• Title/Summary/Keyword: 디지털 계전기

Search Result 91, Processing Time 0.026 seconds

An Improvement of Digital Distance Relay Reliability considering Mutual Coupling in Transmission Lines (송전선로에 있어서 Mutual Coupling을 고려한 디지털 거리계전기의 신뢰도 향상)

  • Choi, Seok-Min;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1025-1027
    • /
    • 1997
  • In this paper, the digital distance relay of transmission lines under fault conditions is discussed. Distance relay is used to protect transmission lines. The principle of distance relay is well-known ; the impedance measured by a relay is Proportional to the distance from the relay to the fault. Hence, by measuring the impedance, it can be determined whether the line is faulted or not. Unfortunately, the measurement of the fault distance is distorted by Mutual Coupling. To implement more reliable and practical digital distance relay, the mutual coupling effect has to be considered.

  • PDF

A Development of Electronic Type Relay for Low Voltage Circuit Breaker based on Digital Signal Processing (디지털 신호 처리 기반 저압 차단기용 전자식 계전기 개발)

  • Park, Byung-Chul;Shon, Jong-Man;Song, Sung-Kun;Shin, Joong-Rin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.81-88
    • /
    • 2013
  • A low voltage circuit breaker protects electrical equipments from over current and short faults of system by cutting the power supply. The breaker use a thermal magnetic type trip device from the past. In recent years, electronic type relays are applied due to useful functions and services. The purpose of this development is full digitalizing of relay functions of a low voltage breaker. It includes separation of current sensor from current transformer, digital signal processing, high speed relaying, and voltage measuring for power meter. The suggestions are tested and implemented by making prototype and testing its all relay functions.

Digital Adaptive Distance Relay for Transmission Line Protection (송전선로 보호용 디지털 지능형 거리계전기)

  • Jeong, Chang-Ho;Kim, Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.9
    • /
    • pp.411-416
    • /
    • 2001
  • Distance relay is the most widely used in transmission line protection because it is applicable not only as main protection but also as back-up protection. However, the protection range of the distance relay is always fixed in the unchangeable operating range while the power system varies, and therefore the distance relay is the device that is the highly influenced by the power system changes. In this regard, this paper describes an approach to minimize the mal-operation of the distance relay due to the power system changes through changing protection range of the distance relay into optimal condition in response to the load variation and power system condition. Also mal-function of the distance repay in case of high resistance ground faults could be minimized through modeling the protection range into quadratic function.

  • PDF

Efficiency Improvement of Digital Protective Relay for Power Transformer Using DMA Controller of DSP (DSP의 DMA 제어기를 이용한 변압기용 디지털 보호계전기의 성능향상)

  • 권기백;서희석;신명철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.11
    • /
    • pp.647-654
    • /
    • 2003
  • As electrical power system has become complicated and enlarged to cope with the increasing electric demand, it has to be expected that higher speed, higher reliability, higher function and higher arithmetic ability in protective relay should be realized. Therefore, in this papers, by hardware design and implementation used DMA controller that transfer blocks of data to any location in the memory map without interfering with CPU operation, CPU utilization is increased effectively, as a result it made possible to implement multi-function digital protective relay which has high trust and high function of protection as well as control and metering for power transformers using single processor(DSP).

A PC Based Tester for Digital Relay (PC 인터페이스에 의한 디지털 계전기 시험기)

  • Park, Chul-Won;Shin, Myong-Chul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.11
    • /
    • pp.536-541
    • /
    • 2000
  • Digital protective relay in power system play a prominent part. Simulators for the relay test were introduced in early 1980's. A number of open loop designs have been developed and recently, several developments of real-time simulators have been reported. But they are very high cost. And then they are difficult to apply for relay testing in small business. This paper presents the structure of low cost and performance of a new pc based tester for digital protective relay testing. The proposed tester was simulated of off-line with fault transient signals obtained from EMTP.

  • PDF

Digital Distance Relay with Adaptive Protection Zone (Adaptive보호범위를 가진 송전선로 보호용 디지털 거리계전기)

  • Jung, Chang-Ho;Lee, Jae-Gyu;Jung, Byung-Tae;Ahn, Bok-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.893-895
    • /
    • 1998
  • This paper presents the adaptive setting method of distance relay under the single line ground fault. The apparent impedance measured at the relaying point and actual impedance is different because of fault resistance and various prefault loading condition. For a resistance earth fault detection, relay setting zone is adaptively changed with measured load current and bus voltage at the relaying point to avoid maloperation.

  • PDF

A Study on the Zone Setting of Digital Distance Relay (디지털 거리계전기의 Zone 설정에 관한 연구)

  • Lee, Jae-Gyu;Jung, Chang-Ho;Jung, Byung-Tae;Ahn, Bok-Shin;Kim, Sok-Il
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.946-948
    • /
    • 1998
  • The distance relay is very important for transmission line protection. A quadrilateral zone shape is used mainly for a modern digital distance relay. The shape of quadrilateral is vendor specific. At the stage of design, the shape is determined considering all possible types of faults and diverse configurations of system. Also this type relay must be designed to avoid the operation by a sound phase at single-Phase-to-ground fault, by a sound phase at two-phase-to-ground fault. The effect of a source impedance and a load impedance is another important factor to design. In this paper, a reliable zone shape which is appropriate for the KEPCO's transmission system is provided.

  • PDF

An Improvement of Digital Distance Relay Reliability using Neural Networks (신경회로망을 이용한 디지털 거리계전기의 신뢰도 향상)

  • Lee, Myoung-Soo;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.949-951
    • /
    • 1998
  • Because of the zero sequence mutual coupling of parallel lines, the distance calculation performed by a distance relay is incorrect. To achieve correct operation, the relay has to use not only the measured quantities of faulty line, but also the zero sequence current of healthy line. But the zero sequence current of the healthy line cannot be always measured. Therefore, we propose the neural network method to estimate the zero sequence current and the criterion to determine whether faulty line or not.

  • PDF

A Study on the Digital DC Protection Relay through with Field Adoption Test in the DC Distribution System (직류급전시스템 시험적용 사례를 통한 디지털 직류 보호계전기에 관한 연구)

  • Cha, Kwang-Seok;Ko, In-Suk;An, Tae-Pung;Min, Byung-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.606-615
    • /
    • 2006
  • This study identifies the comparison of Technical specification and Characteristics of DC Protection Relay(ETCPU200) used in DC Distribution System in Korea. ETCPU200 has completed Field Test and approved its capability by finding out causes of recent operations through lately developed digital DC protection relay in parallel operation at Maebong-Substation, Nakseongdae-Substation, Euljirosaga-Substation, Jegi-Substation and Chongryangri T/P area. It also examines additional features for efficient System Analysis and Operations.

  • PDF

A PC based Simulator for Digital Protective Relay Testing (PC 인터페이스를 이용한 디지털 보호계전기 시뮬레이터)

  • Park, Chul-Won;Seo, Jong-Wan;Jung, Ho-Sung;Shin, Myong-Chul;Lee, Bock-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2902-2904
    • /
    • 1999
  • Protective relay in power system play a prominent part, Simulators for the relay test were introduced in early 1980's, A number of open loop designs have been developed and Recently, several developments of real-time simulators have been reported. But they are very high cost. And then they are difficult to apply for relay testing in small business. This paper presents the structure and performance of a new pc based simulator for digital protective relay testing.

  • PDF