• Title/Summary/Keyword: 두 개의 원통

Search Result 51, Processing Time 0.032 seconds

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF

Variations in Morphological and Geochemical Characteristics in Manganese Nodules from the East Siberian Arctic Shelf with Varying Water Depths (동시베리아해 대륙붕에서 산출되는 망가니즈단괴의 수심에 따른 형태학적·지화학적 특성 변화)

  • Hyo-Jin Koo;Hyen-Goo Cho;Sangmi Lee;Gi-Teak Lim;Hyo-Im Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • In this study, we explore the morphological and geochemical characteristics for 440 manganese nodules collected from two different water depths [ARA12B-St52 (150 m, n = 239) and ARA12B-St58i (73 m, n = 201)] on the continental shelf of the East Siberian Sea from the ARA12B expedition in 2021. We also discussed the variations in the characteristics of manganese nodules with varying water depths in the Arctic Sea. The sizes of the nodules are generally greater than 3 cm at both sites. However, there is an obvious difference in the morphology with water depths. For the nodules collected at 150 m, brown-black colored tabular, tube, and ellipsoidal shapes with a rough surface texture are dominant. On the other hand, yellow-brown tabular shapes with a smooth surface texture are common for the nodules collected at 73 m. Furthermore, the slope of trend line between size and weight is significantly different at both sites: particularly, the slopes of nodules at 150 and 73 m are 1.60 and 0.84, respectively. This indicates the difference in the internal structure, porosity, and constituting elements between both nodules. Micro X-ray Flourescence (µ-XRF) results clearly demonstrate that the internal textures and chemical compositions are different with water depths. The nodules at 150 m are composed of a thick Mn-layer and a thin Fe-layer centered on the nucleus, while the nodules at 73 m are alternately grown with thin Mn- and Fe- layers around the nucleus. The average chemical compositions obtained by µ-XRF are 40.6 wt% Mn, 5.2 wt% Fe, and 7.9 Mn/Fe ratio at 150 m, and 10.3 wt% Mn, 19.0 wt% Fe, and 0.6 Mn/Fe ratio at 73 m. The chemical compositions of the nodules at 150 m are similar to those of nodules from the Peru Basin in the Pacific Ocean, while the compositions of the nodules at 73 m are similar to those of nodules from the Cook Islands or the Baltic Sea. The observed morphological and geochemical characteristics of the nodules show a clear difference at the two sites, which indicates that the aqueous conditions and formation processes of the nodules in the Arctic Sea vary with the water depths.

THE INFLUENCE OF THE VITAL BLEACHING AGENTS ON TRANSLUCENCY OF THE BOVINE ENAMEL (생활치 미백제가 우치 법랑질의 투명도에 미치는 영향)

  • Kim, Dong-Jun;Kim, Young-Ju;Kim, Hak-Geun;Park, Eun-Jong;Seo, Eun-Ju;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.178-183
    • /
    • 2005
  • This study was done to evaluate whether vital bleaching agents could influence on the translucency of the bovine enamel. The anterior bovine teeth that were extracted one day before and without any gross discoloration were obtained and then were preserved in physiologic saline. 6 mm cylindrical tooth specimens were fabricated with diamond puncher perpendicularly on labial surface of bovine tooth. After embedded in transparent acrylic resin with labial surface being exposed, they were cut to a thickness of 1.2 mm with low speed diamond saw (Isomat, Buehler Co., Lake Bluff, IL, USA). They were smoothly ground to 1 mm thickness of enamel with sandpaper. 24 specimens were randomly divided into 3 groups and control group respectively. Opalescence (10% carbamide peroxide, Ultradent, South Jordan, USA), Rembrandt (10% carbamide peroxide, DenMat, USA) and Opalescence F (15% carbamide peroxide with fluoride, Ultradent, USA) were applied on labial sides of the bovine enamel for 7 days (bleaching agents were reapplied every 24 hours) and the opposite surface was contacted to cotton that soaked in distilled water. The control group was soaked in distilled water. Three stimulus value X, Y and Z were evaluated with colorimeter (Color ' Color Differencerneter, Model TC-6FX, Tokyo Denshoku Co., Japan) on the labial surface of all specimen three times on white and black background plate before the bleaching agents were applied and on 3rd, 5th and 7th day after applied. The degree of translucency was normally assessed by measuring the inverse property, opacity (contrast ratio). 10% Opalescence, 15% Opalescence-F, and control group showed no significant variation in the translucency of bovine enamel, However Rembrandt decreased the translucency of it (p < 0.01).

