• Title/Summary/Keyword: 듀얼에너지

Search Result 38, Processing Time 0.028 seconds

Effect of Nozzle Distance and Angle in the Iron-ore Sintering Dual Burner on Flame Characteristics (철광석 소결용 듀얼 버너의 노즐 간격과 각도가 화염 특성에 미치는 영향)

  • Lee, Young-Jun;Hwang, Min-Young;Kim, Gyu-Bo;Song, Ju-Hun;Chang, Young-June;Jeon, Chung-Hwan
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.163-170
    • /
    • 2010
  • The objective of this study is to investigate the combustion characteristics of dual type of sintering burner as a function of design parameters using lab-scale sintering burner through experimental and numerical approaches. Combustion characteristics were evaluated by the radical method. The numerical model was verified as a temperature using R type of thermocouple at the bed surface. The effect of nozzle distance and angle were performed through the CFD analysis, and the comparison of burner types. As a results, dual type burner has more wider and uniform flame distribution than single type burner. Asymmetry and 45 degree angle condition have been suggested as an optimal condition for the ignition of the sintering bed surface.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

Development of Dual-Window Phantom for Output Measurement of Medical Linacs (의료용 선형가속기 출력측정용 듀얼윈도우 팬텀 개발)

  • Jeong, Dong Hyeok;Kwak, Dong Won;Moon, Young Min;Kang, Yeong-Rok;Kim, Jeung Kee;Lee, Man Woo
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.229-233
    • /
    • 2012
  • A small water phantom (dual-window phantom) was developed to improve the output measurement efficiency of medical linacs. This phantom is suitable for determining the quality index and output dose for high-energy photon beams. The phantom has two opposite windows and two independently rotating axes. The two axes measure the tissue phantom ratio (TPR) and the percentage depth dose (PDD) simply without requiring chamber movement by rotating the phantom around its axis. High-energy photon beams from a Co-60 irradiator and a medical linac were used to evaluate the phantom. The measured quality index is in good agreement with the reference values; the measured and reference values are within 0.2% of each other for the Co-60 gamma rays and within 1.4% for 6 and 10 MV X-rays. This phantom is more practical for routine output measurements, resulting in the prevention of potential human errors.

Usefulness of DECT Application for Compensation of Image Contrast Difference According to CT Contrast Agent Density (CT 조영제 농도에 따른 영상 대조도 차 보상을 위한 DECT 적용의 유용성)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.417-422
    • /
    • 2023
  • In this study, normal saline was diluted with the contrast medium at a certain ratio for the purpose of reducing the image quality poor and side effects caused by the contrast medium during CT examination. At this time, by finding the energy level of DECT that can compensate for the decrease in contrast of the image according to the degree of dilution, the usefulness of applying DECT for compensating the difference in image contrast was investigated through comparative analysis by applying SNR, CNR, and SSIM. As a result, when a dilution ratio of 4 (contrast medium): 6 (normal saline) and the energy level of DECT of 65 keV were applied, the contrast difference was the most similar to that when using the undiluted contrast medium. At this time, SNR was 813.71 ± 37.6, CNR was the highest at 921.87 ± 17.1, and SSIM index was measured at 0.851, which is the most similar to 1. The results of this study are meaningful in providing basic information for finding the appropriate dilution rate and energy level for each examination site through future clinical studies. It is believed that it can be reduced.

Current Sensor Offset Calibration Method using Dual Sensor for trans-less PV Inverter (듀얼 센서를 이용한 무변압기형 태양광 인버터 전류 센서의 오프셋 보정 방법)

  • Hong, Ki-Nam;Choy, Ick;Choi, Ju-Yeop;Lee, Young-Kwon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.182-187
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. Therefore, output current sensor measures sensing value that includes offset again. In this paper we propose new algorithm where two identical forward and reverse sensors are used to calculate the offset in real time. As a result the offset is not correlated with temperature change. The proposed algorithm is verified through PSIM simulation for validity.

  • PDF

Analysis of dual-mode hybrid by using mode change parameter (모드 전환 상수를 이용한 듀얼 모드 하이브리드 해석 방법)

  • Kim, Nam-Wook;Yang, Ho-Rim;Ahn, Kuk-Hyun;Cho, Sung-Tae;Park, Yoeng-Il;Lee, Jang-Moo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.539-542
    • /
    • 2006
  • Many researches about next generation vehicles are trending toward HEV which has better fuel economy than an internal-combustion engine. But existing HEV has some defects at specific running states(eg. highway running It is possible that dual-mode hybrid system overcomes that defects. Mode change parameter, ${\gamma}$ helps to analyse the mode changing of dual mode hybrid and is applied at a numerical analysis on testing the performance. There is an additional constraint when vehicles drive on engine mode. No power assistance of battery applies on engine mode. Because vehicles must be sustained by only engine power while vehicle drives on constant speed mode. At the conclusion of this paper, graphs show the ability of motors that satisfy the equilibrium of the lever system. Designers can roughly determine capacities of the motors, parameters of the lever system by this analysing method.

