• Title/Summary/Keyword: 두 개의 원통

Search Result 51, Processing Time 0.022 seconds

Seismic Fragility Analysis of Ground Supported Horizontal Cylindrical Tank (수평원통형 저장탱크의 지진취약도 해석)

  • Chaulagain, Nabin Raj;Sun, Chang-Ho;Kim, Ick-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.145-151
    • /
    • 2019
  • The fragility analyses for the partially filled horizontal cylindrical tank having a flexible wall were conducted to evaluate seismic performance. An equivalent simplified model with two lumped masses representing to impulsive and convective masses was used to represent the liquid storage system. This simplified model was validated by comparing its time history analysis results with the 3D FSI model results. The horizontal tank was analyzed under bi-directional excitations. Seismic fragility curves for the stability were developed in transverse and longitudinal directions. Fragility curves show that seismic damage for the horizontal storage system is more susceptible in the transverse direction.

Pose-invariant Face Recognition using a Cylindrical Model and Stereo Camera (원통 모델과 스테레오 카메라를 이용한 포즈 변화에 강인한 얼굴인식)

  • 노진우;홍정화;고한석
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.7
    • /
    • pp.929-938
    • /
    • 2004
  • This paper proposes a pose-invariant face recognition method using cylindrical model and stereo camera. We divided this paper into two parts. One is single input image case, the other is stereo input image case. In single input image case, we normalized a face's yaw pose using cylindrical model, and in stereo input image case, we normalized a face's pitch pose using cylindrical model with previously estimated pitch pose angle by the stereo geometry. Also, since we have an advantage that we can utilize two images acquired at the same time, we can increase overall recognition performance by decision-level fusion. Through representative experiments, we achieved an increased recognition rate from 61.43% to 94.76% by the yaw pose transform, and the recognition rate with the proposed method achieves as good as that of the more complicated 3D face model. Also, by using stereo camera system we achieved an increased recognition rate 5.24% more for the case of upper face pose, and 3.34% more by decision-level fusion.

Improvement of a Planning Technique Based on Heuristic Target Shaping for Stereotactic Radiosurgery (방사선 수술시 경험적 표적 근사화에 근거한 최적화 방법 개선)

  • Oh Seungjong;Choi Kyoung-Sik;Song Ju-Young;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.176-182
    • /
    • 2005
  • Stereotactic radiosurgery (SRS) is a technique to deliver a high dose to a target region and a low dose to a critical organ through only one or a few irradiation. The SRS must be planned exactly. Currently the surgery plan is peformed by trial and error method. There are many questions about the reliability and reproducibility of the plan result. This study Improve each step of the Oh's method based on heuristic target shaping to obtain the better result. The target was reconstructed using cylinders with same height and the neighbored cylinders were combined according to the difference of each center and diameter. Then, spheres were packed within each cylinders by the packing rules. Two virtual targets were used to compare this method with Oh's method. As a result, the numbers of isocenter were successfully reduced - more than $35\%$ and $26\%$ - without serious differences of proscription isodose to tumour volume ratio (PITV) and maximum dose to proscription dose ratio (MDPD). This technique using cylinder piling and sphere packing will be a helpful tool to planner in stereotactic radiosurgery.

  • PDF

A Study on the Displacement Behavior Safety of Cylindrical Hollow Rollers (원통형 중공롤러의 변형거동 안전성에 관한 연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.1
    • /
    • pp.41-45
    • /
    • 2014
  • This paper presents an analytical study on the displacement behavior safety of cylindrical hollow rollers. Using the finite element method, the hollow roller with Y-shaped column structures between three tubes has been developed to analyze the displacement behavior safety. For the same dimension and weight of two hollow roller models, the displacement behavior safety of a typical hollow roller is lower 4~6.6% than that of the newly designed hollow roller with Y-shaped column structures between three tubes. Thus, this paper recommends Y-shaped hollow roller for increasing the roller strength safety and decreasing a total roller weight, which may save a consuming electrical energy.

Optimal Mounts Design for a Rotation Machine on a Flexible Plate (평판지지 회전기계의 최적마운트 설계)

  • Kim, Joon-Yeop;Lee, Si-Bok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.38-47
    • /
    • 1989
  • The optimal mounting system for reciprocating comperssor supported on a flexible is designed. Four short hollow rubber cylinders are used as mounting pads, and so the thickness, diameter, height and location of the rubber mounts are considered as design parameters. The optimal mounts parameters which give the smallest force transmittance, are obtained by Constrained Rosenbrock Method.

