• Title/Summary/Keyword: 디지털정확도

Search Result 622, Processing Time 0.025 seconds

A review on the accuracy assessment methods of 3-dimensional digital dental models (디지털 치과모형의 정확도 평가 방법에 대한 고찰)

  • Park, Ji-Su;Lim, Young-Jun;Lee, Jungwon;Kim, Bongju
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.55-63
    • /
    • 2019
  • The aim of this article was to review various methods used to evaluate the accuracy of digital dental models. When evaluating the accuracy of digital models, the errors can be reduced by educating examiners and using artificial landmarks. The accuracy evaluation methods of digital dental models are divided into linear measurement, 2-dimensional cross-sectional analysis, and 3-dimensional best fit measurement. As the technology of scanners develops, many studies have been conducted to compare the accuracy of digital impression and conventional impression. According to improvement of scan technologies and development of 3-dimensional model analysis software, the ability to evaluate the accuracy of digital models is becoming more efficient. In this article, we describe the methods for evaluating the accuracy of a digital model and investigate effective accuracy analysis methods for each situation.

3D Positioning Accuracy Estimation of DMC in Compliance with Introducing High Resolution Digital Aerial Camera (고해상도 디지털항공사진 카메라 도입에 따른 DMC의 3차원 위치결정 정확도 평가)

  • Hahm, Chang-Hahk;Chang, Hwi-Jeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.1
    • /
    • pp.743-750
    • /
    • 2009
  • Since aerial photogrammetry by analog camera began in 1972, recently, high resolution digital camera is actively introduced to improve efficiency of aerial photogrammetry. This study investigated the 3D positioning accuracy of DMC(Digital Mapping Camera) among various high resolution aerial digital cameras to be developed for photogrammetry. For the research, we installed control points in test field around Incheon, and acquired analog and digital aerial photographs. By comparing 3D positioning accuracies of analog and digital photographs, there are few difference between two cameras, and the 3D positioning accuracies of two cameras was somewhat increased in case of aerotriangulation using additional control points based on GPS/IMU EO data.

The Precision Measurement of Stone′s Surface Roughness by Digital Close-Range Photogrammetry (수치근접사진측량에 의한 조경석의 표면 거칠기 정밀측정)

  • 이효성;안기원
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2000.10a
    • /
    • pp.40-50
    • /
    • 2000
  • 본 연구에서는 Rolleiflex 6006 측정용 카메라로 촬영된 사진과 DCS 420 디지털 카메라로부터 촬영된 화상을 이용, 수치근접사진측량을 실시한 후, 조경석의 표면 거칠기 측정 정확도 향상을 위하여 최소제곱법으로 기준평면 또는 기준곡면을 찾아 사용하는 방법을 연구하였으며, 조경석 표면의 연마 이전과 연마 이후의 표면 거칠기를 측정, 비교하여 연마후의 거칠기 감소크기를 산출하고, 측정 정확도를 알아보기 위하여 거칠기가 거의 없는 평면인 돌과 곡면인 돌의 표면 거칠기를 측정한 결과, 그 거칠기를 기대정확도 이상인 각각 $\pm$0.lmm 및 $\pm$0.2mm의 정확도로 측정할 수 있었다. 또한 측정용 카메라인 경우 렌즈왜곡 보정에 있어서 검정자료를 토대로 기준점을 사용하지 않는 직접보정방법인 Newton-Raphson법을 적용하여 기하학적 정확도가 향상된 수치사진화상을 얻을 수 있었으며, DCS 420 디지털 카메라와 윈도우 운영체계인 Visual basic 6.0을 이용하여, 표면 거칠기 측정시스템을 구축함으로써 연마이전 조경석과 연마이후 조경석에 대한 표면 거칠기 및 형상을 정밀 측정할 수 있는 수치근접사진측량기법을 제시할 수 있었다.

  • PDF

Updating Building Layer of Digital Map Using Airborne Digital Camera Image (디지털항공영상을 이용한 수치지도의 건물레이어 갱신)

  • Hwang, Won-Soon;Kim, Kam-Rae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.4
    • /
    • pp.31-39
    • /
    • 2007
  • As the availability of images from airborne digital camera with high resolution is expanded, a lot of concern are shown about the production of orthoimage and digital map. This study presents the method of updating digital map using orthoimage from airborne digital camera image. Images were georectified using GPS surveying data. For the generation of orthoimage, Lidar DEM was used. The absolute positional accuracy of orthoimage was evaluated using GPS surveying data. And that of the building layer of digital map was estimated using the existed digital map at the scale of 1:1,000. The absolute positional accuracy of orthoimage was as followed: RMSE in X and Y were ${\pm}0.076m$ and ${\pm}0.294m$. The RMSE of the building layer were ${\pm}0.250m$ and ${\pm}0.210m$ in X and Y directions, respectively. The RMSE of the digital map using orthoimage from Aerial Digital Camera image fell within allowable error range established by NGII. Consequently, updating digital map using orthoimage from Aerial Digital Camera image can be applied to various fields including the construction of the framework data and the GIS of local government.

