• Title/Summary/Keyword: 두부고정

Search Result 76, Processing Time 0.033 seconds

A Study on Lateral Loading the Field Test of Pile for Large Diameter Drilled Shaft Pile (대구경 현장타설말뚝에 대한 현장수평재하시험에 관한 연구)

  • Choi, Yong-Kyu;Lee, Min-Hee;Lee, Chung-Sook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.2
    • /
    • pp.33-39
    • /
    • 2004
  • Most of pile foundations are a condition of fixed head on pile, but lateral loading test of pile have performed to free head on generally. This study performed field lateral loading test accompanying lateral displacement by depth of pile for two cases(fixed head and free head) and analyzed lateral behavior of large drilled shaft. Furthermore compared theoretical equation with result of lateral loading test.

  • PDF

A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied (고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구)

  • Choi, Jun-Gu;Kim, Byeong-Gi;Cha, Seon-Hwa;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • This study aim to investigate image characteristics due to focus-grid and head phantom decentering from the armorphos silicon thin film transistor detector the fixed focus-grid is applied, wish to propose right use method of digital medical equipment. Acquired image according to focus-grid and head phantom position decentering using head phantom on armorphos silicon thin film transistor detector the fixed focus-grid is applied. acquired image evaluate pixel value, histogram, plot profile, surface plot using NIB (Image J) image analysis program and compared decentering image with standard image. Mean value and standard deviation value of focus-grid lateral decentering and duplex decentering of focus-grid and head phantom decreased by ratio, consequently increase of horizontality, diagonal decentering. also, deteriorated contrast of image because frequency of high pixel value decreases fairly. according increases decentering, image distortion phenomenon was increase, by next time, pixel mean value of head phantom decentering was no big change but horizontality, diagonal, mean value and standard deviation value of pixel decreased by ratio. Even if increase pixel noise of image because wide latitude and post processing ability of digital detector, radiotechnologist can not recognize. Therefore, radiotechnologist must recognize correctly the photographing factors which increases pixel noise on the grid system installation digital detector and should exam.

  • PDF

Improvement of surface runoff lag algorithm in SWAT (SWAT 모형의 지표유출지체 알고리즘 개선)

  • Kim, Nam Won;Lee, Jeongwoo;Lee, Jung Eun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.299-299
    • /
    • 2016
  • 미농무성에서 개발된 유역수문모형 SWAT을 국내유역에 적용할 경우 일반적으로 일단위 유출 수문곡선의 첨두부가 관측치에 비해 과소하게 모의되는 경향이 있다. 본 연구에서는 이러한 원인에 대해서 고찰하고, 첨두부가 작게 모의되는 문제를 해결하기 위해서 지표유출의 지체와 관련된 서브루틴을 개선하였다. SWAT 모형에서는 지표유출의 지체는 운동파 집중시간(kinematic wave time of concentration)을 변수로 하는 지수형 감쇠함수를 사용하고 있다. 그러나 집중시간 계산식에서 지표유출에 기여하는 초과우량을 6.35mm/hr로 작은 고정값으로 가정하고 있어 큰 호우가 발생한 경우에도 집중시간이 길게 계산되는 구조를 가지고 있다. 이로 인해 지표유출의 지체 효과가 커서 첨두유량이 과소하게 산정되는 문제가 발생한다. 따라서 본 연구에서는 집중시간 계산시 고정값 6.35mm/hr 대신에 일 단위로 모의된 지표유출 발생량이 입력되도록 알고리즘을 수정하였다. 이 방법은 지표유출량의 크기에 따라 집중시간을 가변적으로 산정되게 함으로써 수문곡선의 첨두부를 보다 유연하게 구현할 수 있는 장점이 있다. 모형의 개선 효과를 평가하기 위해서 충주댐 상류유역을 대상으로 개선 전, 후의 일 단위 유출수문곡선의 첨두부를 비교하였으며, 그 결과 큰 홍수가 발생한 기간의 첨두유량이 10 % 이상 증가하는 것으로 분석되었다.

