• Title/Summary/Keyword: 디스플레이 픽셀

Search Result 72, Processing Time 0.029 seconds

Stereo Object Tracking System using Multiview Image Reconstruction Scheme (다시점 영상복원 기법을 이용한 스테레오 물체추적 시스템)

  • Ko, Jung-Hwan;Ohm, Woo-Young
    • 전자공학회논문지 IE
    • /
    • v.43 no.2
    • /
    • pp.54-62
    • /
    • 2006
  • In this paper, a new stereo object tracking system using the disparity motion vector is proposed. In the proposed method, the time-sequential disparity motion vector can be estimated from the disparity vectors which are extracted from the sequence of the stereo input image pair and then using these disparity motion vectors, the area where the target object is located and its location coordinate are detected from the input stereo image. Basing on this location data of the target object, the pan/tilt embedded in the stereo camera system can be controlled and as a result, stereo tracking of the target object can be possible. From some experiments with the 2 frames of the stereo image pairs having $256\times256$ pixels, it is shown that the proposed stereo tracking system can adaptively track the target object with a low error ratio of about 3.05 % on average between the detected and actual location coordinates of the target object.

Stereo Object Tracking and Multiview image Reconstruction System Using Disparity Motion Vector (시차 움직임 벡터에 기반한 스데레오 물체추적 및 다시점 영상복원 시스템)

  • Ko Jung-Hwan;Kim Eun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.166-174
    • /
    • 2006
  • In this paper, a new stereo object tracking system using the disparity motion vector is proposed. In the proposed method, the time-sequential disparity motion vector can be estimated from the disparity vectors which are extracted from the sequence of the stereo input image pair and then using these disparity motion vectors, the area where the target object is located and its location coordinate are detected from the input stereo image. Being based on this location data of the target object, the pan/tilt embedded in the stereo camera system can be controlled and as a result, stereo tracking of the target object can be possible. From some experiments with the 2 frames of the stereo image pairs having 256$\times$256 pixels, it is shown that the proposed stereo tracking system can adaptively track the target object with a low error ratio of about 3.05$\%$ on average between the detected and actual location coordinates of the target object.

온도 스트레스에 의한 Organic Light Emitting Diode 전기적 특성

  • Park, Hyeon-Ae;Choe, Pyeong-Ho;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.453-453
    • /
    • 2012
  • 최근 디스플레이 시장에서는 저전력 자발광 소자인 OLED가 많은 관심 속에 연구 진행 되고 있다. 높은 효율과 투명, 플렉서블 디스플레이가 실현 가능한 OLED 소자는 초기 수명감소, 저전압구동 및 신뢰성에 대한 문제점을 개발 중에 있기에 많은 가능성을 현실화 하지 못하고 있다. 따라서 본 연구에서는 OLED소자의 역방향 반송자 회복 수명을 측정함으로써 스트레스에 의한 소자 열화를 전기적으로 분석하는 방법을 제시하고자 한다. 우선 5cm5cm의 면적에 네 개의 픽셀이 들어가는 후면 발광 Blue OLED를 제작하고 $-40^{\circ}C$부터 $100^{\circ}C$까지 $10^{\circ}C$간격으로 온도 스트레스를 주어 수명을 측정하였다. 전원공급기를 사용하여 직류 전압을 2V 인가하고 함수 발생기를 사용하여 +3V, -0.5V의 구형파를 500 kHz 주파수로 인가하였다. 이러한 조건으로 측정된 소자는 오실로스코프를 이용하여 전압 회복시간을 측정하고 온도 스트레스에 따른 수명을 산출하였다. $-40^{\circ}C$일 때 는 약 1.92E-7s이고 $100^{\circ}C$일 때 는 약 1.49E-7s로 약 0.43E-7s정도 감소하였다. 양의 전압이 인가되었을 때의 소자 내부의 전압은 온도가 증가함에 따라 꾸준히 감소하였고, 이에 따라 또한 꾸준히 감소하였다. 그러나 음의 전압이 인가되는 부분에서는 무설 전류에 의하여 음의 방향으로 흐르게 되는 전압의 절대값이 꾸준히 증가하였고 대체적으로 온도가 증가함에 따라 그래프가 아래로 이동하는 현상이 관찰되었다. 이러한 경향은 이상적인 다이오드의 반송자 축적 식을 통하여 온도가 증가함에 따라 가 증가하는 것과 관련이 있음을 확인하였다. 따라서 다수 층의 레이어로 이루어진 OLED소자의 열적 스트레스에 대한 수명 변화의 물리적 조건이 이상적인 다이오드 특성에 부합한다는 것을 확인하였다.

  • PDF

A Method of Gray Level Shape-Based Interpolation in Medical Image (의학 영상에서의 그레이 수준 형태 기반 보간 기법)

  • Sung, Won;Kim, Eui-Jung;Park, Jong-Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.520-522
    • /
    • 2002
  • 오늘날 CT나 MR등을 통한 의학 영상 기술과 컴퓨터 성능의 향상으로 인체 내부 장기의 영상을 비교적 용이하게 얻을 수 있으며 얻어진 영상 정보는 컴퓨터로 수치화 되므로 데이터의 조작 및 가공이 용이하다. 그러나, 이렇게 얻어진 의학 영상들은 보통 2차원적 슬라이스 image 형태로 얻어진다. 일반적으로 슬라이스 사이의 간격은 조사량 등 여러 문제 때문에, 항상 동일한 간격을 유지하고 있지 않은 경우가 많으며 슬라이스 사이 간격이 슬라이스 내의 픽셀 간격보다 큰 경우가 대부분이다. 이러한 image로부터 3차원적 디스플레이나, 조작, 분석을 하기 위해서는 같은 간격의 image를 얻어야 한다. 이러한 이유로 인하여 보간(Interpolation) 기법이 의학 영상 분야에서 많이 사용된다. 본 논문은 명태-기반 보간 방법을 gray-scale image에 적용이 가능하도록 확장한 그레이 수준 형태 기반 보간 알고리즘을 구현하였다. 그리하여, 본 논문이 제안한 알고리즘을 슬라이스 간격이 큰 2차원 복부 CT 영상에 적용시켜 다른 보간법들보다 향상된 결과를 확인할 수 있었다.