  • PDF

미래 선도형 에코 성형 시스템 관련 기술의 동향 - 절전구동형 하이브리드 서보 유압프레스 국산화 개발 동향

  • Choe, Ho-Jun;Park, Hun-Jae;Lee, Gwang-Jae;Lee, Jin-U;Gang, Jae-Hun
    • 기계와재료
    • /
    • v.25 no.3
    • /
    • pp.6-15
    • /
    • 2013
  • 유압프레스의 단점을 극복하기 위해서 서보모트를 장착하여 성형속도를 높인 서보 유압프레스를 개발하게 되었으며, 특히나 서보모터를 국내산으로 적용하여 듀얼형으로 유압시스템의 효율성을 높여 최종적으로 개발함으로써 서보 유압프레스를 완전 국산화하였다. 또한 하사점 위치 제어의 용이성을 확보하기 위해 프레스 램용 메인 실린더에 톱니나사부를 만들어 임의의 위치에 정지할 수 있는 정지정도 및 하사점 위치 제어정밀도를 향상시켰으며, 유량의 미세 제어를 통해 프레스 램의 동작성을 개선코자 하였다. 다이쿠션은 메인 실린더와의 연계 제어를 통해 제품의 손상 방지 및 제품 추출의 용이성을 확보하였으며, 소재의 종류나 제품의 형상 특성에 따라 프리모션 제어가 가능한 지식기반형 자율제어 시스템을 적용하였다. 듀얼 서보시스템과 유압펌프가 연계구동함에 따라 기존 유압프레스 보다 약 40%이상의 에너지절감을 달성할 수 있을 것으로 예측되며, 현재 에코머신 인증제도에 대한 논의가 활발한 시점에서 매우 적합하고 필요한 하이브리드형 서보 유압프레스의 국산화 개발 사례라고 하겠다.

  • PDF

A Study on Current Control of Dual Active Bridges Using Virtual Direct Power Control (가상 직접 전력 제어를 이용한 듀얼 액티브 브리지의 전류 제어에 대한 연구)

  • Kang, Ja-Yoon;Lee, Sang-Taek;Shin, Duck-Shick
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.463-464
    • /
    • 2020
  • 전세계적으로 신재생에너지 연구가 개발되면서 DC 마이크로 그리드가 빠르게 확산되고 있다. DC 마이크로 그리드에는 ESS가 필수적으로 적용되는데, ESS 충방전을 위해 양방향 및 절연 기능이 포함한 토폴로지가 적용되어야 한다. 최근에는 절연형 양방향 컨버터로 듀얼 액티브 브리지 토폴로지가 제어에 대한 연구와 함께 많이 적용되어지고 있다. DC 마이크로 그리드에는 여러 DC-DC 컨버터로 구성되어 있어 상위 제어기에서 전류지령 값을 통해 전류제어로 운영된다. 본 논문에서는 가상 직접 전력 제어를 이용하여 빠른 응답을 구현하는 전류제어를 제안하였다. 검증 방법으로는 시뮬레이션을 통해 검증 하였다.

  • PDF

DL-LEACH: Hierarchical Dual-Hop Routing Protocol for Wireless Sensor Network (DL-LEACH : 무선 센서 네트워크를 위한 계층형 멀티 홉 라우팅 프로토콜)

  • Lee, Chang-Hee;Lee, Jong-Yong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.5
    • /
    • pp.139-145
    • /
    • 2015
  • This paper proposes to increase the node energy effienciecy, which rapidly drops during the transmission of LEACH (Low Energy Adaptive Clustering Hierachy), using the method of DL-LEACH (Dual-hop Layered LEACH). By introducing dual-hop method in the data transmission, the proposed single-hop method for short-range transmission and multi-hop transmission method between the cluster heads for remote transmission was introduce. By introducing a partial multi-hop method in the data transmission, a single-hop method for short range transmission method between the cluster heads for remote transmission was introduces. In the proposed DL-LEACH, the energy consumption of cluster head for remote transmission reduces and increases the energy efficiency of sensor node by reducing the transmission distance and simplifying the transmission routine for short-range transmission. As compared the general LEACH, it was adapted to a wider sensor field.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.