  • PDF

Development of A Fractionated Stereotactic Radiotherapy System (분할 정위방사선 치료 시스템 개발 연구)

  • 이동한;지영훈;이동훈;조철구;김미숙;유형준;류성렬
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2002
  • We invented the newly developed Fractionated Stereotactic Radiotherapy(F.S.R.T) system using combined techniques of couch mounting and pedestal mounting system. Head fixation frame consists of a milled alluminium alloy(duralumin) and is placed to the couch. This frame immobilized patient head using the dental bite, 3.2 mm frontal and occipital thermoplastic mask. To evaluate the coordinate of target isocenter, Brown-Revert-Walls C.T localizer can be attached to this frame. And also, we developed the frame mounting system by developing the modification of pedestal mounting system. This system is fixed to couch floor and can be used to evaluate the isocenteric accuracy of gantry, couch and collimator in Q.A procedure. In order to measure the relocation accuracy, the acrylic phantom and the accurate pointers have been made. The repositioning of the targets in the phantom were estimated by comparing C.T coordinates and E.C.L portal films taken with anterior-posterior and right-left direction. From the results of experiments, the average distance errors between the target isocenter and its mean position were 0.71$\pm$0.19 for lateral, 0.45$\pm$0.15 for inferior-superior, 0.63$\pm$0.18 for anterior-posterior. And the maximum distance error was less than 1.3 mm. The new head fixation frame and frame mounting system were non-invasive, accurately relocatable, easy to use, very light and well tolerable by the results of phantom tests. The major advantage of using this frame mounting system is complete access to any point in the Patients cranium especially posterior direction

  • PDF

An Analysis for the Characteristics of Headward Erosion and Separation Zone due to Bed Discordance at Confluence (합류부 하상고 불일치에 의한 두부침식 및 분리구역 특성분석)

  • Choi, Heung Sik;Mo, Sun Jea;Lee, Sam Hee
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.11
    • /
    • pp.879-889
    • /
    • 2015
  • The pattern of headward erosion at tributary and the separation zone formation in a loosed bed at confluence according to the confluence angle, discharge ratio, and dredging depth ratio have been analyzed. The separation zone is defined the inside of zero velocity boundary at downstream of confluence. The limit of separation zone occurrence is presented with dredging depth ratio. The propagation length of knickpoint increases as the confluence angle, discharge ratio, and dredging depth ratio increase in general and its regression equation has been suggested. The length and width ratios of separation zone in a loosed bed increase as discharge ratio and confluence angle increase as well as in a fixed bed. The length ratio decreases and the width ratio increases as dredging depth ratio increases results in great increase of shape factor and backwater rise by the conveyance reduction at confluence. The regression equation of shape factor with confluence angle, discharge ratio, and dredging depth ratio has been suggested.

A Economic Feasibility Study of the Soybean Processing in Jeju (콩류 가공사업의 경제적 타당성 분석)

  • Ko, Seong-Bo
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.777-780
    • /
    • 2011
  • 본 연구의 목적은 농식품부 농어촌종합개발사업의 일환으로 이뤄지고 있는 제주도 한립읍 판포권역의 해거름영농조합법인의 소득기반사업인 콩류 가공(콩나물+두부)의 경제적 타당성분석을 하는 것이다. 구체적인 경제성 분석방법은 순현가와 투자수익률(내부수익률)을 이용한 기본적인 경제성분석과 주요변수들의 변화에 따른 순현가의 변화를 파악하기위한 민감도분석이다. 분석결과에 따르면, 콩나물, 두부 등 콩류 가공사업의 경제적 타당성은 순현가기준 38억 9천7백만원, 내부수익율(IRR) 기준 47.2%로 경제적 타당성이 매우 높은 것으로 나타났다. 사업규모의 변화에 대해서도, 콩나물콩의 사업규모 1,100가마를 고정시킨 상태에서 두부콩 수준의 처리규모를 3,600가마에서 1,400가마까지 처리규모를 축소해 나가도 경제적 타당성이 있고, 또한 기본시나리오에서 콩나물과 두부의 평균가격이 현재가격 대비 75% 수준이 될 때까지는 모든 할인율 수준에서 경제적 타당성이 있는 것으로 나타났다.

  • PDF

Thermal Sensitivity of the Bean Curd by Ultrasonic Irradiation (초음파 조사에 의한 두부의 열 감도)

  • 조문재;윤용현;부유천;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.503-513
    • /
    • 2004
  • In this paper, the thermal sensitivity, i .e. the temperature rise per unit acoustic power, was newly defined and proposed as a performance parameter of a tissue mimicking material. Eatable tofu (bean curd) manufactured by a factory was selected as a sample material for the experiment. The temperature changes were measured not only with the variation of ultrasonic irradiation time, acoustic power, depth from the sample surface. and the distance from the source transducer while adjusting the frequency to 8 MHz but also with the variation of frequency while acoustic power. depth from the sample surface. and the distance from the source transducer keeping constant. As a result of a consideration for the transformation of the measured temperature changes to thermal sensitivities. the thermal sensitivity was found to be sufficient to use as a Performance parameter for tissue mimicking material. The tofu as a tissue mimicking material showed the maximum thermal sensitivity at 10 MHz, as is a significant result to imply the possibility that the thermal sensitivity of real human tissue strong1y depends on the frequency.