Diameter of Autologous Four Strand Hamstring Tendon for Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술을 위해 채취한 네 가닥 자가 슬괵건의 직경)

  • Choi, Jun-Weon;Han, Sang-Ho;Kim, Eu-Gene;Kim, Jong-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.148-152
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the distribution of the diameter of four strand autologous hamstring tendon and to identify the factors related to the diameter. Materials and Methods: Between December 2004 and July 2006, 66 patients underwent anterior cruciate ligament reconstruction using autologous hamstring tendon. Sixty one patients were male and the other 5 patients were female. Both semitendinosus and gracilis tendon were harvested in every case. Harvested two tendons were folded once together to create a four strand double loop graft and were passed through cylindrical sizer to measure their diameter. Parameters such as sex, age, height and weight were analyzed for their correlation with the diameter of the graft. Results: The diameter of the graft ranged from 6 mm to 10 mm. The graft with the diameter of 8 mm was most common and the average diameter of all the grafts was $7.85{\pm}0.92mm$. Seven patients (10.6%) had a graft with the diameter of 6 mm, which is considered too thin to be ideal one. No statistically significant correlation was found between age of the patient and the diameter of the graft. However, the diameter of the graft was significantly correlated with sex, height and weight of the patient. Female patients had a significant tendency to have thinner hamstring tendons. Both small height and light weight of the patients were correlated with thinner hamstring tendons significantly. Conclusion: Sex, height and weight of the patients were the factors that had a statistically significant correlation with the diameter of the graft. Being aware of the risk factors related with harvesting exceedingly thin hamstring tendon prior to anterior cruciate ligament reconstruction, one can utilize wide range of options in selecting an optimal graft.

  • PDF

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Effect of Light-Induced ROS Generation Unit on Inactivation of Foodborne Pathogenic Bacteria in Water (광유도 ROS 발생장치의 세척용수 중 식중독 세균에 대한 불활성화 효과)

  • Choi, Jaehyuk;Kim, Dawoon;Jung, Kyu-Seok;Roh, Eunjung;Ryu, Kyoung-Yul;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.583-590
    • /
    • 2019
  • As the consumption of fresh fruits and vegetables increases, food poisoning caused by foodborne pathogen contamination is not decreasing. To prevent the contamination of produce, a quick and easy, low-cost, environmentally-safe disinfection method that does not affect produce freshness or quality is needed. This study demonstrates a new-concept, circulating-water disinfection system that purifies water by using newly developed 'LED-PS (photosensitizer)-induced ROS generation unit'. Using various types of LED-PS induced ROS generation units, we investigated the conditions for reducing the density of various pathogenic bacteria by more than 3 log CFU / mL in 1 hour. The major operational factors affecting the density reduction of the LED-PS-induced ROS generation unit were analyzed. Depending on bacteria species, the density reduction rate was varied. The effect of the units on reducing the density of Bacillus cereus and Pectobacterium carotovorum subsp. carotovorum was high, but the effect on foodborne bacteria such as Escherichia coli was relatively low. In this circulating water disinfection system, the density reduction effect tended to increase as the flow rate increased and the initial bacterial density decreased. As the amount of PS absorbed beads increased, the density reduction effect increased exponentially in some bacteria. Model 3280, a double cylindrical unit connecting two single cylindrical units, could completely sterilize more than 3 log CFU/mL of B. cereus and P. carotovorum subsp. carotovorum in 30 minutes of LED irradiation.