  • PDF

A Study comparing accuracy methods of collision·stranding, and route planning service for small vessels (소형선박 대상 충돌·좌초 및 추천항로 서비스 정확도 비교 방안 연구)

  • Jong-Hwa Baek;Younghoon Yang;Junrae Cho;Deuk-Jae Cho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2023.05a
    • /
    • pp.210-211
    • /
    • 2023
  • To reduce maritime accidents and improve safety for domestic ships, the government has developed and is operating the Korean e-Navigation Service. The ship collision and grounding monitoring service and the route planning service were developed based on the experience of captains and navigators who navigated large ships. However, in Korea, small ships account for a large portion of the users of these services, so there are various difficulties and additional requirements for applying services based on large ships to small ships. To improve this, a data science-based algorithm model using maritime digital traffic information is being developed for small ships, and it is important to evaluate the performance of the developed model and compare its accuracy with existing services. In this study, we propose a performance evaluation method for the developed algorithm model and study how to compare and evaluate its accuracy with existing e-navigation services.

  • PDF

Updating Digital Map using Images from Airborne Digital Camera (항공디지털카메라 영상을 이용한 수치지도 갱신)

  • Hwang, Won-Soon;Kim, Kam-Rae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.6_2
    • /
    • pp.635-643
    • /
    • 2007
  • As the availability of images from Airborne Digital Camera with high resolution is expanded, a lot of concern are in the production and update of digital map. This study presents the method of updating the digital map at the scale of 1/1,000 using images from Aerial Digital Camera. Geometric correction was completed using GPS surveying data. For digital mapping, digital photogrammetric system was utilized to digitize buildings and roads. The absolute positional accuracy was evaluated using GPS surveying data and the relative positional accuracy was evaluated using the digital map produced by analytical mapping. The absolute positional accuracy was as follows: RMSE in X and Y were ${\pm}0.172m\;and\;{\pm}0.127m$, and average distance error was 0.208m. The relative positional accuracy was as follows: RMSE in X and Y were ${\pm}0.238m\;and\;{\pm}0.281m$, and average distance error was 0.337m. Accuracies of updating digital map using images from airborne Digital Camera were within allowable error established by NGII. Consequently, images from airborne Digital Camera can be used in various fields including the production of the national basic map and the GIS of local government.

Analysis of Direction Finding Accuracy for Amplitude-Phase Comparison and Correlative Interferometer Method (진폭-위상 복합비교 기법과 상관형 위상비교 기법의 방향탐지 정확도 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.195-201
    • /
    • 2016
  • In this paper, we present the direction finding accuracy of correlative interferometer method and amplitude-phase comparison method. Spiral antennas are used for amplitude-phase comparison method and blade antennas are used for correlative interferometer method. Those are made for uniform circular array (UCA) direction finding antenna systems. We simulate the accuracy of azimuth angle with 3 antennas UCA when SNR is 20 dB and baseline is 0.5 wave length. Correlative interferometer method has better accuracy than amplitude-phase comparison method.

Reliability Measurement Technique of The Eye Tracking System Using Gaze Point Information (사용자 응시지점 정보기반 시선 추적 시스템 신뢰도 측정 기법)

  • Kim, Byoung-jin;Kang, Suk-ju
    • Journal of Digital Contents Society
    • /
    • v.17 no.5
    • /
    • pp.367-373
    • /
    • 2016
  • In this paper, we propose a novel method to improve the accuracy of eye trackers and how to analyze them. The proposed method extracts a user profile information created by extracting gaze coordinates and color information based on the exact pupil information, and then, it maintains a high accuracy in the display. In case that extract the user profile information, the changes of the accuracy for the gaze time also is estimated and the optimum parameter value is extracted. In the experimental results for the accuracy of the gaze detection, the accuracy was low if a user took a short time in a specific point. On the other hand, when taking more than two seconds, the accuracy was measured more than 80 %.

Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication (총의치 제작을 위한 무치악 디지털 모형의 정확도 평가)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.393-398
    • /
    • 2015
  • One of the most critical causes in determining the clinical outcomes of dental prostheses is the validity of models. However, studies that evaluated validity of digital models are few. The objectives of this study were to evaluate validity of edentulous digital models for full denture fabrication. Twenty stone models (edentulous model) were manufactured and scanned by dental blue light emitting diode scanner. Twenty digital models were manufactured. Six linear distances (inter-canine distance, inter-molar distance, two dental arch lengths (right, left), two diagonal of dental arch lengths (right, left) were measured for validity evaluation. The measurements of distances of stone models were used by digital vernier caliper and digital models were used by computer program. The mean${\pm}$deviations values of six distances were calculated. The means were compared by the Mann Whitney U test (${\alpha}=0.05$). All statistical analysis were performed using IBM SPSS Statistics ver. 20.0. Although digital models were smaller than stone models in six distances, there were no significant differences (p>0.05) and non exceeded the clinical acceptable range. The edentulous digital models for full denture fabrication can be considered clinically acceptable.

Evaluations of the Accuracy and Reliability of Measurements Made on White Light Scanner-based Dental Digital Models (백색광 스캐너로 채득된 치과용 디지털모형의 정확도와 신뢰도 평가)

  • Kim, Ki-Baek;Kim, Jae-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.357-364
    • /
    • 2012
  • Dental scanner-based dental digital models have been developed that have the potential to replace conventional stone model. The aim of this study was examine the accuracy and reliability of measurements made on digital models. A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the white light scanner(Identica, korea). One examiner individually measured 6 parameters on the conventional model and the digital models on two occasions. The student's t-test for paired samples and intra-class correlation coefficient(ICC) were used for statistical analysis. At the intra-examiner reliability of measurement, ICC at the stone and digital models were 0.75 and 0.87. The mean difference between measurements made directly on the stone models and those made on the digital models was 0.11-0.23mm, and was statistically significant(P<0.05). These in vitro studies show that accuracy of the digital model is similar to that of the stone model. These results will have to be confirmed in further clinical studies.