• Title/Summary/Keyword: 등가구조

Search Result 1,027, Processing Time 0.026 seconds

Noise Exposure Level Measurements for Different Job Categories on Ships (선박의 담당업무에 따른 소음노출레벨 측정에 관한 연구)

  • Im, Myeong-Hwan;Choe, Sang-Bom
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.875-882
    • /
    • 2021
  • To minimize occupational noise induced hearing loss, it is recommended that workers should not be exposed to noise levels exceeding 85 dBA for over 8 h. In the present study, noise exposure levels were measured for seven workers based on their tasks on a training ship. The A-weighted noise exposure level (Lex,24h) was measured by taking into account the A-weighted equivalent continuous sound level (LAeq,i), duration (h) and noise contribution (Lex,24h,i) from the workers' locations. Results are thus obtained for different job categories as follows: officer group Lex,24h=56.1 dB, navigation crew Lex,24h=58.9 dB, navigation cadet Lex,24h=62.0 dB, ship's cook Lex,24h=64.3 dB, engine cadet Lex,24h=91.1 dB, engineer Lex,24h=91.1 dB, and engine crew Lex,24h=95.1 dB. It was determined that the engineers, engine crews, and engine cadets in charge of machinery must wear hearing protection devices. By wearing hearing protection devices when working in highly noisy engine rooms, it is estimated that the noise expose levels could be reduced by the following amounts: engineer Lex,24h=23.1 dB, engine Crew Lex,24h=24.4 dB, and engine cadet Lex,24h=21.5 dB. Moreover, if the no. 2 lecture room and mess room bottom plates in the cadets accommodations were improved to the 64 mm A-60-class floating plates, then further reductions are possible as follows: navigation cadet Lex,24h=4.3 dB and engine cadet Lex,24h=1.8 dB.

Distribution of Mast cells and Nerves in the Developing Postnatal Submandibular and Sublingual Glands of Rats (생후 발생중인 흰쥐의 턱밑샘 및 혀밑샘에서의 비만세포와 신경의 분포양상)

  • Kim, Jae-Gon;An, Soo-Hyeon;Lee, Young-Su;Baik, Byeong-Ju;Cho, Eui-Sic
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.350-364
    • /
    • 1999
  • The distribution of mast cells and nerves were investigated in the submandibular and sublingual glands of postnatal rats, using morphometric, histochemical and immunohistochemical techniques. Mast cells were observed in the submandibular and sublingual glands of postnatal development. Number of mast cells gradually increased in both glands following development. At birth, mast cells were relatively fewer in submandibular gland than those in sublingual gland, and they were mainly distributed in parenchymal tissues. At $2{\sim}4$ weeks, most of the mast cells were observed in the connective tissues, surrounding neurovascular elements, but some mast cells were closely related with the acini of submandibular gland. PGP 9.5 immunoreactive nerve fibers were found in the submandibular and sublingual glands of all developmental age. The nerve fibers were showed in varicose shape, and mainly located in adjacent area of ducts and vascular components of both glands. The number of nerve fibers were increased rapidly until 8 weeks, but they were not increased any more until 24 weeks. Therefore, it is suggested that mast cells and nerve fibers related with each other, and that their interactions may play roles not only in maturation of secretory units but also growth and differentiation of the tubular structures of the rat submandibular and sublingual glands during postnatal development.

  • PDF

Monte Carlo Simulation of the Carbon Beam Nozzle for the Biomedical Research Facility in RAON (한국형 중이온 가속기 RAON의 의생물 연구시설 탄소 빔 노즐에 대한 Monte Carlo 시뮬레이션)