  • PDF

Design of Pixel Circuit for AMOLED Using Pentacene TFTs (펜타센 TFT를 이용한 AMOLED 픽셀회로 설계)

  • Ryu Gi-Seong;Choe Ki-Beom;Lee Myung-Won;Song Chung-Kun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.6 s.348
    • /
    • pp.1-8
    • /
    • 2006
  • In this paper, we designed a pixel circuit for AMOLED display based on organic thin film transistors and analyzed the operation with SPICE simulation. First, we theoretically designed the pixel circuit with the result of layout for fabricating $32\times32$ AMOLED panel, TFT W/L and capacitance of storage capacitor. And we simulated the designed pixel circuit using HSPICE for analyzing electrical performance. As a result of simulation, we identified the possibility of AMOLED display based on OTFTs.

Implememtation of Fast Rasterizer processing using GPGPU based on SIMT structure (SIMT 구조 기반 GPGPU를 이용한 고속 Rasterizer 구현)

  • Kim, Chiyong
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.276-279
    • /
    • 2017
  • In this paper, SIMT structure based GPGPU (General Purpose Computing on Graphics Processing Units) is used for accelerating the Rasterizer which constitutes the screen of the display device in pixel unit. The GPU has a large number of ALUs, and the processing is very fast because of parallel processing. Therefore, in this paper, we implemented a rasterizer that generates a 3D graphics model using a CPU that performs operations sequentially and a GPU that performs operations in parallel. We confirmed that proposed rasterizer in this paper is 1.45 times better than rasterizer using Intel CPU when generating one frame.

The Implementation Of Field-Sequential Stereoscopic Endoscope System Using LCD shutter (LCD 셔터를 이용한 시분할 입체 복강경 시스템의 구현)

  • Seo, Burm-Suk;Choi, Chul-Ho;Kwon, Byeong-Heon
    • Journal of Digital Contents Society
    • /
    • v.5 no.1
    • /
    • pp.73-78
    • /
    • 2004
  • In this paper we implemented a field-sequential stereoscopic endoscope system that can generate stereoscopic images with different perspective depth using LCD shutter. The stereoscopic image is generated form stereoscopic adapter that has LCD shutter. We have compared the stereoscopic depth of a field-sequential stereoscopic endoscope system with that of the conventional endoscope system. And the implemented system is verified by evaluation the field-sequential stereoscopic image on a Monitor. This system will be use to medical instruments in time.

  • PDF

A study of violet LED chips and white LED lamps (자색 LED 칩 및 백색 LED 램프에 대한 연구)

  • 서종욱;김창연;김희수;노승정
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.235-238
    • /
    • 2003
  • Conventional LED displays use pixels which consist of red, green and blue LEDs of different operation voltages and degradation characteristics. Thus, the circuits are complicated and the display of each color changes independently with the operated time. In order to solve these drawbacks, an LED chip of a short wavelength and an LED lamp with the mixture of red, green, blue fluorescencers and epoxy on the LED chip were studied. The fluorescencers are excited by the light of the LED chip. The LED chip has an active layer of InGaN, a peak wavelength of 408 nm, a FWHM of 13 nm and the CIE index of (0.198, 0.087). White LED lamps were obtained and the CIE index change was observed with the change of the epoxy amount added to the fluorescencers.

Extremely High-Definition Computer Generated Hologram Calculation Algorithm with Concave Lens Function (오목 렌즈 함수를 이용한 초고해상도 Computer Generated Hologram 생성 알고리즘)

  • Lee, Seung-Yeol;Lee, Chang-Joo;Choi, Woo-Young;Oh, Kwan-Jung;Hong, Kee-Hoon;Choi, Kihong;Cheon, Sang-Hoon;Park, JoongKi
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.571-572
    • /
    • 2020
  • 3D 디스플레이 산업에 있어서 홀로그램의 상용화는 여전히 많은 문제점을 가지고 있다. Computer Generated Hologram(CGH)은 홀로그램 분야 중에서도 3D 물체를 생성하는데 여러 가지 강점을 가지고 있지만 큰 해상도를 가진 CGH를 생성하는데 많은 연산시간이 걸려 상업화에 걸림돌이 되고 있다. 이 논문에서는 이를 해결하기 위하여 오목 렌즈 함수를 이용한 초 고해상도 CGH를 생성하는 알고리즘을 이용하여 초 고해상도 홀로그램을 생성하는 방법을 제안하였다. 초 고해상도 CGH를 생성하기 위하여 필요한 일반적인 방법으로 실제로 계산해야 될 CGH의 크기는 4 메가픽셀(2k X 2k) 수준의 저해상도로서, 저사양의 컴퓨터로서도 충분히 빠르고 부담 없이 계산해낼 수 있는 사이즈이다. 생성된 CGH로 Array를 형성한 후, 해당 위치에 알맞은 임의의 오목 렌즈 함수를 곱해줌으로서 임의의 크기 및 복원 거리를 가지는 초고해상도 CGH를 생성할 수 있음을 확인하였다.

  • PDF

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.