• Title/Summary/Keyword: 등온증폭법

Search Result 23, Processing Time 0.025 seconds

Visual detection of porcine circovirus 2 by loop-mediated isothermal amplification (LAMP) with hydroxynaphthol blue dye (육안 판독 등온증폭법을 이용한 돼지 써코바이러스 2형 신속 진단법)

  • Kong, Ho-Chul;Kim, Eun-Mi;Jeon, Hyo-Sung;Kim, Ji-Jung;Kim, Hee-Jung;Park, Yu-Ri;Kang, Dae-Young;Kim, Young-Hwa;Park, Jun-Cheol;Lee, Chang-hee;Yeo, Sang-Geon;Park, Choi-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.3
    • /
    • pp.145-153
    • /
    • 2015
  • In this study, we developed a loop-mediated isothermal amplification (LAMP) with hydroxynaphtol blue dye (HNB) for rapid and direct visual detection of porcine circovirus 2 DNA with high sensitivity and specificity. The LAMP was completed in 40 min at $63^{\circ}C$, and the results of the LAMP can be confirmed by naked eye without any detection process. The sensitivity of the LAMP was 10-fold higher than that of the commercial PCR (cPCR) and real time PCR (rPCR) previously reported. In clinical application, the PCV2 detection rate of the LAMP was the same on porcine tissue samples (75.0%, 36/48) between porcine blood samples (75.0%, 39/52). The PCV2 detection rate (75.0%) of LAMP was higher than those of the cPCR and rPCR (67.3%, 35/52) in blood samples. In conclusion, the LAMP developed in the study could be an useful alternative method for the detection of PCV2 in the swine disease diagnostic laboratories.

Comparison of Polymerase Chain Reaction, Real-time Polymerase Chain Reaction, and Loop-Mediated Isothermal Amplification for the Detection of Cronobacter sakazakii in Milk Powder (분유에 오염된 Cronobacter sakazakii 검출을 위한 중합효소연쇄반응, 실시간중합효소연쇄반응, 등온검출법의 비교)

  • Kim, Young-Joo;Seo, Sheungwoo;Wang, Xiaoyu;Seo, Dong Joo;Lee, Min Hwa;Son, Na Ry;Lee, Bog-Hieu;Choi, Changsun
    • Food Science of Animal Resources
    • /
    • v.33 no.5
    • /
    • pp.610-616
    • /
    • 2013
  • Loop-mediated isothermal amplification (LAMP) is an emerging detection technology for the amplification of DNA under isothermal conditions. The aim of this study was to develop a rapid and reliable LAMP technique for the detection of Cronobacter sakazakii in milk powder. In order to enhance the sensitivity and specificity, LAMP primers targeting outer membrane protein A (ompA) gene of C. sakazakii were designed using Explorer V4 software. Thirty seven C. sakazakii strains and 13 pathogenic microorganisms were used for comparative detection of C. sakazakii using polymerase chain reaction (PCR), real-time PCR, and LAMP. LAMP developed in this study could specifically detect C. sakazakii strains without cross-reactivity with other foodborne pathogens. LAMP products amplified from ompA gene of C. sakazakii were digested with with HhaI and NruI enzyme. The specificity of LAMP was confirmed by restriction fragment length polymorphism (RFLP) analysis. LAMP could detect C. sakazakii within 1 h without bacterial culture and its detection limit was as low as 1 CFU/mL C. sakazakii in milk. In the comparison of the sensitivity, LAMP showed 10,000- and 100-times higher detection limit than PCR or real-time PCR, respectively. Therefore, this study can conclude that LAMP is a rapid and reliable detection technique for C. sakazakii contaminated in powdered milk.

The Detection and Diagnosis Methods of Infectious Viroids caused Plant Diseases (식물체에 감염성 질병을 유발하는 바이로이드 검출 및 진단 방법)

  • Lee, Se Hee;Kim, Yang-Hoon;Ahn, Ji-Young
    • Journal of Life Science
    • /
    • v.26 no.5
    • /
    • pp.620-631
    • /
    • 2016
  • Viroids are about 250-400 base pair of short single strand RNA fragments have been associated with economically important plant diseases. Due to the lack of protein expression capacity associated with replication, it is very difficult to diagnosis viroid diseases in serological methods. For detecting viroid at plants, molecular-based techniques such as agarose gel electrophoresis, polyacrylamide gel electrophoresis (PAGE), DNA-hybridization, blotting analysis and conventional RT-PCR are reliable. Real-time RT-PCR methods that grafted on RT-PCR methods with improved confirmation methods have been also utilized. However, they are still labor-intensive, time-consuming, and require personnel with expertise. Loop-mediated Isothermal Amplification (LAMP) method is a nucleic acid amplification method under the isothermal condition. The LAMP methodology has been reported to be simple, rapid, sensitive and field applicable in detecting a variety of pathogens. The results of LAMP method can be colorized by adding a visible material such as SYBR green I, Evagreen, Calcein, Berberine and Hydroxy naphthol blue (HNB) with simple equipment or naked eyes. The combination of LAMP method and nucleic pathogens, viroids, can be used to realize simple diagnosis platform for the genetic point-of care testing system. The aim at this review is to summary viroid-caused diseases and the simple visible approach for diagnosing viroids using Loop-mediated Isothermal Amplification (LAMP) method.