  • Bae, Jae-Beom;Cho, Byung-Cheol;Kwak, Jung-Won;Park, Woo-Yoon;Lim, Young-Kyung;Chung, Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.12-17
    • /
    • 2015
  • The purpose of the Monte Carlo simulation study was to provide the optimized nozzle design to satisfy the beam conditions for biomedical researches in the Korean heavy-ion accelerator, RAON. The nozzle design was required to produce $C^{12}$ beam satisfying the three conditions; the maximum field size, the dose uniformity and the beam contamination. We employed the GEANT4 toolkit in Monte Carlo simulation to optimize the nozzle design. The beams for biomedical researches were required that the maximum field size should be more than $15{\times}15cm^2$, the dose uniformity was to be less than 3% and the level of beam contamination due to the scattered radiation from collimation systems was less than 5% of total dose. For the field size, we optimized the tilting angle of the circularly rotating beam controlled by a pair of dipole magnets at the most upstream of the user beam line unit and the thickness of the scatter plate located downstream of the dipole magnets. The values of beam scanning angle and the thickness of the scatter plate could be successfully optimized to be $0.5^{\circ}$ and 0.05 cm via this Monte Carlo simulation analysis. For the dose uniformity and the beam contamination, we introduced the new beam configuration technique by the combination of scanning and static beams. With the combination of a central static beam and a circularly rotating beam with the tilting angle of $0.5^{\circ}$ to beam axis, the dose uniformity could be established to be 1.1% in $15{\times}15cm^2$ sized maximum field. For the beam contamination, it was determined by the ratio of the absorbed doses delivered by $C^{12}$ ion and other particles. The level of the beam contamination could be achieved to be less than 2.5% of total dose in the region from 5 cm to 17 cm water equivalent depth in the combined beam configuration. Based on the results, we could establish the optimized nozzle design satisfying the beam conditions which were required for biomedical researches.

Correlations of Exogenous and Endogenous Components of Auditory ERPs to Psychometric Measures of Personality (청각 EPR의 내외생적 요소들과 성격의 상관에 관한 연구)

  • Park, Chang-Bum;Lee, Ji-Young;Chi, Sang-Eun;Park, Eun-Hye;Lee, Young-Hyuk;Kim, Hyun-Teak
    • Science of Emotion and Sensibility
    • /
    • v.5 no.4
    • /
    • pp.59-66
    • /
    • 2002
  • This study was proposed as an exploratory study for understanding the biological bases and structures of three personality models: Eysenck's PEN model, Gray's BIS/BAS model, and Costa & McCrae's Five Factor Model, which was chosen as the major descriptive model regardless of its biological bases. Besides, Eysenck's impulsivity scale, IVE, was added to demonstrate the relationship of P and impulsivity. Concerning personality, most previous reports have explored the relationships between P300 and the introversion-extraversion of Eysenck's theory because of its putative biological bases. In the present study, forty-eight undergraduate took four personality batteries (ERQ-R, NEO-Pl-R, BIS/BAS, and IVE). Two types of oddball tasks including different stimulus duration were used to induce ERPs (50ms for task 1, 300ms for task 2). Distributional topographies of correlation coefficients with personality traits and ERP components were drawn, and considered for the consistent interpretation of the personality model structures. Even though all equivalences for extraversion of personality batteries showed similarities for their intra-correlation, their correlations with P3 amplitudes were dissociate. Eysenck's E might not be the proper psychometric measure for elucidating its biological bases. The present study supported the negative relationship of P3 amplitude and extraversion, which is the consensus of previous studies. Neuroticism and Psychoticism showed correlations with the earlier sensory processing components such as N1 and P2. This result might explain the reason why most of studies have failed to find biological connections relating them. Interaction between gender and personality traits should be considered for the interpretation of correlations. Two types of auditory stimulus duration had different sensitivity to personality traits.

  • PDF

Characteristics of Electrode Potential and AC Impendance of Perchlorate Ion-Selective Electrodes Based on Quaternary Phosphonium Salts in PVC Membranes (제4급 인산염을 이용한 과염소산 이온선택성 PVC막 전극의 전극전위와 AC 임피던스 특성)

  • 안형환
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.230-239
    • /
    • 1999
  • Perchlorate ion-selective electrodes in PVC membranes that respond linearly to concentration 106 M were developed by incorporating the quaternary phosphonium salts as a canier. The effects of the chemical structure, the contents of canier, the kind of plasticizer and the membrane thickness on electrode characteristics such as the electrode slope, the linear respone range and the detection limit were studied. With this results, the detectable pH range, selectivity coefficients and AC impedance characteristics were compared and investigated. The perchlorate ion substituents of the quaternary phosphonium salts like tetraoctylphosphonium perchlorate (TOPP) , tetraphenylphosphonium perchlorate(TPPP), and tetrabutylphosphonium perchlorate(TBPP) as a canier were used. The electrode characteristics were better in the ascending order of TBPP < TPPP < TOPP, with the increase of carbon chain length of the alkyl group. Dioctylsebacate(OOS) was best as a plasticizer, the canier contents were better with 11.76 wt% and the optimum membrane thickness was 0.19 mm. Under the above condition, the electrode slope was 56.58 mV/$^P{ClO}_4$,the linear response range was $10^{-1}$\times$10^{-6}$ M, the detection limit was 9.66 x $10^{-7}$ M. The performance of electrode was better than Orion electrode. The electrode potential was stable within the pH range from 3 to 11. The order of the selectivity coefficients for the perchlorate ion was sol < F < Br < 1. With the result of impedance spectrum, it was found that the equivalent circuit for the electrode could be expressed by a series combination of solution resistance, parallel circuit consisting of the double layer capacitance and bulk resistance and Warburg impedance. And solution resistance was almost not appeared and Warburg impedance was highly appeared by diffusion. Then Warburg coefficient was 1.32$\times$$10^74 $\Omega$ $\cdot$ ${cm}^2/s^{1/2}$.