  • PDF

A broadband detection algorithm using cross-correlation of two split beams for cylindrical array sonar (원통형 배열 소나를 위한 두 개의 분리 빔의 상호상관을 이용한 광대역탐지 기법)

  • Kwak, ChulHyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.300-304
    • /
    • 2017
  • In a cylindrical sonar, a conventional broadband energy detector has limitations in the separation of adjacent targets. In this paper, a broadband detection algorithm using cross-correlation is applied to the cylindrical sonar to improve the bearing resolution. The proposed algorithm uses split beamforming before broadband detection processing using cross-correlation to generate half beams. The time delay obtained from the peak of correlation between half beams is used to estimate the bearing of target. Simulations demonstrate the improved performance of the proposed algorithm against the conventional algorithm.

일체형 신형원자로의 증기발생기 개념 설계

  • 김용완;김지호;윤주현;김주평;김종인
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.735-740
    • /
    • 1995
  • 일체형 원자로에는 노심지지원통과 원자로용기 내벽사이의 환형 공간을 나선으로 감는 형태인 일체형 관류식 나선형 증기발생기와 증기발생기를 여러 개의 모듈로 나누어 환형 공간에 배치하는 형태인 모듈형 관류식 직관형증기 발생기가 가장 적합한 것으로 판단되어 두 가지 형태에 대한 개념을 설정하였다. 일체형 관류식 나선형 증기발생기는 전열관 집합체, 지지구조물, 하강유로, 그리고 증기 및 급수 헤더로 구성되어 있다. 모듈형 관류식 직관형 증기발생기는 개개의 모듈이 별도로 운전될 수 있는 12개의 모듈로 구성되며, 원자로용기를 관통하는 배관의 수를 줄이기 위해서 급수관이 증기관의 안쪽에 있는이중배관 개념을 사용한 것이 특징이다. 모듈형 관류식 직관헝 증기발생기가설계 및 제작이 용이하지만 높이를 줄이기 위한 방안으로 두 가지 개념이 조합된 모듈형 관류식 나선형 증기발생기도 검토하였다.

  • PDF

Temperature Analysis of the Cylindrical Structure with Multi-Holes of HANARO Irradiation Test (하나로 조사시험용 다공 원통헝 구조물의 온도해석)

  • Choi Young-Jin;Kang Young-Hwan;Lee Young-Shin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.405-412
    • /
    • 2004
  • During the irradiation tests of material and fuel rod, all components of the cylindrical structure with multiple holes act like heat sources due to high gamma heat and fission heat. The objective of this study is to formulate the general solution for the temperature distribution to estimate the thermal integrity of structure during irradiation tests. For the temperature distribution analysis, the two-dimensional heat conduction theory is used. The unmerical analysis is performed by the commercial finite element analysis code, ANSYS 6.1. If the cylindrical structure with hole number would not exceed three holes, the analysis results and finite element results are good agreement together. For the structure with four holes, the discrepancy between FE results and analysis results of the structural temperature distribution is increased.

Laboratory Experiment of Two-layered fluid in a Rotating Cylindrical container (원통형 이층유체의 회전반 실험)

  • 나정열;최진영
    • 한국해양학회지
    • /
    • v.28 no.1
    • /
    • pp.17-23
    • /
    • 1993
  • A right cylindrical tank with sloping bottom and top (${\beta}-effect$) is filled with two-layered fluid and is put on the rotating table. External fluid of same density as the lower-layer fluid is continuously injected to drive the lower-layer current. By minimizing the interfacial stress between two layers the motion in the lower-layer deformed the shape of interface such that the upper-layer adjust itself to the variations of the interface in terms of its direction of flow patterns .The most significant parameter is the internal Froude Number($F_1$) and when $F_1$ is greater than 6 two-cellular circulation of the upper-layer changes its direction, there by creates a separation of Western boundary current. The separation position moves to the most northward when $F_1$ equals to 6.

  • PDF

Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia (강내온열 치료를 위한 원통형 초음파 치료기 개발)

  • Lee, Rena J.;Hyunsuk Suh
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2002
  • In this study, a cylindrical ultrasound applicator is developed for the treatment of vagina and rectum in combination with high dose rate brachytherapy. A cylindrical transducer (PZT-8, 1=1.5 cm, thickness=1.5mm OD=2.5 cm) was used as an energy source for induction of hyperthermia. Three single-element applicators were constructed to examine the performance of the PZT material. Vector impedance was measured to determine driving frequency. The efficiencies of the elements were determined using a radiation force technique to evaluate the feasibility of using the applicator as a hyperthermia source. A multi-element ultrasound applicator was designed using the PZT-8 material for the treatment of vagina. Results from the vector impedance measurements showed maximum magnitude at 1.78, 1.77, and 1.77 MHz for applicator 1,2, and 3, respectively. The radiation force measurements showed that the acoustic power of 40 watts was obtained in all three elements. The average efficiencies of the elements were 61.4, 65.2, and 54.0% for element 1, 2, and 3, respectively. The designed ultrasound hyperthermia applicator could be used in combination with high dose rate brachytherapy for the treatment of vagina and rectum. The use of this applicator with intracavitary brachytherapy could offer improved tumor control by increasing radiosensitiyity of the tumor.

  • PDF