A Study on the Optimum Design of Piled-raft Foundation Considering Pile Head Condition (말뚝두부구속조건을 고려한 말뚝지지 전면기초의 최적단면 설계)

  • Cho, Jae-Yeon;Lee, Sung-June;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.31-40
    • /
    • 2010
  • This study describes the three-dimensional behavior of pile foundations based on a numerical study. A series of numerical analyses were performed for connectivity conditions between piles and cap under vertical and lateral loadings. It is shown that a fixed connection between pile and cap is able to transfer significant bending moment through the connection and increases the pile lateral stiffness and the bending moment. Based on the results obtained, it was found that the cross sectional shear force in the raft with fixed head condition was larger than that of pinned head condition. Thus, the reinforcement of pile head and thickness of the raft also increases in fixed pile head condition. From the results, it is found that the overall behavior and cross sectional forces of pile foundations is affected significantly by the pile head conditions. Furthermore, the design of pile foundations with pinned head condition was judged to be less costly and very useful for preliminary design stages.

The Head Condition and the Installation Position of Micro-Pile to Reduce the Settlement of Adjacent Structures in Sandy Ground Tunnelling (터널 굴착시 인접구조물의 침하억제를 위한 마이크로파일의 두부조건 및 설치영역에 따른 효과)

  • 임종철;박이근;오명렬
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.5
    • /
    • pp.61-70
    • /
    • 2001
  • 도심지에서의 터널은 주로 얕은 토층비에서 이루어진다. 따라서, 본 연구에서는 토층비 1, 2 정도의 얕은 터널에 대한 터널시공을 고려하였다. 또한, 도심지 얕은 터널에서 겪게 되는 어려움 중 하나인 지상구조물의 손상을 방지하는 것이다. 이러한 경우, 구조물의 손상을 방지하기 위해 소형장비로 간단하고 저렴한 시공이 가능한 마이크로 파일공법의 채택이 주목을 받고 있다. 본 연구에서는 마이크로 파일의 설치위치와 설치각도 및 두부 고정도를 달리한 실험을 실시하여 토압 및 지표면 침하를 중심으로 그 영향을 평가하였다. 마이크로 파일의 설치위치에 있어서 거리비(A/L$_{p}$) 0.5 이내에서 침하감소면에서 대략 22%~37% 정도의 효과가 있었으며, 마이크로 파일의 두부는 파일간 서로 결속하는 것이 더 효과적임을 알 수 있었다. 이러한 경향은 토압분포에서도 마찬가지이다.다.

  • PDF

Reproducibility and reliability of head posture obtained by the outer canthus indicator (Outer Canthus Indicator를 이용한 두부 자세 기록법의 재현성)

  • Kim, Young-Jae;Sohn, Byong-Wha;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.77-86
    • /
    • 2010
  • Objective: The purposes of this study were to evaluate the reproducibility and reliability of head posture obtained by registering outer canthus as a soft tissue landmark with the Outer Canthus Indicator (OCI). Methods: Twenty-one adults with normal facial morphology were enrolled in this study (mean age $27.5\;{\pm}\;1.72$ years). To register initial head posture, height of the outer canthus from the ear rod plane was measured using OCI. Head posture was reproduced by moving the head upwards and downwards until the outer canthus was in a straight line with the indicator set at a registered height. After the head posture is reproduced by two operators after two days, lateral photographs were taken. Computerized photometric analyses of the photographs were performed. Results: The head rotations around the transverse axis were $0.69\;{\pm}\;0.43^{\circ}$, $0.98\;{\pm}\;0.65^{\circ}$ from each of the two operators. Standard errors were $0.09^{\circ}$ and $0.14^{\circ}$ each, which were similar to results from past research findings. There were no significant differences between the data from the two operators (p > 0.05). There were no correlations between the head rotation around the horizontal and vertical axes (p > 0.05). Conclusions: The present study suggests that OCI-registered head posture may minimize errors from vertical head rotation in cephalometry and photometry.