An Analysis of Body Shapes in Aged Abdominal Obese Women for Apparel Pattern Design (복부비만 노년 여성의 의복패턴설계를 위한 체형연구)

  • Kim, Soo-A;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.12 s.159
    • /
    • pp.1690-1696
    • /
    • 2006
  • The purpose of this study is to provide the basic data useful in designing apparel patterns for aged abdominal obese women. The body measurements of 318 women were taken at random, whose ages were over 60 and fields of action were colleges, sports centers, or business sites in Seoul and the neighboring districts. A total of 33 features in the upper body and lower body were used fer the anthropometric measurement and analysis using anthropometry. The collected measurement data were processed statistically using the SPSS 12.0 program for technical statistical analysis, t-test, frequency analysis, correlation analysis. The results of the study are as follows. 1. Subjects were classified into two groups as a result of analysis for measurement data. It was revealed that 251(about 79 percent) women of total subjects(n=318) have a characteristic of abdominal obese body type and elderly women of these group usually had big abdomen rather than hip. The criteria of abdominal obesity based on waist-hip ratio, WHR(=0.85). 2. Aged abdominal obese women have shown much larger size in most body measurements except items of some vertical length, such as bust ponit-bust point, font interscye, back interscye with circumference and depth of armscye, bust, waist, abdomen and hip while showing no difference in height, biacrominal breadth, hip width, neck shoulder point to breast point, crotch length. 3. Vervaeck index(=100.1) and Rohrer index(=1.7) indicated that the abdominal obese women were fat in overall body. And aspect ratio of waist(=0.86), abdomen(=0.92) and hip(=0.75) also appeared high that the shape of cross sections in those regions was similar to a figure of circle 4. In view of the correlation coefficient between hip circumference and the rest measurement items, and between hip circumference inclusively of the abdomen protrusion and the rest measurement items, there were found some differences for each group. In case of Group (abdominal obese group), the former is smaller than the other. 5. In case of Abdominal obese women, hip circumference inclusively of the abdomen protrusion is more mutually related to the rest items related to make apparel pattern as waist circumference, depth of armscye and so on than what hip circumference is. This result indicated which must be considered hip circumference inclusively of the abdomen protrusion to make apparel patterns for abdominal obese women unlike women of common body types.

Effect of a Freshwater Bivalve (Unio douglasiae) and a Submerged Plant (Potamogeton crispus) on the Growth Inhibition of a Cyanobacterium Oscillatoria sp. (담수패류(Unio douglasiae)와 침수식물(Potamogeton crispus)의 유해 남조 Oscillatoria sp. 성장억제 효과)

  • Kim, Keun-Hee;Kim, Baik-Ho;Park, Myung-Hwan;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.spc
    • /
    • pp.68-76
    • /
    • 2008
  • This study examined the inhibition effects of a freshwater bivalve (Unio douglasiae) and a submerged plant (Potamogeton crispus) on the cyanobacterial bloom (Oscillatoria sp.). The experiment were conducted in aquarium $(50cm{\times}65cm{\times}120cm)$ with lake sediments in the bottom of the aquarium in 10 cm thick. Before the experiments, artificial cyanobacterial bloom was induced with the addition of lake sediment and CB medium. Total 12 transparent acrylic cylinders (${\Phi}19cm$, height 40 cm) were placed in the aquarium, and within which bivalves and plants were placed in various conditions such as the control (C), plant addition (P:5 stems), mussel addition (U:2 individuals), and both mussel and plant addition (PU: the same quantity as used in each treatment). The experiment was conducted in triplicate during 7 days. pH, dissolved oxygen (DO), electric conductivity (EC), salinity, cyanobacterial cell density, chlorophyll-${\alpha}$ concentration, and mussel filtering rate were monitored daily. At the end of the experiment, total phosphorus (TP), total nitrogen (TN), and plant height and weight were measured. Overall, a large degree of cyanobacterial growth inhibition appeared in both P and U treatments, and the effect was highest in the U treatment, followed by P and PU. The combined treatment of both U and P did not show any synergic effects compared to the effect in separated treatment. In all enclosures of the treatments chlorophyll-${alpha}$ (Chl-${alpha}$) concentration decreased until 36 hours after the additions of the plants and mussels. In contrast, Chl-${alpha}$ concentrations increased in PU enclosures after 36 hours. The same trend was shown in the cell density of Oscillatoria. pH and DO gradually decreased until 120 and 144 hours, respectively, in the P and PU enclosures. TP concentration increased in the mussel enclosures (U and PU), while TN concentration largely decreased in the plant enclosures (P and PU). Our results suggest that applied bivalve (Unio) and submerged plant (Potamogeton) seemed to have a potential effect on the growth inhibition of cyanobacteria, but their combined application may have an antagonistic effect to diminish the degree of the inhibition.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF