들을 형성하였다. 이를 필름(Kodak Insight; IS, Kodak Co, USA)과 Digital Sensor(Kodak RVG 6000; Kodak Co, USA)에 XCP Instrument(Rinn Co, USA)를 사용하고, 전면에는 조직등가물질인 Acrylic Resin Block 20mm를 설치하였다. Acrylic Resin Block의 관구 측면 에서는 조사선량계를 부착하여 단계별로 변화시키는 노출조건에 대한 조사선량을 측정하였다. 그리고 이렇게 얻어진 영상을 3명의 방사선학 전공의와 1명 의 보존과 전공의가 평가를 하였다. 결과 : Film과 Digital Sensor를 가지고 촬영한 영상을 분석한 결과 노출선량에서도 Digital Sensor는 Film 노출선량과 비슷한 결과를 도출해 낼 수 있었다. 그러나 Digital Sensor로 촬영된 영상의 경우에는 Film 경우보다 좀더 효과적으로 조사선량을 판단 할 수 있었으며, 또한 영상 판독시 필름보다 폭 넓게 응용 할 수 있었다. 결론 : 본 연구에서는 선량 변화에만 의존하는 것이 아니라 Digital Sensor로 촬영시 영상 조절을 병행한다면 좀더 정확하고 효과적인 진단 활동에 도움이 될 수 있을 것으로 사료된다.

  • PDF

image processing and development of digital X-ray using CCD Camera (CCD 카메라를 이용한 디지털 X-ray개발과 영상처리에 관한 연구)

  • Jeong, Jae-Sang;Gang, Yong-Cheol;HwangBo, Soung
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2795-2797
    • /
    • 2003
  • 기존의 X-ray System을 보면 방사선 소스와 방사선을 가시광선으로 변환시키는 형광판, 그리고 이 발광된 빛을 증폭시키는 작용을 하는 영상 증배관과 필름으로 구성된다. 이에 따른 시스템의 부피와 한 장의 필름이 나오기까지의 과정 등이 매우 번거롭다. 이 시스템을 저비용의 디지털 X-ray 시스템으로 대체함에 있어서 형광판과 디지털 CCD카메라를 이용하여 저가이면서 시스템 자체는 간소화시킨 X-ray시스템을 개발하고자한다. X-ray이미지는 형광판의 밀도와 카메라의 분해능에 따라 그 해상도가 결정이 되지만, 이번연구에서는 8bit의 분해능에 $1300{\times}1030$의 해상도를 갖는 Monochrome Digital 카메라를 사용하고, 기존 시스템에 사용되던 간접촬영용 형광판을 사용하였다. 기존시스템의 영상증배관을 배제시켜 후처리에 중점을 두어 시스템은 간소화하고, 저비용을 실현시켰다.

  • PDF

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography (디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측)

  • Park, Yeo-Jin;Joo, Young-Cheol;Lee, Il-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

Effects of Tube Voltage and Tube Current on Exposure Index : Focused on Radiographic Images of Cone Pyramid Phantom (관전압과 관전류량이 노출 지수에 미치는 영향 : 원뿔형 피라미드 팬텀 방사선영상 중심으로)

  • Seoung, You-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.749-755
    • /
    • 2019
  • In this study, we investigated the effects of tube voltage (kVp) and tube current (mAs) on an exposure index (EI) applied to a digital radiography. There used an inverter type digital X-ray generator and an image receptor (IR) utilized a portable wireless detector without a grid. Radiographic images were acquired using a cone pyramid phantom produced using a 3D printer. The X-ray tube voltage was increased from 40 kVp to 120 kVp with 10 kVp increment, and the tube current was increased from 1 mAs to 128 mAs with the twice increment. As a result, kVp had logarithmic relationship with the EI as high $R^2$ value, and mAs had a very high linear relationship too. Also, there was a high correlation between the area dose and the EI of the IR, with the $R^2$ value being 0.76 or more. In conclusion, it had showed that mAs affected the EI linearly, and that it could be advantageous to adjust the easy-to-predict mAs to maintain proper image qualities.

Development of Radiation Image Sensor using Heterojunction (이종접합을 이용한 방사선 영상 센서 개발)

  • Kim, Young-Bin;Yun, Min-Seok;Kim, Min-Woo;Jung, Suk-Hee;Kim, Yoon-Suk;Oh, Kyung-Min;Nam, Sang-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.27-35
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using double layer technique tio decrease dark current. High efficiency material in substitution for a-Se have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using Hetero junction already used as solar cell, semiconductor. Particle-In-Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in PIB method. To make up for the weak points, double layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity is measured to evaluate double layer radiation sensor material.

  • PDF