  • PDF

Electrochemical Characterization of Anti-Corrosion Film Coated Metal Conditioner Surfaces for Tungsten CMP Applications (텅스텐 화학적-기계적 연마 공정에서 부식방지막이 증착된 금속 컨디셔너 표면의 전기화학적 특성평가)

  • Cho, Byoung-Jun;Kwon, Tae-Young;Kim, Hyuk-Min;Venkatesh, Prasanna;Park, Moon-Seok;Park, Jin-Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Chemical Mechanical Planarization (CMP) is a polishing process used in the microelectronic fabrication industries to achieve a globally planar wafer surface for the manufacturing of integrated circuits. Pad conditioning plays an important role in the CMP process to maintain a material removal rate (MRR) and its uniformity. For metal CMP process, highly acidic slurry containing strong oxidizer is being used. It would affect the conditioner surface which normally made of metal such as Nickel and its alloy. If conditioner surface is corroded, diamonds on the conditioner surface would be fallen out from the surface. Because of this phenomenon, not only life time of conditioners is decreased, but also more scratches are generated. To protect the conditioners from corrosion, thin organic film deposition on the metal surface is suggested without requiring current conditioner manufacturing process. To prepare the anti-corrosion film on metal conditioner surface, vapor SAM (self-assembled monolayer) and FC (Fluorocarbon) -CVD (SRN-504, Sorona, Korea) films were prepared on both nickel and nickel alloy surfaces. Vapor SAM method was used for SAM deposition using both Dodecanethiol (DT) and Perfluoroctyltrichloro silane (FOTS). FC films were prepared in different thickness of 10 nm, 50 nm and 100 nm on conditioner surfaces. Electrochemical analysis such as potentiodynamic polarization and impedance, and contact angle measurements were carried out to evaluate the coating characteristics. Impedance data was analyzed by an electrical equivalent circuit model. The observed contact angle is higher than 90o after thin film deposition, which confirms that the coatings deposited on the surfaces are densely packed. The results of potentiodynamic polarization and the impedance show that modified surfaces have better performance than bare metal surfaces which could be applied to increase the life time and reliability of conditioner during W CMP.

Community Structure and Health Assessment of Macrobenthos in Tidal Flats along the West Coast of Korea in Spring and Summer (서해안 갯벌의 춘·하계 대형저서동물의 군집구조 및 건강도 평가)

  • Ong, Giho;Jeon, Seung Ryul;Koo, Jun Ho;Park, Jong-Woo;Jeung, Hee-Do;Kang, Jung-Ha;Cho, Yoon-Sik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.4
    • /
    • pp.500-509
    • /
    • 2021
  • This study investigated the characteristics of a macrobenthos community and sediment environment and assessed the health of tidal flats along the west coast of Korea. A survey was conducted from Ganghwa-do to Mokpo, Jeollanam-do in April (spring) and August (summer) 2017, and April (spring) 2018. The sediment grain sizes in the Chungcheongnam-do region were coarser, and the sediment in the Gyeonggi-do·Incheon, Jeollanam-do, and Jeollabuk-do regions were finer. A total of 140 macrobenthic species were collected from this study and using a cluster similarity analysis of the macrobenthos community, they were divided into four groups. Group2 was associated with Manila clam farm stations, and Ruditapes phillipinarum, Nephtys polybranchia and Lumbrineris nipponica were dominant. Group4 included some sites with finer sediment composed relatively, and Eteone longa and Nemertea unid. appeared at a high frequency. From the health assessment of the western tidal flat, the ISEP and BHI indices had a "High status," and the AMBI index had a "Good status." In conclusion, the tidal flats along the west coast of Korea have good ecological health. However, pollution indicator species such as Theora lata and Capitella capitata have appeared in some areas. Therefore, periodic administration and interventions are necessary to prevent deterioration of the tidal flat environment.